OPERATION |
●No external shielding gas is required when used with Lincoln Innershield .035” (0,9 mm)
●Spindle accommodates both 8 in. (200 mm) diame- ter and 4 in. (100 mm) diameter spools of wire.
WELDING CAPABILITY
The
LIMITATIONS
Arc Gouging cannot be performed with the
CONTROLS AND SETTINGS
Refer to Figure B.1b.
4.Circuit Breaker – Protects machine from damage if maximum output is exceeded. Button will extend out when tripped (Manual reset).Refer to Figure B.1b
5.Gun Trigger - Activates welding output, wire feed, and gas solenoid operation. Releasing the trigger deactivates welding and simultaneously activates the “burnback” function so that the welding wire does not stick in the weld puddle.
Refer to Figure B.1a.
1.Power ON/OFF Switch — When the power is on the fan motor will run and air will be exhausted out the louvers in the front of the machine. The welding output and wire feeder remain off until the gun trigger is pressed.
2.Voltage Control — A
3.Wire Speed Control — Controls the wire feed speed from 50 – 400 in/min (1.2 – 10.2 m/min). The control can be preset on the dial to the setting specified on the SP- 175T Application Chart located on the inside of the wire feed section door.
ON
OFF
ARC VOLTS
WIRE SPEED