Lincoln Electric SVM132-A Connections to Wire Feeder, Locking, Screw, Control, Cable, Extension

Page 22

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-16

 

INSTALLATION

A-16

 

 

 

 

FIGURE A.12 – INPUT CONTROL CABLE AND ELECTRODE CABLE EXTENSIONS

 

WIRE￿

 

 

 

 

DRIVE￿

 

POLARIZED￿

CONTROL￿

 

UNIT

 

 

CONTROL￿

PLUGS

 

CABLE

 

 

CABLE￿

EXTENSION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRODE￿

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRODE￿

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EXTENSION￿

BRASS￿

 

 

 

 

 

 

WIRE￿

 

 

 

 

 

 

 

 

 

 

 

 

 

CABLE

HAND￿

 

REEL￿

 

 

 

 

 

 

 

BLOCK

CRANK

 

BASE

 

 

 

 

 

 

 

 

 

 

 

2. The standard cable setup consists of an electrode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

cable and a control cable with a polarized plug on

 

 

 

FIGURE A.13 – CABLE EXTENSION

the wire feeder end. Position the control cable

 

 

 

CONNECTIONS TO WIRE FEEDER

with the polarized plug at the wire reel base. Refer

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

to Figure A.12.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Connect the electrode cable to the brass block on the hand crank assembly using the screw provided.

4.

Position the 22-1/2 or 45 ft (6.9 or 13.7 m) control

 

LOCKING￿

 

cable extension so the polarized connector with

 

 

 

SCREW

 

the threads on its O.D. is at the wire reel base.

 

 

 

 

5.

Connect the polarized connectors of the control

 

CONTROL￿

 

cable together.

 

CABLE￿

6.

Place both the control and electrode cables under

 

EXTENSION

 

 

 

the clamp on the wire reel base and tighten the

 

 

 

screws.

 

 

7.

Insert the connector on the electrode cable

 

 

 

extension into the brass block of the hand crank

REAR￿

 

 

assembly and tighten with a 3/16 in. Allen wrench.

 

 

BRASS￿

 

 

 

 

8.

At the wire feeder, connect the polarized plug of

BLOCK

 

ELECTRODE￿

INGOING￿

 

the control cable extension into the mating

 

receptacle on the back of the wire feeder. Refer to

CABLE￿

GUIDE￿

 

Figure A.13.

EXTENSION￿

TUBE

 

 

CONNECTOR

 

LN-8

Image 22
Contents LN-8 Semiautomatic Wire Feeder Safety LN-8Electric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcMaster Table of Contents for ALL Sections Installation LN-8 with K377 Electrode DiameterLN-8 with K303 LN-8 with K378Table A.1 Work Lead Specifications Power Source ConnectionsLN-8N and LN-8NE Power Source Selection Switch Variable Voltage PC Board LN-8S and LN-8SE and Converted LN-8N and LN-8NEPower Source Connection Diagrams Table A.2 LN-8 Power Source Connection DiagramsSection TOC Installation TOC 9A-9 Figure A.5 Connection of LN-8 to R3S-250 and R3S-32510A-10 Figure A.6 Connection of LN-8 to DC-600Power Source To LN-8 Input Cable Plug Control Cable LN-8 for Same Polarity Operation LN-8 for Opposite Polarity Operation Shock Can KillFigure A.10 for Power Sources Other than Lincoln Electric 14A-14LN-8N and LN-8S Cable Clamp Conductor Electrode Wire Reel BasecontrolInput Cable Connections LN-8NE and LN-8SELocking Connections to Wire FeederExtension Tube Connector ScrewFigure A.14 Wire Feeder Handle Installation SELF-TAPPING Screw Hinge HandleLN-8S and LN-8SE Continuous Flux Feed Submerged ARC Handling ProceduresGUN and Cable Assemblies GeneralOperation Constant Current Controls Safety InstructionsControls and Their Functions Gouging SparksConstant Voltage Controls Current Controls VoltageCircuit Protection Avoiding Ground Lead Protector GLP ActivationWire Feed Rolls and Guide Tubes Figure B.3 Wire Feed Rolls and Guide Tube InstallationSetting for CV or CC Power Sources Voltage Power Source Welding with a ConstantMounting a 50 or 60 lb Coil Slots Coil ReelK363-P READI-REEL Adapter Wire Reel Loading K1524-1 Universal Wire Reel StandAdapter Innershield Coils To Mount 10 to 44 lb 4.5 to 20 kg Spools12 in./300 mm Diameter or 14 lb 6 kg READI-REELS a K438 READI-REEL Adapter Must be UsedFeeding Electrode to the LN-8NE or LN-8SE with Extension Feeding Electrode to the LN-8N or LN-8SBrass Blocks Hand Crank ARM Flux Tank Loading Slow Acceleration Starting Code 7926 and AboveAccessories Table C.1 LN-8 Wire Feeder Accessories GeneralK178 Mounting Platform K161 Mechanized Travel Power PackK163 Undercarriage Requires K303, K377, or K378 K58 Magnetic SeparatorReel Mounting Accessories Welding Guns Welding GUN Accessories Constant Current Conversion PartsLN-8 Maintenance Table of Contents Maintenance SectionRoutine Maintenance Periodic Maintenance Table of Contents Theory of Operation Section Theory of OperationPower Input Circuits General DescriptionGUN Trigger and 1CR Relay Contact Control Circuits Figure E.2 GUN Trigger and 1CR Contact Control CircuitsFuse Field 5E-5 SCR OperationApplied Later CYCLE, the SCR Output Is Decreased LN-8 Troubleshooting and Repair HOW to USE Troubleshooting Guide Return to Return to Section TOCTroubleshooting & Repair PC Board Troubleshooting ProceduresTroubleshooting Guide Problems SymptomsFunction Problems Transformer Test Perform the 1CR Relay Test Feeding Problems Welding Problems LN-8 Electrical Sequence of Operation Figure F.1 LN-8 Electrical Sequence of Operation Trigger Transformer Test Test DescriptionTrigger Transformer Test Internal Voltage Test Circuit Applied Breaker ConnectorReceptacle Control BoardInternal Voltage Test Table F.1 Voltage Test Points1CR Relay Test 1CR Relay Test 1CR Relay Test Table F.2 Relay Test Terminal ConnectionsDrive Motor Test Drive Motor Test Figure F.6 GUN Terminal Jumper Locations 1CRTo further check the drive motor Table F.3 Drive Motor Test PointsPotentiometer Replacement Repair Procedure Circuit Breaker Replacement Ground Lead Protector Switch Mount Flatwasher Lockwasher NUT Retaining NUTGround Lead Protector Push Button Switch Replacement Ground Lead Protector Push Button Trigger Transformer Replacement Relay PC Board Roundhead Screw Insulation Sheet Trigger Transformer NUTPC Board Replacement Figure F.10 PC Board Locations Control PC Board Variable Voltage PC Board Relay PC BoardRelay Board Removal Control PC Board Replacement Wire Drive Assembly and Component Replacement Green Ground Yellow BlackWhite Blue TWOShunt #568 #567Motor Gearbox Insulation Sheet Mounting PlateTOC Retest After Repair Electrical Diagrams LN-8N, -8NE, -8S, and -8SE Wiring Diagram Connection Schematic Source Power to WorkOperating Schematic 1CR Wire Feed Motor FieldControl Board L5767 Schematic Variable Voltage Board L5039 Schematic Control Board L5767 Layout ControlVariable Voltage Board L5039 Layout SVM Error Reporting Form