TROUBLESHOOTING AND REPAIR |
GAS SOLENOID VALVE AND CONTROL PC BOARD TEST
(FOR CODES ABOVE 10500 ONLY) (continued)
FIGURE F.8. – CONTROL PC BOARD.
G3425
667 | 555 | 691 |
621
J1 | J3 | J4 | J2 |
500 | 512 | 690 |
|
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
2.Check for the presence of the DC voltage applied from plug J1 pin 1 (667+) to plug J1 pin 3
3.Check for the presence of 5 to 6 VDC from lead 690(+) to lead
4.If the above voltage reading is not correct at the solenoid valve, check for 5 to 6VDC at plug J2 pin 3 lead 690(+) & pin 6 lead 691
5.If the above voltage check is not correct, the control board may be faulty. Refer to the wiring diagrams in the Electrical Diagrams Section.
The appropriate jumper plugs may be used to isolate and check suspect contactor or remote control boards
NOTE: Machines with Codes above 10100 that have been upgraged to the