Lincoln Electric S22693-121 manual Contact TIP Alignment

Page 15

C-2

MAINTENANCE

C-2

 

 

 

CONTACT TIP ALIGNMENT

During gooseneck replacement or after a torch colli- sion it may be required to check the contact tip align- ment. If using a robot, it is recommended that a tool center pointer is placed in the robotic cell to define the location of the lead wire. A second locating station should be installed that provides two locating pins that will check the alignment of the lead and trail wire.

If the torch requires maintenance that will effect the alignment of the lead or trail wire placement, the torch should be removed from the robot or hard automation work cell and the L10430-1 torch alignment tool should be used to realign wire placement.

L10430-1 Torch Alignment Tool

Alignment Procedure

1.Remove torch from automated equipment.

2.Remove torch nozzle assembly.

3.Select desired contact tip spacing by pivoting front alignment block of alignment fixture to correct spacing. (Two wire spacings are provided 5/16" standard and a 3/8" wide.)

4.With retainer, diffusers and contact tips in place insert a straight portion of welding wire into each contact tip to simulate a 5/8" wire extension past the contact tip.

5.Secure mounting bracket assembly of torch to back mounting block of alignment fixture by securing torch mounting arm to the keyed .750" mounting dowel provided.

6.Loosen the 5 hex head screws of mounting bracket that hold goosenecks in place.

7.Pivot goosenecks to align the two 5/8" extended wires to the indictor marks on the front block of alignment gauge.

8.Secure goosenecks in place by tightening the five hex head screws.

9.Recheck wire alignment.

10.Remove torch from alignment fixture.

800 AMP TANDEM MIG TORCH

Image 15
Contents Tandem MIG 800 Amperage Welding Torch February California Proposition 65 Warnings SafetyElectric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Tandem MIG Torch Cable Length Availability InstallationLiner Installation General DescriptionTorch Mounting Contact TIP and Diffuser Installation Torch Connection to Wire FeederContact TIP Selection Contact TIP Size Wire StraightenersOperation ANTI-SPATTER Spray Nozzle Reaming StationsGooseneck Replacement MaintenanceContact TIP Replacement Liner ReplacementContact TIP Alignment L10430-1 Torch Alignment Tool Alignment ProcedureS22693-XXX MIG 800 amp Torch Maintenance Maintenance HOW to USE Troubleshooting Guide TroubleshootingDrive rolls turn, but wire will AMP Tandem MIG Torch AMP Tandem MIG Torch Precaucion Warnung