Greenheck Fan MSCF-FC, MSCF-BI manual Airflow

Page 8

Coil Dimensions - continued

Chilled Water • 4, 6 or 8 Row

3

C

1

A B

NOTE

With airflow from left to right, the fluid enters the coil from the bottom connection (Inlet) and exits from the top (Outlet). The other two coil connections should be capped off (cap).

Unit

Face

A

B

C

 

J

 

 

K

Size

Area

4 Row

6 Row

8 Row

4 & 6 Row

6 Row

 

 

 

15

1.6

38

24.5

11.0

10

12

14

0.75

 

1.38

 

 

 

 

 

 

 

 

 

 

 

20

2.2

38

24.5

14.0

10

12

14

0.75

 

1.38

 

 

 

 

 

 

 

 

 

 

 

25

2.7

38

24.5

16.0

10

12

14

0.88

 

1.38

30

3.2

38

24.5

18.5

10

12

14

0.88

 

1.38

 

 

 

 

 

 

 

 

 

 

 

45

4.5

50

24.5

18.5

10

12

14

0.88

 

1.38

 

 

 

 

 

 

 

 

 

 

 

50

5.2

50

24.5

21.0

10

12

14

1.38

 

1.63

 

 

 

 

 

 

 

 

 

 

 

65

6.7

50

24.5

26.0

10

12

14

1.38

 

1.63

 

 

 

 

 

 

 

 

 

 

 

85

8.6

62

24.5

26.0

10

12

14

1.38

 

1.63

 

 

 

 

 

 

 

 

 

 

 

All dimensions are in inches.

Airflow

 

 

 

(cap)

3.88

 

Outlet

.75

 

K

(cap)

 

 

 

 

 

 

Inlet

1.5 3.75

2

 

6.5

 

 

 

J

 

 

 

13.25

 

 

 

18.5

 

 

Direct Expansion (DX) • 4, 6 or 8 Row (Orifice Code 18/19)

Coil connection made inside housing.

Two inch hole is provided.

3

C

1

A

B

NOTE

With airflow from left to right, the fluid enters the coil from the center connection (Inlet) and exits from the bottom (Outlet). The other coil connections should be capped off (cap).

Unit

Face

 

 

 

 

L

 

M

N

 

P

A

B

C

 

 

 

 

 

4 & 6

 

 

Size

Area

4 Row

6 Row

8 Row

All

All

 

8 Row

 

 

 

 

 

 

 

 

 

 

Row

 

 

15

1.6

38

24.5

11.0

8.75

10.75

12.75

5.25

0.63

0.63

 

1.38

 

 

 

 

 

 

 

 

 

 

 

 

 

20

2.2

38

24.5

14.0

8.75

10.75

12.75

7.00

0.63

0.63

 

1.38

 

 

 

 

 

 

 

 

 

 

 

 

 

25

2.7

38

24.5

16.0

8.75

10.75

12.75

8.00

0.88

1.38

 

1.38

30

3.2

38

24.5

18.5

8.75

10.75

12.75

9.00

0.88

1.38

 

1.38

 

 

 

 

 

 

 

 

 

 

 

 

 

45

4.5

50

24.5

18.5

8.75

10.75

12.75

9.00

0.88

1.38

 

1.38

 

 

 

 

 

 

 

 

 

 

 

 

 

50

5.2

50

24.5

21.0

8.75

10.75

12.75

10.25

0.88

1.38

 

1.63

 

 

 

 

 

 

 

 

 

 

 

 

 

65

6.7

50

24.5

26.0

8.75

10.75

12.75

13.00

1.13

1.38

 

1.63

 

 

 

 

 

 

 

 

 

 

 

 

 

85

8.6

62

24.5

26.0

8.75

10.75

12.75

13.00

1.13

1.38

 

1.63

 

 

 

 

 

 

 

 

 

 

 

 

 

All dimensions are in inches.

Airflow

(cap)

3.88

Inlet

P

 

N Outlet

1.5 3.75 2 M

 

6.5

 

L

 

13.25

 

18.5

 

8 Model MSCF Modular Small Cabinet Fan

®

Image 8
Contents Installation, Operation and Maintenance Manual General Safety InformationInspection and Maintenance during Storage Service ClearanceReceiving UnpackingTable of Contents Unit LayoutExternal Mounting Isolation Mounting InstructionsHanging Instructions Horizontal Hanging Mscf Mounting DimensionsModular Construction Filter Sizes and Quantity Dimensional DataWeights Coil Dimensions Airflow First suction header on the entering air side Coil is circuited to the top distributor. WithAirflow from left to right, the fluid enters the coil From the center connection Inlet and exits fromSystem Start-Up Troubleshooting Symptom Possible Cause Corrective ActionStart-Up of Coil Module Hot Water and Chilled WaterSteam Coils Direct Expansion DX CoilsDrain Pan / Drain Trap TrapsControls Freezing Conditions entering air below 35FInstallation of Electric Heater optional Electrical Wiring InstructionsSizing of Supply Conductors Calculation of Line Currents ampsSequence of Operation Electric Heater Fan Maintenance Two Weeks after Start-UpEvery Three 3 Months YearlyStart-Up Documentation Coil MaintenanceDrain Pan Maintenance Maintenance Log Maintenance Log Warranty