FIGURE 2
Dimensions of Basic Unit for Architectural and Installation Requirements (Nominal)
MODEL | WIDTH | DEPTH | HEIGHT | SUPPLY | RETURN |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
(W) | (D) | (H) | A | B | C | B | E | F | G | I | J | K | L | M | N | O | P | Q | R | S | T | ||
| |||||||||||||||||||||||
W17A, L |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
W18A, L | 33.300 | 17.125 | 70.563 | 7.88 | 19.88 | 11.88 | 19.88 | 35.00 | 11.00 | 25.75 | 20.56 | 26.75 | 28.06 | 29.25 | 27.00 | 2.63 | 34.13 | 22.06 | 10.55 | 4.19 | 12.00 | 5.00 | |
W24A, L |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
W30A, L | 38.200 | 17.125 | 70.563 | 7.88 | 27.88 | 13.88 | 27.88 | 40.00 | 11.00 | 25.75 | 17.93 | 26.75 | 28.75 | 29.25 | 27.00 | 2.75 | 39.19 | 22.75 | 9.14 | 4.19 | 12.00 | 5.00 | |
W36A, L | |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
W42A, L |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
W48A, L | 42.075 | 22.432 | 84.875 | 9.88 | 29.88 | 15.88 | 29.88 | 43.88 | 13.63 | 31.66 | 30.00 | 32.68 | 26.94 | 34.69 | 32.43 | 3.37 | 42.88 | 23.88 | 10.00 | 1.44 | 16.00 | 1.88 | |
W60A, L | |||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
W70A, L |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
All dimensions are in inches. Dimensional drawings are not to scale.
W**A
RIGHT
UNIT
5.88
F
G
W
Filter Access Panel
Ventilation Air
Condenser
Air Outlet
Front View
| Built In | D |
|
|
| E |
|
| 1 |
|
|
| O |
| |
| Rain Hood | 7.88 |
|
|
|
| |
|
|
|
| 31.88 1 |
| ||
| 4° Pitch |
| 1 |
|
| ||
| Heater |
| 1.00 |
| .44 |
| |
| Access |
| 2.13 |
|
|
| |
| Panel |
| Side Wall |
| R | ||
| Electric |
| A |
| Supply Air Opening | ||
|
|
|
| ||||
| Heat |
|
| Mounting |
|
| |
| C. Breaker/ |
|
|
| Brackets |
|
|
|
|
|
| (Built In) |
| S | |
| Disconnect |
|
|
| B | ||
Access Panel |
| I |
| Top Rain |
|
| |
| (Lockable) |
|
|
|
|
| |
Hood for ERV and |
|
|
| Flashing |
| S | |
ECONWMS models |
|
|
| Shipping |
| ||
only |
|
|
|
| Location |
|
|
|
|
| C | H | Optional | Return Air Opening |
|
Standard | 3" |
| Electrical | S | |||
flush vent |
|
|
| Entrances |
|
| |
door for |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Econ. |
|
|
|
|
|
| S |
models | 11" |
|
|
|
|
| |
|
|
|
|
|
| ||
|
| K |
|
|
|
| |
Hood for | Low Voltage | Cond. |
| L |
|
| |
Electrical | J |
| M |
| S | ||
ECONWMT | Entrance | Air |
|
|
| ||
models. | High Voltage | Inlet |
|
| P |
|
|
| Electrical |
|
|
|
|
|
|
| Entrance |
|
|
|
|
| T |
Drain | N |
| Back View | Bottom Installation |
Side View |
| Q | Bracket |
jOptional top outlet (factory installed only) for W30A and W36A models only.
W**L
LEFT
UNIT
Manual | |
Page | 7 of 26 |