If you suspect a current in the water, drive the boat in both directions and divide trip counter distance by 2.

9.1.4Damping of Speed, C13 (SEA)

Damping of indicated boat speed through the water. Controls the response time of speed changes.

To change damping, press SET.

To select damping level, press PLUS and select from: (LOW) 1 sec, (MED) 5 sec and (MAX) 22 sec.

To store the value, press SET.

Default value is (LOW), for use in calm sea. But if the sea is rough, you may want to ”stabilise” the readout on the display, then select (MID) or (MAX).

Damping is set separately for each instrument.

9.1.5 Unit for Depth readings, C14 (Unit m)

Unit for depth. Metre (m), feet (Ft) or fathoms (FA).

Note, this is a local setting and has to be done on both Sea Data and the Wind instrument

9.1.6 Adjust Depth readings, C15 ( - 00.0 ADJ)

Calibration of the depth transducer position.

This option is used to select whether the displayed water depth is measured from the water level or the keel.

To measure from the keel, use the minus ( - ) sign.

Example: ( - 01.2 ADJ). The distance from the transducer to the keel is 1.2 m

To measure from the water surface, use the underlining character ( _ ) sign.

Example: ( _ 00.4 ADJ). The distance from the transducer to the water surface is 0.4 m.

The selected value will be subtracted or added from the measured depth.

9.1.7 Unit for Temp readings, C16 (Unit°C)

Unit for temperature. Celsius (C) or Fahrenheit (F).

27

Image 28
Contents NX Sea Data Set Sea Data Set TH52 English Edition April Speed functions 10.1 Part specification Registering this productNX Sea Data Installation Installation includes 6 major stepsFollowing material is needed Wire cutters and strippers Few do not you should considerInstalling the instrument Installing the WSI-box Example Sea Data Set TH52 English Installing Installing the through hull fittingsBedding Hole DrillingSea Data Set TH52 English Installation in a Cored Fiberglass Hull Checking for LeaksSea Data Set TH52 English Electrical Installation First start Initialising the instrumentHow to use the push-buttons of the Sea Data Main Subfunction Function Clear Minus Plus SETFunction overview of the Sea Data Instrument backlightSpeed main-function Speed functionsSpeed sub-functions Maximum Speed MAX Depth unit/DPTBoat Speed BSP/unit Depth functionsBarometric pressure unit/hPA Set and turn on anchor alarm ANC Set shallow SHA and depth alarm DEAClear an alarm value Silencing an alarm Turning OFF or on an alarmSelect power on function Cancel a moved or locked sub-functionCustomise your display Move and lock a sub-functionCalibration setting up the Sea Data instrument Calibration of speed C10Return C10 RET Unit for Speed, C11 Unit KTSAdjust Depth readings, C15 00.0 ADJ Damping of Speed, C13 SEAUnit for Depth readings, C14 Unit m Unit for Temp readings, C16 UnitCAdjustment of Temp reading,C17 0C TMP Adjustment of Wind Angle, C20 000 ADJKey beep setting, C22 OFF KEY Unit for Air Pressure, C18 Unit hPAMaintenance and fault finding MaintenanceFault finding General fault findingFault action Speed and distance functions No reading Wind No readingTechnical specifications Sea Data SpecificationsTechnical specifications WSI-box Waranty Sea Data Set TH52 English English Sea Data Set TH52 Nexus Marine AB