Lincoln Electric CV-250 manual Controls and Settings, Thermal Protection Indication Light

Page 14

B-3

OPERATION

B-3

 

 

 

CONTROLS AND SETTINGS

All operator controls and adjustments are located on the case front of the CV-250. Refer to Figures B.1, and B.2 and corresponding explanations.

FIGURE B.1 - CONTROL PANEL

LOCAL

REMOTE

+

-

 

 

H

J

A. POWER SWITCH

F.

42 VOLT CIRCUIT BREAKER

B. VOLTAGE ADJUSTMENT

G.

115 VOLT CIRCUIT BREAKER

C. THERMAL PROTECTION INDICATION LIGHT

H.

LOCAL / REMOTE SWITCH

D. VOLTS / AMPS SWITCH

J.

WIRE FEEDER VOLTMETER SWITCH

E. DIGITAL VOLTMETER / AMMETER

 

 

 

A.POWER SWITCH

-A two-position toggle switch.Controls the input power to the CV-250.

B.VOLTAGE ADJUST

-Controls the CV-250 output voltage.

C.THERMAL PROTECTION INDICATION LIGHT

-Indicates that the protection thermostat has activated. The digital meter will display "E10" when this occurs. When the light turns off, the machine will be capable of supplying welding output power again.

NOTE: Leaving the power switch in the "ON" posi- tion will result in the most rapid cooling.

D.VOLTS/AMPS SWITCH

-Selects either output current or arc voltage to be displayed on the digital meter.

E.DIGITAL VOLTMETER/AMMETER

-Displays the CV-250 output current, or the arc voltage.

NOTE: Due to voltage drops in the welding cables and at cable connection points, the actual arc voltage may be lower than that displayed on the voltmeter. Use welding cables of the proper capacity and make sure all connec- tions are tight to minimize this effect.

F. 42 VOLT CIRCUIT BREAKER

-Protects the 42 volt 41-42 circuit in the wire feeder receptacle from overloads and shorts. If this circuit breaker opens, the CV-250 will work normally. However, any equipment powered by the 42 volt circuit will not work.

G. 115 VOLT CIRCUIT BREAKER

-Protects the 115 volt 31-32 circuit in the wire feeder receptacle from overloads and shorts. If this circuit breaker opens, the CV-250 will work normally. However, any equipment powered by the 115 volt circuit will not work.

H. LOCAL/REMOTE SWITCH

-Determines whether the welding voltage is controlled at the CV-250, or controlled remotely by a remote output control (such as a K857).

CV-250

Image 14
Contents Safety Depends on You IdealarcSafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Idealarc CV-250Input Connections Safety PrecautionsSelect Suitable Location StackingField Installed Options Output ConnectionsParalleling General Warnings OperationOperating Instructions Power Source Operation Operational Features and ControlsDesign Features General DescriptionControls and Settings Thermal Protection Indication LightIndicates Warning Information Located on Right Case Side Voltage ControlC. Output Connectors Output Panel ConnectionsOverload Protection Auxiliary PowerStarting the Machine Compatible Lincoln Equipment AccessoriesFactory Installed OPTIONS/ACCESSORIES Safety Precautions MaintenanceGeneral Maintenance Machine and Circuit Protection1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideError Code Trouble Remedy TroubleshootingBUILT-IN Diagnostic Routines and Error Codes Machine Troubleshooting Guide ProblemsPossible Areas Recommended Symptoms Poor arc striking with semiautomatic Poor work connection Options Troubleshooting Guide Control PC Board Meter PC BoardOutput Voltage Fault Protection OperationOptional K857 Remote Control Check Checking Snubber CircuitWiring Diagram CV 250 60Hz Diagrams CV Power Source to AN LN-7 and K857Source to a K867 AdapterPower Source to a K867 / K775 / LN CV Power Source to AN LN-25 250CV Power Source to AN LN-25 / K444-1 Lincoln Power Source PIN Amphenol Installation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire Feeders Dimension Print How To Read Shop Drawings $700.00Precaucion Warnung