Lincoln Electric ES 275I INPuT Voltage Reconnect PROCEDuRE, OuTPuT Connections, OuTPuT CAbLES

Page 10

A-3

INSTALLATION

A-3

 

 

 

INPuT VOLTAGE RECONNECT PROCEDuRE

When received directly from the factory, units are con- nected for, 460 VAC. If 460 VAC is the desired input, then the machine may be connected to the power sys- tem without any setup required inside the reconnect door. For other voltages refer to the instructions locat- ed on the Reconnect Panel Access Door or follow the instructions below.

CAuTION

Failure to follow these instructions can cause immediate failure of components within the welder.

------------------------------------------------------------------------

1.Open the access door on the left side of the machine.

2.For 208-230: Position the large switch to 208-230.

For 380-575: Position the large switch to 380-575.

3.Move the “A” lead to the appropriate terminal. Refer to figure A.1 below.

OuTPuT CONNECTIONS

Refer to figure B.1 for the location of the 3-Pin Remote Receptacle and the Output Terminals.

OuTPuT CAbLES

Select the output cable size based on Table A.1.

TAbLE A.1

Cable Sizes for Combined Length of Electrode and

Work Cable ( Copper Cable Rated at 75°C).

Length

Cable Size

up to 150 ft.(46m)

1/0 (50mm2)

up to 250 ft.(72m)

2/0 (70mm2)

 

 

RECONNECT PROCEDURE

. Disconnect input power before

1. BE SURE POWER SWITCH IS OFF.

.

inspecting or servicing machine.

2. CONNECT LEAD 'A' TO DESIRED

Do not operate with wraparound

INPUT VOLTAGE RANGE.

 

.

removed.

 

 

Do not touch electrically live parts.

575V

 

.

Only qualified persons should install,

440-460V

 

 

use or service this equipment.

 

 

380-415V

'A'

IF MACHINE CEASES TO OPERATE (NO METER, NO FAN)

220-230V

 

AND THERE IS NO OTHER KNOWN FAILURE: CHECK FUSE;

208V

 

REPLACE WITH SPECIFIED FUSE.

 

 

 

3. POSITION SWITCH TO DESIRED INPUT VOLTAGE RANGE.

VOLTAGE=380-575V

VOLTAGE=208-230V

Figure A.1 Input Voltage Reconnect Instructions

ES 275i

Image 10
Contents RED-D-ARC Safety Electric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiIvSAFETY PRÉCAuTIONS DE SûretéThank You TAbLE of Contents Technical Specifications ES ThREE PhASE Single PhASEHIGh FREQuENCY Protection Safety PRECAuTIONSSelect SuITAbLE Location INPuT ConnectionsOuTPuT Connections INPuT Voltage Reconnect PROCEDuREOuTPuT CAbLES Welding CAPAbILITY Operational FEATuRESLimitations Mode SWITCh LOCAL/REMOTE SWITCh PlaceFull range is from -10Soft to +10Crisp Stick Welding Constant CuRRENT ProcessesPIN Remote Receptacle TIG WeldingPOWER-uP SEQuENCE ThERMAL ProtectionINPuT Filter Capacitor DISChARGE PROCEDuRE FIGuRE D.1 Location of INPuT Filter Capacitor TerminalsROuTINE MAINTENANCE FIGuRE D.2 Location of Maintenance Components TROubLEShOOTING HOW to uSE TROubLEShOOTING GuIDEPC bOARD TROubLEShOOTING PROCEDuRES Board can be dam- aged by static electricityCAuSE COuRSE of Action PRObLEMS POSSIbLESymptoms Input Voltage ReconnectVoltage Reconnect Procedure See Installation Section of this See Input Voltage Reconnect Procedure FacilityWelding PRObLEMS Wiring Diagram RED-D-ARC ES275i Wiring DIAGRAM- CodeG4365-4 Electrical Dimension Print L11981Page Precaucion Warnung