Lincoln Electric SVM132-A service manual Operating Schematic, 1CR Wire Feed Motor Field

Page 94

Return to Section TOC

Return to Master TOC

G-4

ELECTRICAL DIAGRAMS

OPERATING SCHEMATIC

 

75

 

 

 

 

CASE

 

METER KIT RECEPTACLE

 

N.A. JUMPER PLUG IS REMOVED AND CONNECTOR "B" IS PLUGGED INTO

 

R20

 

 

 

GROUNDING

 

 

 

 

OPTIONAL BURNBACK P.C. BOARD. SEE S15123 FOR OPERATING

76

 

 

 

SCREW

 

GND 541 543

21

567

568

SCHEMATIC.

77

 

GND LEAD

THERMAL

 

 

 

 

 

 

 

N.B. RESISTOR USED ON CODES 9090 AND BELOW ONLY. FOR CODES

 

 

 

 

 

 

 

 

ABOVE 9090 THE GROUNDING LEAD PROTECTOR CONNECTS

5 AMP CIRCUIT

CIRCUIT

D103

D104

R118

 

 

 

 

PROTECTOR

 

 

 

 

DIRECTLY TO THE CASE GROUNDING SCREW.

BREAKER

BREAKERS

 

 

 

 

 

 

 

32A

SWITCH

 

32A

 

 

R126

 

 

 

568

 

 

 

 

 

 

 

 

G-4

Return to Section TOC

Return to Master TOC

32

 

 

N.A.

5

32A

531

4

4

2

504

3

 

6502

1 2

TO POWER SOURCE TO OPERATE CONTACTOR

2

1CR

504

4

GND LEAD PROTECTOR COIL

GND

.1

N.B.

TP201

C204 D203

525A

D205

523 536

R202

 

D201

1CR D202

 

 

525

 

528

 

 

 

 

 

 

TH1

S1

 

2CR

 

 

 

 

 

524

 

 

529

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

683

522

T1

526

C205

S2

R205

D204

1CR

C202

SCR 201

R206

R204

C201

682

S3

 

 

627

C203

(W)

C206

R203

(R)

 

 

 

 

626

 

 

R201

 

F201

531

732A

1CR

WIRE

FEED

MOTOR FIELD

C107

C108

PT101 PT101

SCR101 SCR102

7

C109

D107

TP101

 

 

D105

D106

 

 

 

 

 

 

 

 

 

 

 

 

R127

R123

 

DZ101

 

541

 

R111

 

 

 

(B)

 

 

 

 

 

R105

R109

(U)

 

 

 

 

C111

 

R108

 

 

 

C112

 

R107

 

 

QU101

R106

PT101

C106

C105

R124

D101

R113

D102

R112

 

R129

D113

 

C103

 

R125

D114

D108

539

R128

S

F

Q103

 

D110

 

D111

 

 

C104

R121

R119

R120

R102

635

C113

 

R116

Q101

 

R114

R115

D109

Q102

R122

D112

L101

B

 

S304

 

 

 

 

 

 

A

 

R309

PT301

 

R117

 

 

C303

 

 

CV

VV

 

 

 

 

 

 

C306

 

 

R103

 

 

 

C305

 

C101

 

Q302

 

 

 

 

 

 

 

 

637

 

 

 

R101

 

DZ302

 

 

631

 

 

 

 

R9

C110

 

 

C304

632 R110

634

C102

 

R310

 

 

 

 

 

 

R306

 

R302

 

R305

R307

R308

QU301

PT301

C302

DZ301

R303 C301

R301

Q301

R304

C307

D301

D302

D303

D304

TP301

567

TO

GUN

CABLE

LN-8

SHUNT

ARC

VOLTAGE

TO

POWER

SOURCE

R311 21

31

 

R4

531

 

 

 

CASE GROUNDING SCREW

539

VARIABLE VOLTAGE CONTROL CIRCUIT TO RIGHT OF THIS LINE. TO OPERATE LN-8 WHEN THIS CIRCUIT IS NOT INSTALLED IN UNIT,

CONTROL CIRCUIT (BOARD #1)

C101 1MFD

L101 5.6MH

RELAY CIRCUIT (BOARD #2)

C201 50MFD

POINT "A" TO "B" IS JUMPERED.

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

C102

2MFD

 

 

Q101

2N4125

C103

39MFD ~10%

Q102

2N4123

C104

4.7MFD

 

Q103

2N5815

C105

.10MFD

 

QU101

2N6027

C106, C110,C111

.02 MFD

TP101

TRANSIENT PROTECTION

C112, C113

 

 

SCR101

12A 400V

C107, C108

.047MFD

SCR102

12A 400V

C109

.005MFD

 

 

PT101 1:1:1 PULSE TRANSFORMER

D101

1A.

