Bard w17a2 Mounting Instructions, Recommended 1 Clearance from 29 7/8 Combustible Materials

Page 9

Page

Manual

9 of 26

2100-581B

 

 

 

 

 

 

 

 

 

FIGURE 3B

 

 

 

 

 

 

 

 

 

 

W30A2, W30L2, W36A2, W36L2

 

 

 

 

 

 

 

 

 

 

MOUNTING INSTRUCTIONS

 

 

 

 

A

B

C

D

 

 

E

SEAL WITH BEAD

 

 

REQUIRED DIMENSIONS TO MAINTAIN

 

 

 

 

 

 

OF CAULKING ALONG

 

 

 

 

 

 

 

 

ENTIRE LENGTH OF TOP.

RAIN FLASHING

1/4" MIN. CLEARANCE FROM

28 3/8

8 3/8

5 3/8

3 11/16

17 5/8

 

 

SUPPLIED

 

COMBUSTIBLE MATERIALS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

REQUIRED DIMENSIONS TO MAINTAIN

9 7/8

4 5/8

4 7/16

16 7/8

TOP

FOAM AIR SEAL

RECOMMENDED 1" CLEARANCE FROM 29 7/8

 

 

COMBUSTIBLE MATERIALS

 

 

 

 

 

 

 

 

 

WALL STRUCTURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WALL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/4" CLEARANCE ON ALL

 

 

 

 

 

 

 

 

 

 

 

FOUR SIDES OF SUPPLY

 

 

 

 

 

 

 

 

 

 

 

AIR DUCT IS REQUIRED

 

 

 

 

 

 

 

 

 

 

 

FROM COMBUSTABLE

 

C

A

 

C

 

 

 

 

 

 

MATERIALS

D

 

Supply Opening

 

B

 

 

 

HEATER ACCESS

SUPPLY AIR

 

 

 

 

 

 

12"

 

 

 

 

 

 

 

 

PANEL

DUCT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

 

 

 

 

 

 

12"

 

 

 

 

 

 

 

 

 

 

 

12"

 

Return Opening

 

14"

 

 

 

 

RETURN AIR

 

 

 

 

 

 

OPENING

 

 

 

 

 

 

 

 

 

 

 

 

12"

 

28"

 

 

 

 

 

 

 

 

 

 

 

 

3 1

"

 

 

 

 

 

 

 

 

 

2 87 "

8

4"

 

 

7

 

 

 

NOTES:

12"

87 "

 

 

 

"

 

 

7

 

Typ.

 

 

8

 

 

IT IS RECOMMENDED THAT A BEAD OF

5 1

"

8 "

 

 

 

 

 

 

 

 

SILICONE CAULKING BE PLACED BEHIND

 

 

 

 

 

 

 

 

 

THE SIDE MOUNTING FLANGES AND UNDER

16

 

4"

 

 

 

 

 

 

 

 

TOP FLASHING AT TIME OF INSTALLATION.

 

 

 

 

 

 

 

 

 

 

 

4

11

Typ.

 

 

11

"

 

 

 

 

W*R UNIT SHOWN, W*L UNIT

16 "

 

 

 

4 16

 

 

 

 

CONTROLS AND HEATER ACCESS

 

 

 

 

 

 

 

 

 

 

 

IS ON OPPOSITE (LEFT) SIDE.

 

WallOpening andHoleLocationView

 

 

 

 

Right SideView

MIS-3158

Image 9
Contents Bard Manufacturing Company, Inc Contents For More INFORMATION, Contact These Publishers Getting Other Information and PublicationsShipping Damage GeneralAIR Conditioner Wall Mount Model Nomenclature Filters Duct WorkFresh AIR Intake Condensate DrainMounting the Unit Wall Mounting InformationLeft Unit Right UnitMounting Instructions Recommended 1 Clearance from 29 7/8 Combustible Materials Mounting InstructionsW42A2, W42L2, W48A2, W48L2, W60A2, W60L2, W70A2, W70L2 Electric Heat Clearance Wall Mounting Instructions Concrete Block Wall InstallationFree AIR Flow Ducted Supply No Duct Return AT Unit Common Wall Mounting InstallationsWiring Main Power Wiring LOW Voltage WiringTAP Range Topping OFF System Charge Safety PracticesHigh Pressure Switch Important Installer NoteThree Phase Scroll Compressor Start UP Information Phase MonitorPressure Service Ports Sequence of OperationCompressor Control Module FAN Blade Setting FAN Blade Setting DimensionsFAN Blade Dimension Refrigerant ChargeDB/WB Cooling Pressure TableElectrical Specifications W**A Series Electrical Specifications W**L Series Recommended Airflow Indoor Blower PerformanceMaximum ESP of Operation Electric Heat only Electric Heat Heater Kits Circuit Breaker Wmcb & Pull Disconnect Wmpd Optional Accessories Right HandKits Optional Accessories Left HandW17, W18, W24 W30, W36 W42, W48, W60, W70 Vent & Control Options