Lincoln Electric CV-250 manual Installation Instructions

Page 35

CV-250

INSTALLATION INSTRUCTIONS

THIS CONNECTOR IS MEANT TO BE USED WITH LINCOLN POWER SOURCES WHICH HAVE A 14-PIN

WIRE FEEDER RECEPTACLE. IT IS DESIGNED TO ALLOW THE USER TO MAKE CONNECTIONS

TO ANY OF THE 14 CIRCUITS PRESENT IN THE WIRE FEEDER RECEPTACLE.

CONSULT THE WIRING DIAGRAM OF THE POWER SOURCE AND WIRE FEEDER THIS ADAPTER WILL BE USED WITH.

NOT ALL CIRCUITS ARE PRESENT IN EVERY POWER SOURCE, NOR ARE THEY REQUIRED FOR PROPER WIRE FEEDER OPERATION.

1.TURN THE POWER SWITCH OF THE WELDING POWER SOURCE OFF BEFORE INSTALLING THIS ADAPTER TO WIRE FEEDER CABLE.

2.CONSULT THE APPROPRIATE EQUIPMENT WIRING DIAGRAMS FOR THE CONNECTIONS TO UNIVERSAL ADAPTER.

THE STANDARD CONNECTOR PIN DESIGNATIONS AND FUNCTIONS ARE SHOWN BELOW.

 

NOTE:

115V

AC

(31, 32),

42V AC (41, 42), 24V

AC (SPARE) AND

TRIGGER CIRCUIT (2, 4)

 

MAY

OR

MAY NOT BE

ISOLATED, INDEPENDENT

CIRCUITS INSIDE

THE WELDER.

3.USE LUG, CRIMP SPLICE OR SOLDER CONNECTIONS AS REQUIRED AND INSULATE EACH USED AND UNUSED LEAD IN THE UNIVERSAL ADAPTER. THE INSULATING METHOD MUST BE RATED FOR 120V AC OR GREATER.

(SEE

APPROPRIATE WIRING DIAGRAM)

 

 

 

 

 

THESE FUNCTIONS ARE LISTED FOR

 

 

 

 

 

REFERENCE ONLY AND EACH MAY OR

 

K=42

 

 

K=42

MAY

NOT BE

PRESENT IN

YOUR

EQUIPMENT.

A=32

 

J=31

J=31

PIN

LEAD

STANDARD FUNCTION

B=GND

 

 

 

I=41

 

 

 

 

 

 

 

 

 

I=41

A

32

115V AC

 

 

 

 

 

 

 

 

 

 

 

 

 

B

GND

CHASSIS

CONNECTION

L=82

 

 

 

N=SPARE

C

2

TRIGGER

CIRCUIT

 

 

 

H=21

 

 

 

 

 

 

D

4

TRIGGER

 

CIRCUIT

C=2

 

 

N=SPARE

H=21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

E

77

OUTPUT

CONTROL

 

 

 

 

 

F

76

OUTPUT

CONTROL

D=4

 

 

G=75

G=75

 

 

 

 

 

 

 

 

 

 

G

75

OUTPUT

CONTROL

 

 

 

 

 

H

21

WORK

 

 

 

 

E=77

 

F=76

F=76

 

 

 

 

 

 

I

41

42V

AC

 

 

 

 

M=81

 

 

M=81

 

 

 

 

 

 

 

J

31

115V

AC

 

14-PIN BOX

RECEPTACLE,

FRONT

VIEW

14-PIN BOX RECEPTACLE,

 

 

 

 

 

 

 

 

 

 

 

 

 

K

42

42V

AC

 

 

 

 

 

 

 

AND 14-PIN CABLE PLUG,

 

 

 

 

 

 

AND

14-PIN

CABLE PLUG,

REAR

VIEW

L

82

WELDING

MODE

CONTROL

 

 

 

 

 

M

81

WELDING

MODE

CONTROL

 

 

 

 

 

N

SPARE

24V

AC

 

 

 

 

 

 

 

 

A=32

B=GND

C=2

L=82

D=4

E=77

REAR VIEW

FRONT VIEW

3-16-90

S19386

K867 UNIVERSAL ADAPTER INSTALLATION AND CONNECTION INSTRUCTIONS

F-8

DIAGRAMS

F-8

Image 35
Contents Idealarc Safety Depends on YouCalifornia Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Technical Specifications Idealarc CV-250 InstallationStacking Safety PrecautionsSelect Suitable Location Input ConnectionsOutput Connections Field Installed OptionsParalleling General Warnings OperationOperating Instructions General Description Operational Features and ControlsDesign Features Power Source OperationThermal Protection Indication Light Controls and SettingsVoltage Control Indicates Warning Information Located on Right Case SideOutput Panel Connections C. Output ConnectorsOverload Protection Auxiliary PowerStarting the Machine Compatible Lincoln Equipment AccessoriesFactory Installed OPTIONS/ACCESSORIES Machine and Circuit Protection MaintenanceGeneral Maintenance Safety PrecautionsHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Error Code Trouble Remedy TroubleshootingBUILT-IN Diagnostic Routines and Error Codes Problems Machine Troubleshooting GuidePossible Areas Recommended Symptoms Poor arc striking with semiautomatic Poor work connection Options Troubleshooting Guide Meter PC Board Control PC BoardChecking Snubber Circuit Fault Protection OperationOptional K857 Remote Control Check Output VoltageWiring Diagram CV 250 60Hz CV Power Source to AN LN-7 and K857 DiagramsAdapter Source to a K867Power Source to a K867 / K775 / LN 250 CV Power Source to AN LN-25CV Power Source to AN LN-25 / K444-1 Lincoln Power Source PIN Amphenol Installation Instructions TWIST-MATE Cable Plug Installation Instructions Connection of NON-LINCOLN Wire Feeders Dimension Print $700.00 How To Read Shop DrawingsPrecaucion Warnung