R101

6.8K

R116

10K

 

 

D102

1A.

R102

2K

TRIMMER

R117

22K

 

 

D103

1A.

R103

10K

 

R118

4.7K

4W

D104

1A.

R105

4.7K

R119

27K

 

 

D105

16A.

R106

4.7K

R120

15K

 

 

D106

16A.

R107

15

 

R121

1.5K

 

D107

16A.

R108

33K

 

R122

10K

 

 

D108

1A.

R109

33K

 

R123

.25

 

7W

D109

1A.

R110

750

 

R124

1K

TRIMMER

D110

1A.

R111

50K

TRIMMER

R125

4.7K

4W

D111

1A.

R112

27K

 

R126

1K

TRIMMER

D112

1A.

R113

39K

 

R127

150

 

 

D113

1A.

R114

10K

 

R128

1K

 

 

D114

1A.

R115

68K

 

R129

15K

 

 

DZ101

20V.

 

 

 

 

 

 

 

C202

.02MFD

C203

50MFD

C204

.005MFD

C205

50MFD

C206

.005MFD

1CR

3PDT 24V.D.C.

D201

1A.

 

D202

1A.

 

D203

1A.

 

D204

1A.

 

D205

1A.

 

R201

40

12W

R202

100

 

R203

100K

R204

27

 

R205

4.7K

R206

1K

 

F201

1/2A 125V CR 250V

 

SLOW BLOW FUSE

SCR201

4A 400V

TP201

TRANSIENT PROTECTION

VARIABLE VOLTAGE CIRCUIT (BOARD #3)

C301

2MFD

R301

6.8K

 

C302

.10MFD

R302

5.6K

(2%)

C303

.01MFD

R303

1K (2%)

C304

.047MFD

R304

3.9K

(2%)

C305

.01MFD

R305

3.3K

 

C306, C307

.02MFD

R306

4.7K

2W

D301

1A.

R307

100

 

D302

2A.

R308

5K

TRIMMER

D303

3A.

R309

15

 

D304

4A.

R310

47

 

DZ301

62V

R311

68

 

DZ302

10V

S304

POWER SOURCE

Q301

2N3393

 

SELECTOR SWITCH

Q302

2N4125

QU301

UJT

 

PT301

1:1:1 PULSE TRANSFORMER

TP301

TRANSIENT PROTECTION

 

ELECTRICAL SYMBOLS

LEAD COLOR CODING

PER E1537

 

B - BLACK

R - RED

 

 

U - BLUE

W - WHITE

COMPONENTS NOT ON P.C. BOARD

R4

2

50W

R9

5K

 

2W POT.

R20

10K

2W POT.

T1

110-24V TRANSFORMER

2CR

REED SWITCH (ACTUATED BY WELDING CURRENT)

4CR

GROUNDING LEAD PROTECTOR

S1

SPST GUN SWITCH

S2

SPDT INTERLOCK SWITCH

S3

SPDT DIRECTION SWITCH

FOR CONTROL P.C. BOARDS L5767-1 AND HIGHER, USE M16802 SCHEMATIC FOR COMPONENT VALUES AND CIRCUIT CONNECTIONS

FOR VARIABLE VOLTAGE P.C. BOARD L5039-1 OR HIGHER, USE M16441 SCHEMATIC FOR COMPONENT VALUES AND CIRCUIT CONNECTIONS

SINCE COMPONENTS OR CIRCUITRY ON A PRINTED CIRCUIT BOARD MAY CHANGE WITHOUT AFFECTING THE INTER- CHANGEABILITY OF A COMPLETE BOARD, THIS DIAGRAM MAY NOT SHOW THE EXACT COMPONENTS OR CIRCUITRY OF CONTROLS HAVING A COMMON CODE NUMBER.

12-3-92E

M14680

NOTE: Lincoln Electric assumes no responsibility for liablilities resulting from board level troubleshooting. PC Board repairs will invalidate your factory warranty. Individual Printed Circuit Board Components are not available from Lincoln Electric. This information is provided for reference only. Lincoln Electric discourages board level troubleshooting and repair since it may compromise the quality of the design and may result in danger to the Machine Operator or Technician. Improper PC board repairs could result in damage to the machine.

