INPuT VOLTAGE RECONNECT PROCEDuRE
When received directly from the factory, units are con- nected for, 460 VAC. If 460 VAC is the desired input, then the machine may be connected to the power sys- tem without any setup required inside the reconnect door. For other voltages refer to the instructions locat- ed on the Reconnect Panel Access Door or follow the instructions below.
CAuTION
Failure to follow these instructions can cause immediate failure of components within the welder.
1.Open the access door on the left side of the machine.
2.For
For
3.Move the “A” lead to the appropriate terminal. Refer to figure A.1 below.
OuTPuT CONNECTIONS
Refer to figure B.1 for the location of the
OuTPuT CAbLES
Select the output cable size based on Table A.1.
TAbLE A.1
Cable Sizes for Combined Length of Electrode and
Work Cable ( Copper Cable Rated at 75°C).
Length | Cable Size |
up to 150 ft.(46m) | 1/0 (50mm2) |
up to 250 ft.(72m) | 2/0 (70mm2) |
|
|
RECONNECT PROCEDURE | . Disconnect input power before | |||
1. BE SURE POWER SWITCH IS OFF. | ||||
. | inspecting or servicing machine. | |||
2. CONNECT LEAD 'A' TO DESIRED | Do not operate with wraparound | |||
INPUT VOLTAGE RANGE. |
| . | removed. | |
|
| Do not touch electrically live parts. | ||
575V |
| . | Only qualified persons should install, | |
| ||||
| use or service this equipment. | |||
|
| |||
'A' | IF MACHINE CEASES TO OPERATE (NO METER, NO FAN) | |||
| AND THERE IS NO OTHER KNOWN FAILURE: CHECK FUSE; | |||
208V |
| REPLACE WITH SPECIFIED FUSE. | ||
|
|
|
3. POSITION SWITCH TO DESIRED INPUT VOLTAGE RANGE.
Figure A.1 Input Voltage Reconnect Instructions
ES 275i