E-7

TROUBLESHOOTING

E-7

 

 

 

Procedure for Replacing PC Boards

WARNING

ELECTRIC SHOCK can kill.

Have a qualified individual install and service this equipment.

Turn the power source input power off at the disconnect switch before work- ing on this equipment.

Do not touch electrically hot parts.

---------------------------------------------------------------------

Before replacing a PC board which is suspected of being defective, visually inspect the PC board in ques- tion for any electrical or mechanical damage to any of its components and conductors on the back of the board.

a. If there is no visible damage to the PC board, install a new one and see if this remedies the prob- lem. If the problem is remedied, reinstall the old PC board to see if the problem still exists. If it does no longer exist with old PC board:

1.Check the PC board harness connector pins for corrosion, contamination, or looseness.

2.Check leads in the plug harness for loose or intermittent connection.

b.If PC board is visibly damaged electrically, before possibly subjecting the new PC board to the same cause of failure, check for possible shorts, opens, or grounds caused by:

1.Frayed or pinched lead insulation.

2.Poor lead termination, such as a poor contact or a short to adjacent connection or surface.

3.Shorted or open motor leads, or other external leads.

4.Foreign matter or interference behind the PC boards.

c.If PC board is visibly damaged mechanically, inspect for cause, then remedy before installing a replacement PC board.

If there is damage to the PC board or if replacing PC board corrects problem, return it to the local Lincoln Electric Field Service Shop.

PC BOARD TROUBLESHOOTING PROCEDURES

CONTROL PC BOARD

The Control PC Board controls all machine functions including the thermal protection indicator light and the Meter PC Board. Most problems, if not caused by faulty wiring machine misuse, will stem from a faulty Control PC Board.

Perform the following diagnostic procedure before replacing the Control PC Board.

1.Turn off the input power at the fuse box.

2.Check for loose connections in the PC Board plugs, particularly J3.

3.Disconnect the J3 plug from the Control PC Board. Measure the resistance between the following wire terminals in the plug:

A)Between wire #200 and wire #201.

B)Between wire #202 and wire #203.

Both of these resistances should be less than 1 ohm.

If these resistances are not less than 1 ohm, check the wiring back to the main transformer.

If these voltages are less than 1 ohm, refer to "Procedure for Replacing PC Boards."

METER PC BOARD

When the Meter PC Board malfunctions, first determine if the rest of the machine functions correctly. If so, then the problem is in either the harness between the meter and control boards, or in the meter board itself. Refer to "Procedure for Replacing PC Boards". As a last resort, the Control PC Board may have to be replaced.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

CV-250

Image 26
Contents Safety Depends on You IdealarcSafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications Idealarc CV-250Input Connections Safety PrecautionsSelect Suitable Location StackingField Installed Options Output ConnectionsParalleling General Warnings OperationOperating Instructions Power Source Operation Operational Features and ControlsDesign Features General DescriptionControls and Settings Thermal Protection Indication LightIndicates Warning Information Located on Right Case Side Voltage ControlC. Output Connectors Output Panel ConnectionsOverload Protection Auxiliary PowerStarting the Machine Compatible Lincoln Equipment AccessoriesFactory Installed OPTIONS/ACCESSORIES Safety Precautions MaintenanceGeneral Maintenance Machine and Circuit Protection1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideError Code Trouble Remedy TroubleshootingBUILT-IN Diagnostic Routines and Error Codes Machine Troubleshooting Guide ProblemsPossible Areas Recommended Symptoms Poor arc striking with semiautomatic Poor work connection Options Troubleshooting Guide Control PC Board Meter PC BoardOutput Voltage Fault Protection OperationOptional K857 Remote Control Check Checking Snubber CircuitWiring Diagram CV 250 60Hz Diagrams CV Power Source to AN LN-7 and K857Source to a K867 AdapterPower Source to a K867 / K775 / LN CV Power Source to AN LN-25 250CV Power Source to AN LN-25 / K444-1 Lincoln Power Source PIN Amphenol Installation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire Feeders Dimension Print How To Read Shop Drawings $700.00Precaucion Warnung