A-1

 

INSTALLATION

 

A-1

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS – SP 170-I /UWW-170 (Above Code 10600)

INPUT – SINGLE PHASE ONLY

Standard Voltage/Frequency

230V/50/60Hz

Input Current

20 Amps – Rated Output

Duty Cycle

25%

60%

100%

Welding Current Range

Rated DC Output: 30 – 170 amps

RATED OUTPUT

Amps

125

85

70

OUTPUT

Maximum Open Circuit Voltage

33

Volts at Rated Amperes

20.25

18.25

17.50

Wire Speed Range

50-400IPM (1.3-10.2m/min)

RECOMMENDED INPUT CABLE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

Fuse or

 

 

 

 

Output Mode

Input Voltage

Breaker Size

Input Amps

Power Cord

 

 

 

 

 

 

 

 

 

RATED

230V/50/60Hz

30 Super Lag

20

16 Amp, 230V,

 

 

 

 

 

 

Two-Prong International

 

 

 

 

 

 

Cord Set (Supplied)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TECHNICAL SPECIFICATIONS – SP 170-I /UWW-170 (Below Code 10600)

INPUT – SINGLE PHASE ONLY

Standard Voltage/Frequency

220V/50/60Hz

Input Current

22 Amps – Rated Output

Duty Cycle

25%

60%

100%

Welding Current Range

Rated DC Output: 30 – 170 amps

RATED OUTPUT

Amps

120

100

75

OUTPUT

Maximum Open Circuit Voltage

32

Volts at Rated Amperes

20

19

18

Wire Speed Range

50-400IPM (1.3-10.2m/min)

RECOMMENDED INPUT CABLE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

Fuse or

 

 

 

 

Output Mode

Input Voltage

Breaker Size

Input Amps

Power Cord

 

 

 

 

 

 

 

 

 

RATED

220V/50/60Hz

30 Super Lag

22/20

16 Amp, 220V,

 

 

 

 

 

 

Two-Prong International

 

 

 

 

 

 

Cord Set (Supplied)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

Height

Width

Depth

Weight

12.0 in

9.75 in

16.5 in

57 Ibs

305 mm

248 mm

419 mm

25.9 kg

 

 

 

 

The SP170-I / UWW-170 is designed for industrial and professional use in accordance with the standard EN 60974-1 / IEC 974-1.

SP-170-I

Image 8
Contents SP 170-I and UWW-170 Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Installation 2INSTALLATIONA-2 Safety PrecautionsIdentify and Locate Components Electric Shock can killSelect Suitable Location LimitationsOutput Connections StackingGUN Installation Work Cable InstallationConnecting Gun Cable to the SP GAS ConnectionPower Input Cable Input ConnectionsLine Cord Connection 230 50/60Design Features Advantages Operational Features and ControlsOperation General DescriptionControls and Settings Welding CapabilityWire Loading Friction Brake AdjustmentWelding Operations Sequence of OperationFigure B.4 Making a Weld Cleaning Tip And NozzleProcess Guidelines Overload Protection Changing Machine Over to Feed Other Wire SizesWelding with Gmaw MIG Learning to Weld Learning to WeldARC-WELDING Circuit SELF-SHIELDED Fcaw Welding ARCFor Gmaw MIG Process Gmaw MIG Welding ARCProcess Selection Common Metals Joint Types and PositionsFor Fcaw Innershield Process Butt WeldsFillet Welds Welding In The Vertical PositionPenetration Machine SET UP for the SELF-SHIELDED Fcaw Process Welding Techniques for the SELF- Shielded Fcaw ProcessVertical-down Welding Correct Welding PositionCorrect Electrical Stickout ESO Correct Welding SpeedHelpful Hints PracticeMachine SET UP for the Gmaw MIG Process Welding Techniques for the Gmaw MIG ProcessFor the SP 170-I, use the following Troubleshooting Welds To Eliminate a Ropy Convex Bead in order of importanceTo Correct Poor Penetration in order of impor- tance To Eliminate Stubbing* in order of importanceProper Gun Handling Drive Roll Orientation Application ChartOutput Polarity Accessories Optional AccessoriesK464 .035 0.9 mm Innershield Welding Kit K491 .045 1.2 mm Innershield Welding KitReplacement Parts Innershield Fcaw ConversionRoutine Maintenance MaintenanceMaintenance Safety Precautions GUN and Cable Maintenance Configuration of Components in Wire Feeding SystemGun Cable Cleaning Contact Tip Cable Liner Drive RollChanging Drive Roll UWW-170 only Component Replacement ProceduresChanging Drive Roll SP 170-I only Changing Liner Fully seat the liner bushing into the conGUN Handle Parts black trigger GUN Handle Parts red triggerTroubleshooting HOW to USE Troubleshooting GuideProblems Possible Areas Symptoms Misadjustments Recommended Course of ActionGAS Flow Problems Welding Problems Wiring WiringPage How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? $700.00Precaucion Warnung