OPERATION | ||
|
|
|
•In
1.Closing switch starts preflow, then arc starts at Minimum (Start) setting level (See Item 7). If the trigger is maintained closed after preflow time the output remains at the Start level until it is released.
2.Opening switch initiates fixed (0.5 sec.) ramp time from Start setting level to Weld setting.
3.Reclosing switch initiates Downslope ramp time setting (See item 17) from Weld setting down to the
4.Reopening switch after Downslope time holds
Note: See Section
13.PULSE / SPOT MODE SWITCH – Turns on the Pulse Mode as indicated by the Green panel light turning on.
•PULSE ON provides a Peak current level set by REMOTE and/or LOCAL control of the output cur- rent (See Item 5), for a time determined by the Pulse Frequency Control setting (See Item 14) and the % ON Time (See Item 15). The balance of the cycle time is at the Background Current level (See Item 16). The Green panel light blinks at the pulse frequency and time setting rate.
•Pulsing begins after upslope when the output cur- rent rises above the Background Current level and ends when the output current drops below this level.
•SPOT ON mode provides the peak current level set by the Maximum Output Control for a time deter- mined by the SPOT TIME control (see below). The red panel light is on for Spot mode.
14.PULSE FREQUENCY CONTROL – This knob is used to set the Pulse Frequency over the peak pulse range of about 0.1 pps to 20 pps. (One pulse cycle time = 1/pps = 10 to .05 sec. range.)
15.PULSE % ON / SPOT TIME CONTROL
•% ON TIME sets duration of the peak current as a percentage (5% to 95% on white scale) of one pulse cycle. The balance of the cycle time will be at the Background Current setting.(See Item 16)
•SPOT TIME sets the duration of the Spot pulse (0.5 to 5.0 seconds on red scale).
16.PULSE BACKGROUND CURRENT CONTROL – This knob controls the level of the Background Current as a percentage
6)down to the Minimum Output setting (See Item
17.DOWNSLOPE TIME– This knob is used to set the time, over the range of zero to about 10 seconds, to ramp down from weld setting to
•If the arc goes out after the Downslope time is initi- ated, the Downslope time is interrupted and the Postflow time is initiated. This prevents
•When using an Amptrol remote control, where the downslope is controlled by the operator down to the
18.HIGH FREQUENCY INTENSITY CONTROL (NOT SHOWN)– Allows setting the lowest intensity which still gives good TIG arc starting with minimized Radio Frequency Interference (RFI). Control knob is located on a recessed panel near the easy acces- sible spark gap side panel. As shipped, the control is set to minimum.