MAINTENANCE

D-2

 

 

 

CONTROL BOX

 

 

SAFETY PRECAUTIONS

 

 

 

 

 

 

 

 

Every six months open and inspect the control sec-

 

 

 

 

WARNING

 

 

 

 

 

 

tion. The accumulated dirt should be gently blown off

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC SHOCK can kill.

 

all of the electrical components. Be sure the air that

 

 

 

 

is being used is dry. Check that lead plugs are secure

 

 

 

• Do not operate with covers

 

in their receptacles.

 

 

 

 

 

 

 

removed.

WIRE DRIVE MOTOR AND GEARBOX

Return to Section TOC

Return to Master TOC

Turn off power source before installing or servicing.

Do not touch electrically hot parts.

Turn the input power to the welding power source off at the fuse box before working in the terminal strip.

Only qualified personnel should install, use or service this equipment.

Every year examine the gearbox. Paint the gear teeth with molydisulfide filled grease. Do not use a graphite grease.

Check the motor brushes. Replace if they are worn down to 14’’ or less. When ordering feed motor brushes, give all information from the motor nameplate.

GUN AND CABLE MAINTENANCE

See IM manual provided with the gun and cable as- sembly.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

ROUTINE MAINTENANCE

DRIVE ROLLS AND GUIDE TUBES

After feeding every coil of wire, inspect the drive roll section. Clean it as necessary. Do not use a solvent for cleaning the idle roll because it may wash the lu - bricant out of the bearing. The drive roll, idle roll and guide tubes are stamped with the wire sizes they will feed. If a wire size other than that stamped on the rolls is to be used, the rolls and guide tubes must be changed.

The drive rolls for .035 through .052 cored electrode and 116 through 564 electrode have a double set of teeth so they can be reversed for additional life. Drive rolls for .023 through .052 solid electrode and aluminum sizes have no teeth but use two grooves so they also can be reversed for additional life.

See Wire Feed Drive Roll and Guide Tube Kits Sec - tion for roll changing instructions.

WIRE REEL SPINDLE

No routine maintenance required. Do not lubricate spindle.

CIRCUIT PROTECTION AND AUTOMATIC SHUTDOWN

CONTROL PC BOARD FUSE

On G1757-6 (or higher part no.) PC boards the 18 amp fuse was replaced with electronic protection for trigger circuit faults to electrode circuit.

On G1757-2 through -5 part no. PC boards, the 18 amp fuse interrupts the 500A lead to the trigger switch. On G1757- 1 PC boards a 5 amp fuse was used to interrupt the 667 lead. The LN-25™ will not operate if the fuse is blown.

AUTOMATIC PROTECTION SHUTDOWN

(See Automatic Protection Shutdown Section.)

ADJUSTING SPEED

SENSOR MODULE

The LN-25™ Speed Sensor Module is a three lead Hall Effect switch device encased in an externally threaded housing which is screwed into a mounting plate on the motor side of the wire drive gearbox.

