Friedrich SV12, SV10, SV08 manual Unit runs but poor cooling Ineffective Cooling

Page 17

4.3 TROUBLESHOOTING GUIDE

In general, possible trouble is classified in two kinds.

The one is called Starting Failure which is caused from an electrical defect, and the other is ineffective Air Conditioning caused by a defect in the refrigeration circuit and/or improper application.

Unit runs but poor cooling.

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (Heat exchanger)

Malfunction of fan

Clogged air filter

Obstruction at air outlet

Correct above problem

Check clogging in refrigera- tion system.

Repair clogging in refrigera- tion system.

Check outdoor coil

(heat exchanger) & the fan operation.

Check for gas leakage.

Repair gas leak.

Replace unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air ; 44~50° F(7~10° C)

Check heat load increase.

Clean condenser.

Not on separate circuit.

Check inside gas pressure.

Adjustment of refrigerant charge.

Malfunction of compressor.

Replacement of compressor.

— 17—

Image 17
Contents Room Air Conditioner Service and Parts Manual Preface ContentsItems SpecificationsModels Cooling only Model FeaturesControl Locations Mechanical Parts Disassembly InstructionsFront Grille CabinetAIR Guide and Turbo FAN AIR Handling PartsCompressor Electrical PartsOverload Protector Rotary Switch Power CordCapacitor ThermostatEvaporator Refrigerating CycleCondenser Capillary Tube Pulling Vacuum Checking Installation HOW to Install the UnitWindow Requirements Installation KIT Contents Tighten the nut. See Figure Curtain Casement Window InstallationPiping System Troubleshooting GuideOutside Dimensions Unit runs but poor cooling Ineffective Cooling Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage LimitsName Plate Rating Minimum Maximum Complaint Cause Remedy Circuit Diagram Schematic DiagramQTY Description PER SETPER SET Marks Description QTYW0CZZ Exploded ViewModel SV08A10A, SV10A10A, SV12A10A Replacement Parts ListMemo Memo Use Factory Certified Parts