OPERATION

B-5

 

 

 

Hold the nozzle standoff 1/8” (3.2mm) to 3/16” (4.7mm) above the workpiece during cutting. Do not let the torch nozzle touch the work or carry a long arc.

Keep moving while cutting. Cut at a steady speed without pausing. Maintain the cutting speed so that the arc leg is 10° to 20° behind the travel direction.

5° - 15° Leading Angle

Direction of Travel

10° - 20° Arc Lag

Use a 5° - 15° leading angle in the direction of the cut.

Use the drag cup to maintain constant standoff for better cut quality and to protect the nozzle from spat- ter.

Use the drag cup with a metal template to prevent nozzle double arcing.

Finish the cut to be made and release the trigger.

When the trigger is released, the arc will stop.

-The gas will continue to flow for 10 seconds of postflow. If the trigger is activated within this time period, the pilot arc will immediately restart.

If the dross is difficult to remove, reduce the cutting speed. High speed dross is more difficult to remove than low speed dross.

The right side of the cut is more square than the left as viewed along the direction of travel.

Tilt the torch about 45° from the workpiece and hold the nozzle 1/8” (3.2mm) to 3/16” (4.7mm) above the workpiece for gouging.

Clean spatter and scale from the nozzle and drag cup frequently.

ANGLE

OF APPROACH

TORCH HELD AT

450 ANGLE

THROUGHOUT GOUGE

ANGLE

MAINTAINED

THROUGHOUT

GOUGE

1.SAFETY LED

If the "SAFETY" LED lights at any time, check the following:

WARNING

ELECTRIC SHOCK CAN KILL.

• Turn off machine at the disconnect switch on the front of the machine before tightening, cleaning or replacing consumables.

----------------------------------------------------------------------------

2.IN NORMAL OPERATION, THE “SAFETY” LED MAY TEMPORARILY ILLUMINATE AND CLEAR ITSELF AUTOMATICALLY WITH- OUT DEPRESSING THE RESET BUTTON.

Check the assembly of the torch consumables. If they are not properly in place, the machine will not start. Make sure that the shield cup is hand tight. Do not use pliers or over tighten.

Check the conditions of the inside of the nozzle. If debris has collected, rub the electrode on the inside bottom of the nozzle to remove any oxide layer that may have built up. Refer to "Suggestions for Extra Utility from the PRO-CUT system".

Check the condition of the electrode. If the end has a crater-like appearance, replace it along with the nozzle. The maximum wear depth of the electrode is approximately .060”. A green and erratic arc will indicate definite electrode failure and the electrode should be replaced immediately.

Replace the nozzle when the orifice exit is eroded away or oval shaped.

If the machine does not reset or continues to trip, consult the Troubleshooting Section.

Use the proper cutting or gouging procedures referred to in Procedure Recommendations.

PRO-CUT 55

Image 18
Contents PRO-CUTTM55 Safety Electric Shock can killPlasma ARC can injure Page Précautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Vii Installation Technical Specifications PRO-CUTThree Phase Single Phase Safety Precautions Select Proper LocationHigh Frequency Interference Protection Single Phase Input Connection for 208/230/460 Volt Machines Input Power Cord Connector InstallationInput Electrical Connections Input Voltage Reconnection Procedure USE on Engine Driven Power SuppliesFrame Grounding GAS Input Connections Output ConnectionsPreheat Temperature for Plasma Cutting OperationDescription User Responsibility Operational Features and ControlsDesign Features Advantages Recommended Processes and EquipmentCutting Capability Consumable LifeControls and Settings LimitationsSafety LED Procedure Recommendations Pilot ARC DiscussionSuggestions for Extra Utility from the PRO-CUT System Accessories General Options AccessoriesMaintenance Input Filter Capacitor Discharge ProcedureRoutine Maintenance Periodic MaintenanceTroubleshooting HOW to USE Troubleshooting GuideElectric Shock can Kill Troubleshooting Field Service Facility Troubleshooting Problems Possible Recommended Symptom Check Consumable Related Safety LED Troubleshooting If the Safety LED is LIT and STEADY, perform the followingWiring Diagram PRO-CUT 55 Codes 10475, 10476, 10571 Diagrams Wiring Diagram Codes 11013 Wiring Diagram Codes 11011, 11012, 11015 Dimension Print PRO-CUT PRO-CUT PRO-CUT Precaucion Warnung