Graco 3A1334E important safety instructions Is for Oil Pumps Only, Relieve pressure

Page 12

Operation

Step 6 is for Oil Pumps Only:

6.The thermal relief feature of this oil pump can increase the amount of time needed to fully prime the pump when compared to pumps without a ther- mal relief feature. To minimize this effect, prime the pump before connecting it to an already primed dis- tribution system.

NOTICE

Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump acceler- ates quickly, or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with fluid, or flush it and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid system.

NOTE: A pump runaway valve can be installed on the air line to automatically shut off the pump if it starts to run too fast.

7.Read and follow the instructions supplied with each component in your system.

8.When shutting off the system and before checking or servicing, relieve pressure following pressure relief procedure, page 10.

Changing Grease Drum and Installing Follow Plate (grease models only)

1.Relieve pressure, page 10.

2.Remove drum cover by loosening thumb screws (a) (FIG. 5).

a

FIG. 5

3.Remove pump and cover from drum and place on a clean paper, cardboard, or clean shop rags. DO NOT PLACE ON SHOP FLOOR.

4.If this is an existing installation, reach into drum and pull on follow plate ring (b) to remove follow plate (FIG. 6). Place follow plate on a clean paper, card- board or clean shop rags. DO NOT PLACE ON SHOP FLOOR.

Remove drum and install new one.

b

FIG. 6

12

3A1334E

Image 12
Contents Important Safety Instructions Related Translated ManualsManual Number Language Oil Pump Models PumpsGrease Pump Models Skin Injection Hazard Equipment Misuse Hazard Installation GroundingTypical Installation Stationary MountingsKey FIG Installation Guidelines Installing Outlet Hose FIGStationary Mounting Layout Pump MountingAir Line and Accessories Follow Plate Grease Models OnlyOperation Thermal Induced Pressure Relief Oil pumps onlyThermal Relief Theory of Operation Pressure Relief Procedure Determining Output Pressure Using the Air RegulatorStart-up Is for Oil Pumps Only Relieve pressure,Operation Repair Replacing Pilot ValvesParts Description QtyThroat and Piston Seal Replacement Kit 24H853 FIG Related Oil Pump KitsKit No Description Qty Kits 21 20Grease Pump Models 24G600 24G608 MUFFLER, 3/8Throat and Piston Seal Replacement Kit 24H854 FIG Ring and Seal Replacement Kit 24H856 FIGRelated Grease Pump Kits Kits, Oil or Grease Pump Air Valve Repair and Replacement Kits Replace Seals or Rebuild Air Valve KitsAir Valve Seal Kit 24H851 Air Valve Repair Kit 24H798Pilot Valve Replacement Kit 24H749 Troubleshooting Problem Cause SolutionOil Models Replace gasket Grease Models Relieve pressureTechnical Data 31 or 51 Oil ModelsDimensions Performance Curve Oil ModelsGrease Models Performance Curve Tested with ISO 46 Hyd OilDimensions 3A1334E Graco Standard Warranty Graco Information