Nexus 21 TH52 Installation includes 6 major steps, Few do not you should consider

Page 8

Sea Data Set TH52

English

2 Installation

The installation includes 6 major steps:

1. Read the installation and operation manual.

2. Plan where to install the WSI-box, transducers and instruments.

3. Run the cables.

4. Install the WSI-box, transducers and instruments.

5. Learn the functions and calibrate your system.

Before you begin drilling ... think about how you can make the installation as neat and simple as your boat will allow. Plan where to position the transducers, Server and instruments. Think about leaving space for additional instruments in the future.

A few ”do not” you should consider:

Do not cut the cables too short. Allow extra cable length at the Server so it

can be disconnected for inspection without having to disconnect all attached cables.

Do not place sealant behind the display. The instrument gasket eliminates the need for sealant.

Do not run cables in the bilge, where water can appear.

Do not run cables close to fluorescent light sources, engine or radio transmitting equipment to avoid electrical disturbances.

Do not rush, take your time. A neat installation is easy to do.

The following material is needed: Wire cutters and strippers.

Small and large Philips and small flat head screw driver. Hole saw for the instrument clearance of 63 mm (2½"). Hole saw for the transducer of 51 mm.

2.8mm drill for the WSI-box mounting screws 5 mm (1/4") drill for the mounting holes. Plastic cable ties

If you are doubtful about the installation, obtain the services of an experienced technician.

7

Image 8
Contents NX Sea Data Set Sea Data Set TH52 English Edition April Speed functions 10.1 Part specification Registering this productNX Sea Data Installation Installation includes 6 major stepsFollowing material is needed Wire cutters and strippers Few do not you should considerInstalling the instrument Installing the WSI-box Example Sea Data Set TH52 English Installing Installing the through hull fittingsBedding Hole DrillingSea Data Set TH52 English Installation in a Cored Fiberglass Hull Checking for LeaksSea Data Set TH52 English Electrical Installation First start Initialising the instrumentHow to use the push-buttons of the Sea Data Main Subfunction Function Clear Minus Plus SETFunction overview of the Sea Data Instrument backlightSpeed sub-functions Speed functionsSpeed main-function Maximum Speed MAX Depth unit/DPTBarometric pressure unit/hPA Depth functionsBoat Speed BSP/unit Clear an alarm value Set shallow SHA and depth alarm DEASet and turn on anchor alarm ANC Silencing an alarm Turning OFF or on an alarmSelect power on function Cancel a moved or locked sub-functionCustomise your display Move and lock a sub-functionCalibration setting up the Sea Data instrument Calibration of speed C10Return C10 RET Unit for Speed, C11 Unit KTSAdjust Depth readings, C15 00.0 ADJ Damping of Speed, C13 SEAUnit for Depth readings, C14 Unit m Unit for Temp readings, C16 UnitCAdjustment of Temp reading,C17 0C TMP Adjustment of Wind Angle, C20 000 ADJKey beep setting, C22 OFF KEY Unit for Air Pressure, C18 Unit hPAMaintenance and fault finding MaintenanceFault finding General fault findingFault action Speed and distance functions No reading Wind No readingTechnical specifications WSI-box SpecificationsTechnical specifications Sea Data Waranty Sea Data Set TH52 English English Sea Data Set TH52 Nexus Marine AB