TABLE 10

VENT & CONTROL OPTIONS

Part Number

Description

W17, W18, W24

W30, W36

W42, W48, W60, W70

CMC-14

ODT

X

X

X

CMC-15

Start Kit (230V 1-Phase)

X

X

X

CMC-23

DDC

X

X

 

CMC-24

DDC

 

 

X

CMC-28

LAC

X

X

X

BFAD-2

Barometric Fresh Air Damper - Standard

X

 

 

BOP-2

Blank Off Plate

X

 

 

 

 

 

 

 

MFAD-2

Motorized Fresh Air Damper

X

 

 

 

 

 

 

 

CRV-2

Commercial Ventilator - Spring Return

X

 

 

 

 

 

 

 

ECONWMS-E2

Economizer - School Version, Enthalpy

X

 

 

ECONWMT-E2

Economizer - Bldg. Equipment, Enthalpy

X

 

 

ECONWMT-T2

Economizer - Bldg. Equipment, DB Temp.

X

 

 

ERVF-A2

Energy Recovery Ventilator - 230 Volt

X

 

 

 

 

 

 

 

ERVF-C2

Energy Recovery Ventilator - 460 Volt

X

 

 

 

 

 

 

 

BFAD-3

Barometric Fresh Air Damper - Standard

 

X

 

 

 

 

 

 

BOP-3

Blank Off Plate

 

X

 

MFAD-3

Motorized Fresh Air Damper

 

X

 

CRVS-3

Commercial Ventilator - Spring Return

 

X

 

CRVP-3

Commercial Ventilator - Power Return

 

X

 

ECONWMS-E3

Economizer - School Version, Enthalpy

 

X

 

ECONWMT-E3

Economizer - Bldg. Equipment, Enthalpy

 

X

 

ECONWMT-T3

Economizer - Bldg. Equipment, DB Temp.

 

X

 

ERVF-A3

Energy Recovery Ventilator - 230 Volt

 

X

 

ERVF-C3

Energy Recovery Ventilator - 460 Volt

 

X

 

BFAD-5

Barometric Fresh Air Damper - Standard

 

 

X

BOP-5

Blank Off Plate

 

 

X

MFAD-5

Motorized Fresh Air Damper

 

 

X

 

 

 

 

 

CRVS-5

Commercial Ventilator - Spring Return

 

 

X

 

 

 

 

 

CRVP-5

Commercial Ventilator - Power Return

 

 

X

 

 

 

 

 

ECONWMS-E5

Economizer - School Version, Enthalpy

 

 

X

ECONWMT-E5

Economizer - Bldg. Equipment, Enthalpy

 

 

X

ECONWMT-T5

Economizer - Bldg. Equipment, DB Temp.

 

 

X

ERVF-A5

Energy Recovery Ventilator - 230 Volt

 

 

X

 

 

 

 

 

ERVF-C5

Energy Recovery Ventilator - 460 Volt

 

 

X

 

 

 

 

 

Manual

2100-581B

Page

26 of 26

Image 26
Contents Bard Manufacturing Company, Inc Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersAIR Conditioner Wall Mount Model Nomenclature Shipping DamageGeneral Fresh AIR Intake Duct WorkFilters Condensate DrainWall Mounting Information Mounting the UnitRight Unit Left UnitMounting Instructions Mounting Instructions Recommended 1 Clearance from 29 7/8 Combustible MaterialsW42A2, W42L2, W48A2, W48L2, W60A2, W60L2, W70A2, W70L2 Electric Heat Clearance Concrete Block Wall Installation Wall Mounting InstructionsCommon Wall Mounting Installations Free AIR Flow Ducted Supply No Duct Return AT UnitTAP Range Wiring Main PowerWiring LOW Voltage Wiring Safety Practices Topping OFF System ChargeThree Phase Scroll Compressor Start UP Information Important Installer NoteHigh Pressure Switch Phase MonitorCompressor Control Module Pressure Service PortsSequence of Operation FAN Blade Dimension FAN Blade Setting DimensionsFAN Blade Setting Refrigerant ChargeCooling Pressure Table DB/WBElectrical Specifications W**A Series Electrical Specifications W**L Series Maximum ESP of Operation Electric Heat only Recommended AirflowIndoor Blower Performance Electric Heat Optional Accessories Right Hand Heater Kits Circuit Breaker Wmcb & Pull Disconnect WmpdOptional Accessories Left Hand KitsVent & Control Options W17, W18, W24 W30, W36 W42, W48, W60, W70