8 Customise your display

All sub-functions are organised in a list under the main-function. The first location in the sub-function list is an empty display. You can have your favourite sub-function moved in the same sub-function list, or copied and locked to any other page.

8.1Move and lock a sub-function

Example: In SPEED page, move and lock the sub-function depth (DPT) to the top of the sub-function list.

Select the SPEED page and find the sub-function depth (DPT). Press PAGE and SET together. All digits flash.

To lock the sub-function press SET.

Each time the SPEED page is selected, the sub-function (DPT) will be displayed at the top of the sub-function list.

8.2Copy and lock a sub-function

Example: Copy and lock the sub-function true wind speed (TWS) from DEPTH page to SPEED page.

Select DEPH page and find the sub-function (TWS).

Press PAGE and SET together.

All digits flash. To move and copy to SPEED page, press PAGE.

To lock the function, press SET.

Each time the SPEED page is selected, the sub-function (TWS) will be displayed.

The copied sub-function remains in its original location. It is only copied to a second location, where it takes the place of the empty sub-function in the list.

8.3Select power on function

The last selected combination of page and sub-functions according to your selection in

8.2is the first page the instrument will display at power up.

8.4Cancel a moved or locked sub-function

Example: To cancel the previous moved sub-function true wind speed (TWS) from SPEED page.

Select the new combination, SPEED page and sub-function (TWS).

Press PAGE and SET together.

All digits flash.

To cancel the moved sub-function, press CLEAR.

The sub-function is cancelled and the main-function still flashes.

To return to the original display, press SET.

25

Image 26
Contents NX Sea Data Set Sea Data Set TH52 English Edition April Speed functions 10.1 Part specification Registering this productNX Sea Data Following material is needed Wire cutters and strippers InstallationInstallation includes 6 major steps Few do not you should considerInstalling the instrument Installing the WSI-box Example Sea Data Set TH52 English Bedding InstallingInstalling the through hull fittings Hole DrillingSea Data Set TH52 English Installation in a Cored Fiberglass Hull Checking for LeaksSea Data Set TH52 English Electrical Installation First start Initialising the instrumentHow to use the push-buttons of the Sea Data Main Subfunction Function Clear Minus Plus SETFunction overview of the Sea Data Instrument backlightSpeed sub-functions Speed functionsSpeed main-function Maximum Speed MAX Depth unit/DPTBarometric pressure unit/hPA Depth functionsBoat Speed BSP/unit Clear an alarm value Set shallow SHA and depth alarm DEASet and turn on anchor alarm ANC Silencing an alarm Turning OFF or on an alarmCustomise your display Select power on functionCancel a moved or locked sub-function Move and lock a sub-functionReturn C10 RET Calibration setting up the Sea Data instrumentCalibration of speed C10 Unit for Speed, C11 Unit KTSUnit for Depth readings, C14 Unit m Adjust Depth readings, C15 00.0 ADJDamping of Speed, C13 SEA Unit for Temp readings, C16 UnitCKey beep setting, C22 OFF KEY Adjustment of Temp reading,C17 0C TMPAdjustment of Wind Angle, C20 000 ADJ Unit for Air Pressure, C18 Unit hPAFault finding Maintenance and fault findingMaintenance General fault findingFault action Speed and distance functions No reading Wind No readingTechnical specifications WSI-box SpecificationsTechnical specifications Sea Data Waranty Sea Data Set TH52 English English Sea Data Set TH52 Nexus Marine AB