Bard w17a2 Shipping Damage, General, AIR Conditioner Wall Mount Model Nomenclature

Page 4

WALL MOUNT GENERAL INFORMATION

AIR CONDITIONER WALL MOUNT MODEL NOMENCLATURE

W 42 A 2 – A 10

X X X X X A

MODEL NUMBER

CAPACITY

17- 1½ Ton

18- 1½ Ton

24- 2 Ton

30- 2½ Ton

36- 3 Ton

42- 3½ Ton

48- 4 Ton

60- 5 Ton

70- 6 Ton

REVISIONS

KW

VOLTS & PHASE

A - 230/208/60/1

B - 230/208/60/3

C - 460/60/3

A- Right Hand Air Conditioner L - Left Hand Air Conditioner

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROL MODULES

 

 

 

 

 

 

 

 

 

 

 

(See Spec. Sheet S3397)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COIL OPTIONS

COLOR OPTIONS

 

X - Standard

X -

Beige (Standard)

1

- Phenolic Coated Evaporator

1

-

White

2

- Phenolic Coated Condenser

4

-

Buckeye Gray

3

- Phenolic Coated Evaporator

5

-

Desert Brown

 

 

 

and Condenser

6

-

Dark Bronze

 

 

 

 

 

 

 

 

A - Aluminum

OUTLET OPTIONS

S - Stainless Steel

X - Front (Standard)

VENTILATION OPTIONS

X- Barometric Fresh Air Damper (Standard) B - Blank-off Plate

M - Motorized Fresh Air Damper

V - Commercial Ventilator - Motorized with Exhaust

R - Energy Recovery Ventilator - Motorized with Exhaust (See Spec. Sheet S3397)

S - Economizer - School Versions, Enthalpy W - Economizer - Equipment Building, Enthalpy T - Economizer - Equipment Building, DB Temp.

T - Top Outlet (W30A, W36A Only)

FILTER OPTIONS

X- One Inch Throwaway (Standard) W - One Inch Washable

P - Two Inch Pleated

NOTE: Vent options X, B and M are without exhaust capability. May require separate field supplied barometric relief in building.

SHIPPING DAMAGE

Upon receipt of equipment, the carton should be checked for external signs of shipping damage. If damage is found, the receiving party must contact the last carrier immediately, preferably in writing, requesting inspection by the carrier’s agent.

GENERAL

The equipment covered in this manual is to be installed by trained, experienced service and installation technicians.

The refrigerant system is completely assembled and charged. All internal wiring is complete.

The unit is designed for use with or without duct work. Flanges are provided for attaching the supply and return ducts.

These instructions explain the recommended method to install the air cooled self-contained unit and the electrical wiring connections to the unit.

These instructions and any instructions packaged with any separate equipment required to make up the entire air conditioning system should be carefully read before beginning the installation. Note particularly “Starting Procedure” and any tags and/or labels attached to the equipment.

While these instructions are intended as a general recommended guide, they do not supersede any national and/or local codes in any way. Authorities having jurisdiction should be consulted before the installation is made. See Page 3 for information on codes and standards.

Size of unit for a proposed installation should be based on heat loss calculation made according to methods of Air Conditioning Contractors of America (ACCA). The air duct should be installed in accordance with the Standards of the National Fire Protection Association for the Installation of Air Conditioning and Ventilating Systems of Other Than Residence Type, NFPA No. 90A, and Residence Type Warm Air Heating and Air Conditioning Systems, NFPA No. 90B. Where local regulations are at a variance with instructions, installer should adhere to local codes.

Manual

2100-581B

Page

4 of 26

Image 4
Contents Bard Manufacturing Company, Inc Contents Getting Other Information and Publications For More INFORMATION, Contact These PublishersGeneral Shipping DamageAIR Conditioner Wall Mount Model Nomenclature Duct Work FiltersFresh AIR Intake Condensate DrainWall Mounting Information Mounting the UnitRight Unit Left UnitMounting Instructions Mounting Instructions Recommended 1 Clearance from 29 7/8 Combustible MaterialsW42A2, W42L2, W48A2, W48L2, W60A2, W60L2, W70A2, W70L2 Electric Heat Clearance Concrete Block Wall Installation Wall Mounting InstructionsCommon Wall Mounting Installations Free AIR Flow Ducted Supply No Duct Return AT UnitWiring LOW Voltage Wiring Wiring Main PowerTAP Range Safety Practices Topping OFF System ChargeImportant Installer Note High Pressure SwitchThree Phase Scroll Compressor Start UP Information Phase MonitorSequence of Operation Pressure Service PortsCompressor Control Module FAN Blade Setting Dimensions FAN Blade SettingFAN Blade Dimension Refrigerant ChargeCooling Pressure Table DB/WBElectrical Specifications W**A Series Electrical Specifications W**L Series Indoor Blower Performance Recommended AirflowMaximum ESP of Operation Electric Heat only Electric Heat Optional Accessories Right Hand Heater Kits Circuit Breaker Wmcb & Pull Disconnect WmpdOptional Accessories Left Hand KitsVent & Control Options W17, W18, W24 W30, W36 W42, W48, W60, W70