LN-8

Image 94
Contents LN-8 Semiautomatic Wire Feeder Safety LN-8Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Installation LN-8 with K377 Electrode DiameterLN-8 with K303 LN-8 with K378Table A.1 Work Lead Specifications Power Source ConnectionsLN-8N and LN-8NE Power Source Selection Switch Variable Voltage PC Board LN-8S and LN-8SE and Converted LN-8N and LN-8NEPower Source Connection Diagrams Table A.2 LN-8 Power Source Connection DiagramsSection TOC Installation TOC 9A-9 Figure A.5 Connection of LN-8 to R3S-250 and R3S-32510A-10 Figure A.6 Connection of LN-8 to DC-600Power Source To LN-8 Input Cable Plug Control Cable LN-8 for Same Polarity Operation LN-8 for Opposite Polarity Operation Shock Can KillFigure A.10 for Power Sources Other than Lincoln Electric 14A-14LN-8N and LN-8S Cable Clamp Conductor Electrode Wire Reel BasecontrolInput Cable Connections LN-8NE and LN-8SELocking Connections to Wire FeederExtension Tube Connector ScrewFigure A.14 Wire Feeder Handle Installation SELF-TAPPING Screw Hinge HandleLN-8S and LN-8SE Continuous Flux Feed Submerged ARC Handling ProceduresGUN and Cable Assemblies GeneralOperation Constant Current Controls Safety InstructionsControls and Their Functions Gouging SparksConstant Voltage Controls Current Controls VoltageCircuit Protection Avoiding Ground Lead Protector GLP ActivationWire Feed Rolls and Guide Tubes Figure B.3 Wire Feed Rolls and Guide Tube InstallationSetting for CV or CC Power Sources Voltage Power Source Welding with a ConstantMounting a 50 or 60 lb Coil Slots Coil ReelK363-P READI-REEL Adapter Wire Reel Loading K1524-1 Universal Wire Reel StandAdapter Innershield Coils To Mount 10 to 44 lb 4.5 to 20 kg Spools12 in./300 mm Diameter or 14 lb 6 kg READI-REELS a K438 READI-REEL Adapter Must be UsedFeeding Electrode to the LN-8NE or LN-8SE with Extension Feeding Electrode to the LN-8N or LN-8SBrass Blocks Hand Crank ARM Flux Tank Loading Slow Acceleration Starting Code 7926 and AboveAccessories Table C.1 LN-8 Wire Feeder Accessories GeneralK178 Mounting Platform K161 Mechanized Travel Power PackK163 Undercarriage Requires K303, K377, or K378 K58 Magnetic SeparatorReel Mounting Accessories Welding Guns Welding GUN Accessories Constant Current Conversion PartsLN-8 Maintenance Table of Contents Maintenance SectionRoutine Maintenance Periodic Maintenance Table of Contents Theory of Operation Section Theory of OperationPower Input Circuits General DescriptionGUN Trigger and 1CR Relay Contact Control Circuits Figure E.2 GUN Trigger and 1CR Contact Control CircuitsFuse Field 5E-5 SCR OperationApplied Later CYCLE, the SCR Output Is Decreased LN-8 Troubleshooting and Repair HOW to USE Troubleshooting Guide Return to Return to Section TOCTroubleshooting & Repair PC Board Troubleshooting ProceduresTroubleshooting Guide Problems SymptomsFunction Problems Transformer Test Perform the 1CR Relay Test Feeding Problems Welding Problems LN-8 Electrical Sequence of Operation Figure F.1 LN-8 Electrical Sequence of Operation Trigger Transformer Test Test DescriptionTrigger Transformer Test Internal Voltage Test Circuit Applied Breaker ConnectorReceptacle Control BoardInternal Voltage Test Table F.1 Voltage Test Points1CR Relay Test 1CR Relay Test 1CR Relay Test Table F.2 Relay Test Terminal ConnectionsDrive Motor Test Drive Motor Test Figure F.6 GUN Terminal Jumper Locations 1CRTo further check the drive motor Table F.3 Drive Motor Test PointsPotentiometer Replacement Repair Procedure Circuit Breaker Replacement Ground Lead Protector Switch Mount Flatwasher Lockwasher NUT Retaining NUTGround Lead Protector Push Button Switch Replacement Ground Lead Protector Push Button Trigger Transformer Replacement Relay PC Board Roundhead Screw Insulation Sheet Trigger Transformer NUTPC Board Replacement Figure F.10 PC Board Locations Control PC Board Variable Voltage PC Board Relay PC BoardRelay Board Removal Control PC Board Replacement Wire Drive Assembly and Component Replacement Green Ground Yellow BlackWhite Blue TWOShunt #568 #567Motor Gearbox Insulation Sheet Mounting PlateTOC Retest After Repair Electrical Diagrams LN-8N, -8NE, -8S, and -8SE Wiring Diagram Connection Schematic Source Power to WorkOperating Schematic 1CR Wire Feed Motor FieldControl Board L5767 Schematic Variable Voltage Board L5039 Schematic Control Board L5767 Layout ControlVariable Voltage Board L5039 Layout SVM Error Reporting Form