Honeywell TE821WD user manual Thermo-Hygrometer Sensor TS33C, Features

Page 4

interconnecting wires are required between the main unit (receiver) and the remote sensors (transmitters).

Power up and test communications between all of the sensors and the main unit BEFORE mounting them outside.

For most applications alkaline batteries are acceptable where temperatures remain above 32°F (0°C).

At temperatures below 32ºF(0ºC) use lithium batteries otherwise transmission performance will be reduced or interrupted

Avoid using rechargeable batteries. (Rechargeable batteries do not provide correct power levels).

ALWAYS install batteries in the remote sensors before the main unit. (Please read batteries installation instructions in the manual for each remote sensor before installation)

Insert batteries matching the polarity in the battery compartment

Remove plastic sleeve from LCD display (if any).

During an initial setup, place the main unit close to the remote sensors.

After reception is established (all of the remote readings will appear on the main unit’s display), position the remote sensors and the main unit within the effective transmission range. Ideally they should be placed within the line of sight of the main unit. See placement tips in the user manual for each remote sensor.

Transmission range may be affected by trees, metal structures and electronic appliances.

The main unit must be placed indoors.

The effective operating range may be influenced by the surrounding building materials and how the receiver (main unit) and transmitters (sensors) are positioned.

Place the remote sensors so that they face the main unit (receiver), minimizing obstructions such as doors, walls, and furniture.

Make sure that the remote sensors are easily accessible for cleaning and maintenance.

Note: When the temperature falls below freezing, the outdoor sensor batteries may have reduced voltage and a reduced effective range. We recommend using lithium batteries at temperatures below 32°F (0°C).

IMPORTANT: We recommend cleaning the remote sensors periodically, as dirt and debris affects sensor accuracy.

Thermo-Hygrometer Sensor TS33C

FEATURES

LCD display of measured temperature and humidity

Remote data transmission to the main unit via 433 MHz signal

328 feet (100 meters) transmission range without interference

Three (3) transmission channels selection

Case can be wall mounted using built-in hanger

4

Image 4
Contents Honeywell Table of Contents Appendix City Codes SpecificationsStandard Package Contents InstallationIntroduction Before you beginFeatures Thermo-Hygrometer Sensor TS33CPlacement tips MountingRain Gauge TS906 Anemometer wind sensor TS805 Wind Vane Assembly Main UnitAligning TimeDisplay WeatherAvoid placing the main unit in the following areas Buttons and Controls Page Clock and Alarms Window Clock and Calendar Displays Initial Set upOperation and Window Selection Selecting Clock and Alarm Window Initial Settings City, Time, Date and LanguageCustom Weather Station Settings Pressure and Weather Forecast WindowPressure and Altitude Information Select Pressure and Weather Forecast WindowChanging Pressure and Altitude Paramet ers Changing or Setting Altitude Changing or Setting Sea Level PressureViewing the Sea Level Pressure History Viewing the Moon Phase History Viewing the Pressure, Temperature and Humidity Bar ChartsMoon Phas e Diagram Weather Forecast Displays Temperature and Humidity Window Temperature and Humidity DisplaySelecting Temperature and Humidity Window Viewing Temperature and Humidity for each ChannelTemperature and Dew Point Displays Temperature in Celsius or FahrenheitDisabling Temperature Alarm levels Viewing the Max/Min Channel Temperature and HumidityRain Window Selecting Rain WindowRainfall Memory Reset Setting Rain Display inches or mmSetting up Daily Rainfall Alert Enabling or Disabling Daily Rainfall AlertConfiguring Wind Display Setting Wind Speed in km/h, mph, m/s or knotsResetting the Wind Statistics Memory Viewing Wind StatisticsProgramming Time Alarms Enable/Disable Time AlarmsDisabling the Wind Alert Disable alarms Disable/Enable Snooze functionAtomic Time Reception Memory Reset Procedure MaintenanceTroubleshooting CleaningAnemometer Rain GaugeAppendix City Codes Weather forecast is inaccuratePage Specifications Power 12 AA Batteries included Battery life alkalineWind Direction Wind SpeedWeight without batteries DimensionsDeclaration of Conformity