Friedrich SV12 Disassembly Instructions, Mechanical Parts, Front Grille, Cabinet, Control BOX

Page 5

2. DISASSEMBLY INSTRUCTIONS

— Before the following disassembly, set POWER SWITCH to OFF and disconnect the power cord.

2.1 MECHANICAL PARTS

2.1.1 FRONT GRILLE

1.Open the inlet grille downward and remove the air filter.

2.Remove the screws which fasten the front grille.(See Figure 1)

3.Pull the front grille from the right side.

4.Remove the front grille.(There are 4 hooks.)

5.Re-install the components by referring to the removal procedure, above.

2.1.2 CABINET

1.After disassembling the FRONT GRILLE, remove the 6 screws which fasten the cabinet at both sides.(See Figure 2)

2.Remove the 4 screws which fasten the cabinet at back.

3.Remove the cabinet.

4.Re-install the components by referring to the removal procedure, above.

2.1.3 CONTROL BOX

1.Remove the front grille. (Refer to section 2.1.1)

2.Remove the cabinet. (Refer to section 2.1.2)

3.Remove the 1 screw which fasten the power cord. (See Figure 3)

4.Disconnect the grounding screw from the evaporator channel.

5.Remove the 2 screws which fasten the control box.(See Figure 3)

6.Remove the housing which connects motor wire in the control box.

7.Remove three leads which connect compressor.

8.Discharge the capacitor by placing a 20,000 ohm resistor across the capacitor terminals.

9.Raise the control box upward completely.

10.Re-install the components by referring to the removal procedure, above.

(Refer to the circuit diagram found on pages 21~22 in this manual and on the control box.)

Inlet Grille

Figure 1

Figure 2

Figure 3

— 5—

Image 5
Contents Room Air Conditioner Service and Parts Manual Preface ContentsItems SpecificationsModels Cooling only Model FeaturesControl Locations Mechanical Parts Disassembly InstructionsFront Grille CabinetAIR Guide and Turbo FAN AIR Handling PartsCompressor Electrical PartsOverload Protector Rotary Switch Power CordCapacitor ThermostatEvaporator Refrigerating CycleCondenser Capillary Tube Pulling Vacuum Checking Installation HOW to Install the UnitWindow Requirements Installation KIT ContentsTighten the nut. See Figure Curtain Casement Window InstallationPiping System Troubleshooting GuideOutside Dimensions Unit runs but poor cooling Ineffective Cooling Fails to Start Complaint Cause Remedy Room AIR Conditioner Voltage LimitsName Plate Rating Minimum Maximum Complaint Cause Remedy Circuit Diagram Schematic DiagramQTY Description PER SETPER SET Marks Description QTYW0CZZ Exploded ViewModel SV08A10A, SV10A10A, SV12A10A Replacement Parts ListMemo Memo Use Factory Certified Parts