Lincoln Electric CV-250 manual Accessories, Factory Installed OPTIONS/ACCESSORIES

Page 18

C-1

ACCESSORIES

C-1

 

 

 

FACTORY INSTALLED

OPTIONS/ACCESSORIES

There are no factory installed options/accessories on the CV-250.

FIELD INSTALLED OPTIONS

REMOTE VOLTAGE CONTROL (K857)

The K857 consists of a control box with 25 feet (7.6

m)of four conductor cable. Installation of a K857 Remote Voltage Control in the CV-250 requires a K864 Remote Control Adapter. Refer to the instruc- tions provided with the K857 for hookup to the CV- 250. When properly connected, and with the CV-250 Local-Remote Switch in the "Remote" position, the K857 functions the same as the CV-250 Voltage Adjust control, enabling minimum to maximum output voltage adjustment of the CV-250.

UNDERCARRIAGE (K835)

Includes front casters, a handle, a bracket, and a rear wheeled platform that is capable of carrying one gas cylinder. The CV-250 lifting eye is not functional with the K835 undercarriage installed.

TWO-CYLINDER UNDERCARRIAGE (K874)

Platform type undercarriage that can accommodate either one or two gas bottles, or one gas bottle and a Magnum water cooler. The CV-250 lifting eye is not functional when the K874 undercarriage is installed.

WIRE FEEDER SWIVEL MOUNT (K178-1)

Allows an LN-7 or LN-742 to be securely mounted on the roof of a CV-250.

UNIVERSAL ADAPTER (K867)

Provides a means of connecting auxiliary equipment to the wire feeder receptacle on the CV-250 power source. Consists of a 14-pin MS-type (Amphenol) plug with 8 inch (0.2 meter) long flex leads, one for each circuit present in the wire feeder receptacle. Not required when using a standard wire feeder input cable, such as a K480, with a Lincoln wire feeder.

COMPATIBLE LINCOLN EQUIPMENT

The CV-250 is intended for use with the LN-7, LN-742, and LN-25 wire feed units. Use the Cables / Kits listed below to make connection easily:

LN-7 / LN-7GMA

Requires K480 Input Cable

 

 

 

LN-25

Requires K484

Jumper Plug Kit

 

 

 

LN-25 w/K444-1

Requires K864

Remote Control

Remote Voltage

Adapter and K484 Jumper Plug

Control Kit

Kit

 

 

 

 

LN-742 / LN-742H

Requires K591

Input Cable

 

 

 

CV-250

Image 18
Contents Safety Depends on You IdealarcSafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Idealarc CV-250Input Connections Safety PrecautionsSelect Suitable Location StackingField Installed Options Output ConnectionsParalleling Operation Operating InstructionsGeneral Warnings Power Source Operation Operational Features and ControlsDesign Features General DescriptionControls and Settings Thermal Protection Indication LightIndicates Warning Information Located on Right Case Side Voltage ControlC. Output Connectors Output Panel ConnectionsAuxiliary Power Starting the MachineOverload Protection Accessories Factory Installed OPTIONS/ACCESSORIESCompatible Lincoln Equipment Safety Precautions MaintenanceGeneral Maintenance Machine and Circuit Protection1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideTroubleshooting BUILT-IN Diagnostic Routines and Error CodesError Code Trouble Remedy Machine Troubleshooting Guide ProblemsPossible Areas Recommended Symptoms Poor arc striking with semiautomatic Poor work connection Options Troubleshooting Guide Control PC Board Meter PC BoardOutput Voltage Fault Protection OperationOptional K857 Remote Control Check Checking Snubber CircuitWiring Diagram CV 250 60Hz Diagrams CV Power Source to AN LN-7 and K857Source to a K867 AdapterPower Source to a K867 / K775 / LN CV Power Source to AN LN-25 250CV Power Source to AN LN-25 / K444-1 Lincoln Power Source PIN Amphenol Installation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire Feeders Dimension Print How To Read Shop Drawings $700.00Precaucion Warnung