4.Remove any excess sealant on the outside of the hull to ensure smooth water flow over the paddlewheel. Warning: The O-rings must be intact and well lubricated to make a watertight seal.

5.After the sealant cures, inspect the O-rings on the valve assembly (replace if necessary) and lubricate them with the silicone lubricant supplied (see Figure 3).

6.Screw the plastic cap nut in place and hand-tightenonly. Do not over tighten.

7.Attach one pull ring to the paddlewheel insert (see Figure 5). Similarly, attach a pull ring to the blanking plug.

8.Inspect the O-rings on the paddlewheel insert (replace if necessary) and lubricate them with the silicone lubricant supplied.

9.Slide the paddlewheel insert into the housing with the arrows on the top pointing forward toward the bow. Seat it into place with a pushing twisting motion until the keys fit into the notches. The arrows on the top of the insert, the notch in the housing, and the arrow on the lip will be aligned. Be careful not to rotate the housing and disturb the sealant.

13

Image 14
Contents NX Sea Data Set Sea Data Set TH52 English Edition April Speed functions 10.1 Part specification Registering this productNX Sea Data Following material is needed Wire cutters and strippers InstallationInstallation includes 6 major steps Few do not you should considerInstalling the instrument Installing the WSI-box Example Sea Data Set TH52 English Bedding InstallingInstalling the through hull fittings Hole DrillingSea Data Set TH52 English Installation in a Cored Fiberglass Hull Checking for LeaksSea Data Set TH52 English Electrical Installation First start Initialising the instrumentHow to use the push-buttons of the Sea Data Main Subfunction Function Clear Minus Plus SETFunction overview of the Sea Data Instrument backlightSpeed sub-functions Speed functionsSpeed main-function Maximum Speed MAX Depth unit/DPTBarometric pressure unit/hPA Depth functionsBoat Speed BSP/unit Clear an alarm value Set shallow SHA and depth alarm DEASet and turn on anchor alarm ANC Silencing an alarm Turning OFF or on an alarmCustomise your display Select power on functionCancel a moved or locked sub-function Move and lock a sub-functionReturn C10 RET Calibration setting up the Sea Data instrumentCalibration of speed C10 Unit for Speed, C11 Unit KTSUnit for Depth readings, C14 Unit m Adjust Depth readings, C15 00.0 ADJDamping of Speed, C13 SEA Unit for Temp readings, C16 UnitCKey beep setting, C22 OFF KEY Adjustment of Temp reading,C17 0C TMPAdjustment of Wind Angle, C20 000 ADJ Unit for Air Pressure, C18 Unit hPAFault finding Maintenance and fault findingMaintenance General fault findingFault action Speed and distance functions No reading Wind No readingTechnical specifications WSI-box SpecificationsTechnical specifications Sea Data Waranty Sea Data Set TH52 English English Sea Data Set TH52 Nexus Marine AB