Graco 3A1334E important safety instructions Skin Injection Hazard

Page 4

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

SKIN INJECTION HAZARD

High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

Do not point dispense valve at anyone or at any part of the body.

Do not put your hand over the end of the dispense nozzle.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.

Tighten all fluid connections before operating the equipment.

Check hoses and couplings daily. Replace worn or damaged parts immediately.

FIRE AND EXPLOSION HAZARD

When flammable fluids are present in the work area, such as gasoline and windshield wiper fluid, be aware that flammable fumes can ignite or explode. To help prevent fire and explosion:

Use equipment only in well ventilated area.

Eliminate all ignition sources, such as cigarettes and portable electric lamps.

Keep work area free of debris, including rags and spilled or open containers of solvent and gasoline.

Do not plug or unplug power cords or turn lights on or off when flammable fumes are present.

Ground all equipment in the work area.

Use only grounded hoses.

If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem.

Keep a working fire extinguisher in the work area.

4

3A1334E

Image 4
Contents Related Translated Manuals Important Safety InstructionsManual Number Language Oil Pump Models PumpsGrease Pump Models Skin Injection Hazard Equipment Misuse Hazard Installation GroundingStationary Mountings Typical InstallationKey FIG Installation Guidelines Installing Outlet Hose FIGStationary Mounting Layout Pump MountingAir Line and Accessories Follow Plate Grease Models OnlyThermal Induced Pressure Relief Oil pumps only OperationThermal Relief Theory of Operation Determining Output Pressure Using the Air Regulator Pressure Relief ProcedureStart-up Is for Oil Pumps Only Relieve pressure,Operation Repair Replacing Pilot ValvesParts Description QtyRelated Oil Pump Kits Throat and Piston Seal Replacement Kit 24H853 FIGKit No Description Qty Kits 21 20Grease Pump Models 24G600 24G608 MUFFLER, 3/8Ring and Seal Replacement Kit 24H856 FIG Throat and Piston Seal Replacement Kit 24H854 FIGRelated Grease Pump Kits Kits, Oil or Grease Pump Air Valve Repair and Replacement Kits Replace Seals or Rebuild Air Valve KitsAir Valve Seal Kit 24H851 Air Valve Repair Kit 24H798Pilot Valve Replacement Kit 24H749 Problem Cause Solution TroubleshootingOil Models Replace gasket Grease Models Relieve pressureTechnical Data 31 or 51 Oil ModelsDimensions Performance Curve Oil ModelsGrease Models Performance Curve Tested with ISO 46 Hyd OilDimensions 3A1334E Graco Standard Warranty Graco Information