Lincoln Electric TIG 375 manual Controls and Settings, Figure B.1 Control Panel

Page 18

B-3

OPERATION

B-3

 

 

 

CONTROLS AND SETTINGS

The Front Control Panel contains the knobs and switches necessary for adjusting the operation of the Precision TIG 375, with function indicator lights and an electronic display for volts and amps. The components are described below:

FIGURE B.1 - CONTROL PANEL

7

7a

8

9

5

6

3

4

12

13

14

15

16

17

1

2

1.POWER SWITCH

2.POLARITY SWITCH

3.MODE SWITCH

4.AC BALANCE CONTROL

5.LOCAL/REMOTE CURRENT CONTROL SWITCH

6.MAXIMUM OUTPUT CONTROL

7.MINIMUM OUTPUT CONTROL AND DISPLAY SWITCH

9

7a . MENU BUTTON AND DISPLAY

SWITCH

 

8. DIGITAL METER AND DISPLAY

 

SWITCH

 

9. POSTFLOW TIME

10

10. THERMAL SHUTDOWN LIGHT

11. REMOTE RECEPTACLE

12.TRIGGER SWITCH

13.PULSE / SPOT MODE SWITCH

14.PULSE FREQUENCY CONTROL

15.PULSE % ON TIME CONTROL

16.PULSE BACKGROUND CURRENT CONTROL

17.DOWNSLOPE TIME

18.INTERNAL SETUP SELECTIONS (NOT SHOWN)INSIDE PANEL.

11

19. HIGH FREQUENCY INTENSITY

CONTROL (NOT SHOWN, LOCATION

 

ONLY)ON SIDE OF MACHINE.

19

1.POWER SWITCH - Input line switch turns input power ON or OFF, as indicated by the on or off sta- tus of the front panel displays.

2.POLARITY SWITCH – The 3-position rotary power switch has detente positions for DC-, AC and DC+ selections for the Electrode output welding polarity.

3.MODE SWITCH – The mode switch allows vertical- ly positioned selection of the two machine welding modes. The selected mode is indicated by a lit col- ored panel light which permits viewing the machine setting from a distance:

3.a STICK mode (Top position) –Red panel light

WARNING

The CC Stick mode may be used for general pur- pose stick welding (SMAW ) within the capacity of the machine. The capacity is too limited for arc air carbon (AAC) gouging.

In this mode; the output terminals are activated electrically HOT, gas flow is not activated and HOT START and ARC FORCE levels are fixed, or Advanced Panel selectable (See Section B-7 ), with no front panel adjustment.

3.b TIG mode (Bottom position) – No panel light.

When the Polarity Switch is set to AC, the TIG mode provides continuous high frequency to stabi- lize the arc for AC TIG welding.

ELECTRIC SHOCK can kill.

When the Power Source is ON in STICK mode the Electrode circuits of both the Stick and TIG torch cables are electrically HOT to Work.

------------------------------------------------------------------------

Hi-Freq. turns on after preflow time with the arc start switch closure, and turns off when the arc goes out* after the arc start switch opens.

*Arc voltage and current are sensed to determine if the arc is established or out.

PRECISION TIG 375

Image 18
Contents Safety Depends on You Precision TIGSafety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Duty Cycle-Applications Volts at Rated Amperes Amps InstallationRated Input Single Phase only Precision TIGTemperature Ranges Recommended Input Wire and Fuse SizesPhysical Dimensions Additional Output CapacitySafety Precautions Input and Grounding Connections Output CABLES, Connections and Limitations Work Cable ConnectionStick Electrode Cable Connection TIG Torch Connection Figure A.2Auxiliary Power Connections Figure A.3Robotic Interface Connection Figure A.4Pipe Thawing OperationProduct Description Welding SparksProcess Limitations Recommended Processes and EquipmentRecommended Processes Equipment LimitationsControls and Settings Figure B.1 Control PanelOperation TIG Mode Menu DisplayDo not USE 4-STEP if Using AN Amptrol Remote Advanced Panel ControlsOperation Internal SET UP Controls TIG Welding FeaturesStick Welding Features Figure B.3 Figure B.4 TIG Weld Cycle Chart Setup Guidelines for TIG Welding With AN AmptrolFigure B.6 Making a TIG Weld with AN Amptrol Smaw ProcessGtaw Process Field Installed Options AccessoriesFactory Installed Options Optional EquipmentRoutine and Periodic Maintenance MaintenanceSafety Precautions Overload ProtectionSpark GAP Adjustment Service ProceduresComponent Access UNDER-COOLER ServiceTroubleshooting HOW to USE Troubleshooting GuideSymptoms Output ProblemsCourse of Action Meter Problems GAS ProblemsHI-FREQ Problems Preset & Output Control Problems Stick Welding Problems TIG Welding ProblemsTIG Problems Wiring Diagram Wiring Diagram Dimension Print K2622-1 Domestic Precaucion Aviso DE