LN-25™

Image 30
Contents Semiautomatic Wire Feeder Safety California Proposition 65 WarningsElectric Shock can kill Fumes and GasesCan be dangerous Welding and Cutting Sparks can Cause fire or explosion Cylinder may explode if damagedIii Précautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Table of Contents Installation SectionWire Feed Speed InstallationTechnical Specifications LN-25 CurrentrentSafety Precautions Power Source ConnectionWith CV Adapter INVERTEC, CV300 and Other Newer Lincoln Power SourcesGUN Cable Connection to Feeder For GMA GUN and CablesElectrode Cable Connection Wire Feed Drive Roll and Guide Tube KitsWeld Cable Connection Work Cable ConnectionLN-25 Operation Section Operation Welding CapabilityRead and Understand Entire Section Before Operating Machine Wire Speed Dial and Range Switch Electrode Polarity SwitchWire Feed Mode Switch LN-25 Instruments ControlsAWG GAS Post PRE-FLOW Timers OptionalWork Clip Lead Remote ARC Voltage Control OptionalMounting 22 to 30 LB READI-REELCOILS Sequence of OperationLoading Electrode Mounting 10 to 30 LB SpoolsGrooves READI-REEL Inside Cage Wires Loading Wire DriveIdle Roll Pressure Setting 6OPERATIONB-6Setting ARC Sensing Wire Feed Speed CC Mode Presetting Wire Feed SpeedSetting Constant Wire Feed Speed CV Mode Minimum Arc VoltsFigure B.4 VV CC Wire Speed Setting Making a WeldProcedure AT END of Coil WeldingCylinder may explode if damaged Circuit Protection and Automatic Shutdown Overvoltage ShutdownMotor Overload Shutdown Accessories Section Accessories Section CHow to use Table C.1 AccessoriesLN-25 Option Chart Table C.1Optional Accessories K434-1 GAS Flow Timer KITGAS Solenoid KIT K430-2 for Codes Remote Output Control Options and Control Cable Assemblies K433 Power Source Remote BOXK432 Remote Control Cable Assembly LN-25 Contactor KIT K443-1 for CodesK624-1 42V Remote Output Control Module K439 Remote Extension Cable AssemblyK625, K626, K627 Remote Control Cable Assembly K444, K444-1 or K444-2 Remote Voltage Control KITStyle a Connector Must be Insulated in this AreaTo GUN Switch Connect Leads to Pins a and C DIA. HoleMaintenance Section Maintenance Routine MaintenanceAdjusting Speed Sensor Module Calibration of LN-25 Wire Speed Dial LN-25 Figure E.1 Theory of Operation Block Diagram Theory of Operation SectionGeneral Description Input Power CircuitTheory of Operation Control Circuit OperationFeedback and Control Circuits Trigger CircuitGAS Solenoid Optional CircuitsContactor Later ModelsProtective Devices Circuits Control PC Board FusesLN-25 Troubleshooting and Repair Section 2TROUBLESHOOTING and REPAIRF-2 HOW to USE Troubleshooting GuideTroubleshooting and Repair PC Board Troubleshooting ProceduresFeeding Problems Feeding Problems Hall Effect Materials Needed GAS Solenoid Valve and Solenoid PC Board TestTest Description For Codes below 10500 onlyCase Door Test ProcedureScrew Wire Reel Retaining Collar GAS Solenoid ValveFigure F.2 Solenoid Leads Troubleshooting and Repair 624A 621 J11 GAS Solenoid Valve and Solenoid PC Board Test512 PC Board for K430 GAS Solenoid KITLN-25 GAS Solenoid Valve and Control PC Board Test For Codes Above 10500 onlyFor Codes Above 10500 only Figure F.5 Control BOX Cover RemovalSolenoid Leads Figure F.6. Solenoid LeadsFigure F.7. Applied Voltage Polarity Control PC Board Solenoid Circuitry TestG3425 667 555 691 621 500 512 690LN-25 Hall Effect Module Test Hall Effect Module Test G2196 539 541 500539 G1757 Figure F.11 Control PC Board Codes Above LN-25 Wire Drive Motor Test Drive Motor Lead IN-LINE Connector Hall Effect Module Contactor & Contactor PC Board Test Contactor Test Procedure Contactor & Contactor PC Board TestS20963 Contactor Coil Leads28TROUBLESHOOTING and Repair F-28 Contactor PC Board Test667 J14 LN-25 Contactor PC Board Replacement Tools RequiredContactor PC Board Replacement Repair Procedure33TROUBLESHOOTING and Repair F-33 Figure F.17 Control PC Board Replacement Control PC Board Replacement Figure F.21. Control PC Board Codes 9812 and belowFigure F.22. Plug Locations for L12253- Control Board J14Figure F.24. Control Board Replacement PC Board Screw Contactor Replacement For Codes below40TROUBLESHOOTING and Repair F-40 Contactor ReplacementFor Codes Above Figure F.26 Phillips Head Screwdriver Wrench Pliers GAS Solenoid Valve AND/OR Solenoid PC Board if Present ReplacementPurge Switch Leads Solenoid Plug J11 GAS SolenoidFigure F.29. Solenoid Assembly Wiring Codes 9812 and below Figure F.31. GAS Solenoid Assembly for Earlier Codes Phillips Head Screwdriver Wrench Slot Head Screwdriver Hall Effect Module 48TROUBLESHOOTING and Repair F-48Drive Motor and Gearbox Replacement and Access to Mylar Insulation Electrode CableG1757 Figure F.34. Drive Motor Replacement Retest After Repair LN-25 Electrical Diagrams Table of Contents Electrical Diagrams SectionWiring Diagram Above Code 11140 G4679 Optional 42 Volt Remote Output ControlWiring Diagram Code 10556 Thru 10500 L10925 Wiring Diagram Code 10100 Thru 10500 L9644 Wiring Diagram below Code 9900 L7545 Schematic Complete Machine Codes Above 11140 G5366 LN-25 Across the ARC ModelSchematic Complete Machine below Code 9900 only G1833 Schematic Control PC BD Above Code 11140 G4616-5 Schematic Control PC BD Code 10556 Thru 10558 G3424-3 Schematic Control PC BD Code 10100 Thru 10500 G2194 PC Board Assembly Control Abovr Code 11140 L12253-3 L12253L12253-3 PC Board Assembly Control Code 10556 Thru 10558 G3425-3 G3425PC Board Assembly Control Code 10100 Thru 10500 G2196-1 PC Board Assembly Control below Code 9900 G1757-6 LN-25 ControlSchematic Contactor PC BD Above Code 10500 M10965 ContactorSchematic Contactor PC BD Code 10100 Thru 10500 M17621 Electrical Diagrams Electrical Diagrams PC Board Assembly Contactor Above Code 10500 L10863-1 L10863PC Board Assembly Contactor Code 10100 Thru 10500 L9670-1 PC Board Assembly Contactor below Code 9900 L9185-2