Friedrich SV08, SV10, SV12 manual Features, Control Locations, Cooling only Model

Page 4

1.4 FEATURES

Designed for COOLING ONLY.

Powerful and whispering cooling.

Simple installation and service.

Low air-intake, top cooled-air discharge.

Built-in adjustable THERMOSTAT

Washable one-touch filter

Compact size

Reliable and efficient rotary compressor is equipped.

1.5 CONTROL LOCATIONS

1.5.1 COOLING ONLY MODEL

• VENTILATION

The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever OPEN position.

The damper is opened and room air is exhausted.

• TEMPERATURE

Thermostat will automatically control the temperature of the room. Select a higher grade for a cooler temperature in the room. The temperature is selected by moving the knob to the desired position.

• MODE

- Turns air conditioner off.

- Med speed fan operation without cooling.

- Low speed fan operation without cooling.

- Cooling with high speed fan operation.

- Cooling with med speed fan operation.

- Cooling with low speed fan operation.

CLOSE VENT OPEN

 

 

 

Off

 

 

 

Med

High

 

 

 

Fan

Cool

 

 

 

Low

Med

 

Temperature

Warmer

Fan

Cool

Mode

Cooler

Low Cool

 

 

 

 

NOTE!

Before using the air conditioner secure the front grille with two screws enclosed with the owner’s manual.

1. Open the inlet grille downward and remove the air filter.

2. Fasten the front grille with screws.

3. Reinstall the air filter.

4. Close the inlet grille.

Inlet Grille

—4—

Image 4
Contents Room Air Conditioner Service and Parts Manual Contents PrefaceModels SpecificationsItems Control Locations FeaturesCooling only Model Disassembly Instructions Mechanical PartsFront Grille CabinetAIR Handling Parts AIR Guide and Turbo FANOverload Protector Electrical PartsCompressor Power Cord Rotary SwitchCapacitor ThermostatCondenser Refrigerating CycleEvaporator Capillary Tube Pulling Vacuum HOW to Install the Unit Checking InstallationInstallation KIT Contents Window RequirementsTighten the nut. See Figure Casement Window Installation CurtainOutside Dimensions Troubleshooting GuidePiping System Unit runs but poor cooling Ineffective Cooling Fails to Start Name Plate Rating Minimum Maximum Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Complaint Cause Remedy Schematic Diagram Circuit DiagramQTY Description PER SETDescription QTY PER SET MarksExploded View W0CZZReplacement Parts List Model SV08A10A, SV10A10A, SV12A10AMemo Memo Use Factory Certified Parts