TROUBLESHOOTING AND REPAIR |
GAS SOLENOID VALVE AND SOLENOID PC BOARD TEST (continued)
FIGURE F.4 – PC BOARD FOR K430-1 GAS SOLENOID KIT.
| 512 |
624A | 621 |
621 | J11 |
PC BOARD FOR K430 GAS SOLENOID KIT.
M15202
606
624A | 512 | 621 |
|
|
Return to Section TOC
Return to Master TOC
2.Check for the presence of the DC voltage applied from lead 624A(+) to lead
3.Check for the presence of 12 VDC from lead 512(+) to lead
4.Check for the presence of 10 VDC from lead 606(+) to lead
5.If the above voltage readings are good and the solenoid valve is functional, the Solenoid PC Board may be faulty.
6.If the above voltage checks are not correct, the control board, contactor board (if used), remote control board (if used) and/or wiring harness may be faulty. Refer to the wiring diagrams in the Electrical Diagrams Section.
The appropriate jumper plugs may be used to isolate and check suspect contactor or remote control boards.