Lincoln Electric ES 275I specifications Operational FEATuRES, Welding CAPAbILITY, Limitations

Page 11

b-1

OPERATION

b-1

 

 

 

Read and understand this entire section before operating your machine.

SAFETY PRECAuTIONS

WARNING

ELECTRIC ShOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

Insulate yourself from the work and ground.

Always wear dry insulating gloves.

____________________________________

FuMES AND GASES can be dangerous.

• Keep your head out of fumes.

Use ventilation or exhaust to remove fumes from breathing zone.

____________________________________

WELDING, CuTTING and GOuGING SPARKS

can cause fire or explosion

Keep flammable material away.

Do not weld, cut or gouge on contain- ers that have held combustibles.

____________________________________

ARC RAYS can burn.

Wear eye, ear and body protection.

GENERAL DESCRIPTION

The ES 275i is a 275 amp arc welding power source that utilizes single or three phase input power, to pro- duce constant current output. The welding response of this Invertec has been optimized for stick (SMAW) and TIG (GTAW).

OPERATIONAL FEATuRES

The ES 275i provides continuous total range output current adjustment, selectable welding modes and local or remote output control. Welding characteristics can be controlled via an arc force control. Additionally, starting characteristics can be adjusted via a “hot start” control.

WELDING CAPAbILITY

The ES 275i is rated at 275 amps, 35% duty cycle (based on a 10 minute cycle). It is also rated at 200 amps, 100% duty cycle, and 250 amps, 60% duty cycle.

LIMITATIONS

The ES 275i is not recommended for pipe thawing.

____________________________________

Only qualified personnel should operate this equip- ment. Observe all safety information throughout this manual.

ES 275i

Image 11
Contents RED-D-ARC Safety Electric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionPRÉCAuTIONS DE Sûreté IvSAFETYThank You TAbLE of Contents ThREE PhASE Single PhASE Technical Specifications ESINPuT Connections Safety PRECAuTIONSSelect SuITAbLE Location HIGh FREQuENCY ProtectionOuTPuT CAbLES INPuT Voltage Reconnect PROCEDuREOuTPuT Connections Limitations Operational FEATuRESWelding CAPAbILITY Full range is from -10Soft to +10Crisp LOCAL/REMOTE SWITCh PlaceMode SWITCh TIG Welding Constant CuRRENT ProcessesPIN Remote Receptacle Stick WeldingThERMAL Protection POWER-uP SEQuENCEFIGuRE D.1 Location of INPuT Filter Capacitor Terminals INPuT Filter Capacitor DISChARGE PROCEDuREROuTINE MAINTENANCE FIGuRE D.2 Location of Maintenance Components HOW to uSE TROubLEShOOTING GuIDE TROubLEShOOTINGBoard can be dam- aged by static electricity PC bOARD TROubLEShOOTING PROCEDuRESInput Voltage Reconnect PRObLEMS POSSIbLESymptoms CAuSE COuRSE of ActionVoltage Reconnect Procedure See Installation Section of this Facility See Input Voltage Reconnect ProcedureWelding PRObLEMS Wiring DIAGRAM- Code Wiring Diagram RED-D-ARC ES275iG4365-4 Electrical L11981 Dimension PrintPage Precaucion Warnung