ACCESSORIES | ||
| How to use Table C.1. |
|
Determine which Kit No. is to be used. Locate that Kit No. in the left hand vertical column.
Scan horizontally to determine which
TABLE C.1
LN-25™ OPTION CHART
O = CANNOT BE USED WITH X = REQUIRED ➀ = REQUIRES ONE OF THESE | + = INCLUDED WITH | |||||||||||||||||
|
|
|
|
|
|
|
| SEE TEXT |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
KIT NO. |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| K428 | K446 | K449 | K432 | K433 | K444 | K461 | K625 | K626 | K627 | ||||||||
Solenoid | X | + | + |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Kit |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote Output | ➀ | ➀ | O |
| X | X | O | O | O | O | O |
| O |
|
|
|
| |
Control Module |
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K432 | Remote |
|
|
| X |
| X |
|
|
|
|
|
|
|
|
|
|
|
Control Cable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K433 | 115VAC |
|
|
| X | X |
|
|
|
|
|
|
|
|
|
|
|
|
Power Source |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Remote Box |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Gas Flow |
|
| ➀ | ➀ |
|
| ➀ |
|
|
| ➀ |
| ➀ |
|
|
|
| |
Timer Kit |
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K439 | 50 Ft. |
|
|
|
| X |
|
|
|
|
|
|
|
|
|
|
|
|
Ext. Cable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Contactor Kit |
|
| + | O |
|
|
|
|
|
| O |
| O |
|
|
|
| |
Contactor Kit |
|
| + | O |
|
|
|
|
|
| O |
| O |
|
|
|
| |
Codes 10500,10558 |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Contactor Kit |
|
| + | O |
|
|
|
|
|
| O |
| O |
|
|
|
| |
| Codes 11144 & Above |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K444 | Remote for Power | ➀ | ➀ | ➀ | O |
|
|
|
|
|
| O |
| O |
|
|
|
|
Source w/Terminal Strip |
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote for Power | ➀ | ➀ | ➀ | O |
|
|
|
|
|
| O |
| O |
|
|
|
| |
Source w/6 Pin Amphenol |
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Remote for Power | ➀ | ➀ | ➀ | O |
|
|
|
|
|
| O |
| O |
|
|
|
| |
Source w/14 Pin Amphenol |
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
42VAC Remote | ➀ | ➀ | O | O |
|
| O | O | O | O | O |
|
| ➀ | ➀ | ➀ | ||
Output Control Module |
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K625 | 500 Amp Cable /w Stud- |
|
|
|
|
|
|
|
|
|
|
|
| X |
|
|
|
|
Type Output Terminals |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K626 | 350 Amp Cable /w Stud- |
|
|
|
|
|
|
|
|
|
|
|
| X |
|
|
|
|
Type Output Terminals |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K627 | 400 Amp Cable /w Twist- |
|
|
|
|
|
|
|
|
|
|
|
| X |
|
|
|
|
Mate™ Type Terminals |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Pulse Power™ | ➀ | ➀ | O | O |
|
| O | O | O | O |
| X | O |
|
|
|
| |
Adapter Kit |
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
K461 | Pulse Power™ |
|
|
|
|
|
|
|
|
|
| X |
|
|
|
|
|
|
Control Cable |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IMPORTANT SAFETY NOTE: This wire feeder provides “COLD” electrode when gun trigger is released if equipped with