Lincoln Electric IM637-A manual Pilot ARC Discussion, Procedure Recommendations

Page 19

B-6

OPERATION

B-6

 

 

 

PILOT ARC DISCUSSION

The PRO-CUT has a smooth, continuous pilot arc. The pilot arc is only a means of transferring the arc to the workpiece for cutting. Repeated pilot arc starts, in rapid succession, is not recommended as these starts will generally reduce consumable life. Occasionally, the pilot arc may sputter or start intermittently. This is aggravated when the consumables are worn or the air pressure is too high. Always keep in mind that the pilot arc is designed to transfer the arc to the work- piece and not for numerous starts without cutting.

When the pilot arc is started, a slight impulse will be felt in the torch handle. This occurrence is normal and is the mechanism which starts the plasma arc. This impulse can also be used to help troubleshoot a "no start" condition.

PROCEDURE RECOMMENDATIONS

When properly used, plasma arc cutting or gouging is a very economical process. Improper use will result in a very high operating cost.

General - In All Cases

Follow safety precautions as printed throughout this operating manual and on the machine.

Thin Gauge Sheet Metal:

Torch Standoff

Machine Output Setting

45

DRAG thru 1/16"

Output Setting

Standoff

Min. Range thru 45 Amps

1.Output set below 45 amps.

The nozzle may be dragged on the metal sur- face, touching it lightly to the surface after pierc- ing a hole. Current control should be set below the mid range.

Thick Sections of Metal

Torch Standoff

Machine Output Setting

45

1/8" thru 3/16"

Output Setting

Standoff

45 Amps thru Max. Range

1.Output set above 45 amps.

The best quality and consumable life will be obtained by holding the torch off the surface about 3/16". Too long an arc may compromise cut quality and consumable life. The nozzle should NOT be dragged on the work.

2.The nozzle should not be dragged on the work surface.

Dragging the nozzle on the work surface will result in shortened consumable life

Use of the S22151 Drag Cup will maintain the proper standoff and eliminate nozzle double arcing.

If piercing is required, slowly lower the torch at an angle of about 30° to blow the dross away from the torch tip and slowly rotate the torch to a vertical position as the arc becomes deeper. This process will blow a lot of molten metal and dross. Be careful! Blow the dross away from the torch, the operator and any flammable objects.

Where possible, start the cut from the edge of the work piece.

Keep moving! A steady speed is necessary. Do not pause.

Do not allow torch cable or body to contact hot surface.

2.Current Control should be set below the mid range.

Do not allow cable or body to contact hot sur- face.

PRO-CUT 55

Image 19
Contents PRO-CUTTM55 Electric Shock can kill SafetyPlasma ARC can injure Page Sûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Vii Technical Specifications PRO-CUT InstallationThree Phase Single Phase Select Proper Location Safety PrecautionsHigh Frequency Interference Protection Input Power Cord Connector Installation Single Phase Input Connection for 208/230/460 Volt MachinesInput Electrical Connections USE on Engine Driven Power Supplies Input Voltage Reconnection ProcedureFrame Grounding Output Connections GAS Input ConnectionsOperation Preheat Temperature for Plasma CuttingDescription Recommended Processes and Equipment Operational Features and ControlsDesign Features Advantages User ResponsibilityConsumable Life Cutting CapabilityLimitations Controls and SettingsSafety LED Pilot ARC Discussion Procedure RecommendationsSuggestions for Extra Utility from the PRO-CUT System General Options Accessories AccessoriesInput Filter Capacitor Discharge Procedure MaintenancePeriodic Maintenance Routine MaintenanceHOW to USE Troubleshooting Guide TroubleshootingElectric Shock can Kill Troubleshooting Field Service Facility Troubleshooting Problems Possible Recommended Symptom Check If the Safety LED is LIT and STEADY, perform the following Consumable Related Safety LED TroubleshootingWiring Diagram PRO-CUT 55 Codes 10475, 10476, 10571 Diagrams Wiring Diagram Codes 11013 Wiring Diagram Codes 11011, 11012, 11015 Dimension Print PRO-CUT PRO-CUT PRO-CUT Precaucion Warnung