OPTIONAL EQUIPMENT (Field Installed)

Four Wheel Undercarriage (K933-1) - Allows move- ment of the Ranger 8 by hand without lifting. Easily assembles to the Ranger 8. Includes two rugged, hard molded wheels and two durable, two ply nylon 4.80/4.00-8 pneumatic tires rated at 30 psi. The spring loaded handle provides convenient, comfortable steer- ing. The undercarriage comes equipped with a sturdy frame that is capable of supporting the weight of the machine. K934-1 and K934-2 brackets are available for mounting gas cylinders on the undercarriage.

Bracket for Mounting a Gas Cylinder or a LPG Fuel Cylinder to a K933-1 (K934-1) - Easily mounts on the back of the K933-1 Four Wheel Undercarriage to carry either a welding gas cylinder or a lift truck type LPG fuel cylinder with a capacity of 33.5 lbs. or 43.5 lbs. of fuel.

Bracket for Mounting a Welding Gas Cylinder and a LPG Fuel Cylinder to a K933-1 (K934-2) - Easily mounts on the back of the K933-1 Four Wheel Undercarriage to carry both a welding gas cylinder and a lift truck type LPG fuel cylinder with a capacity of 33.5 lbs. or 43.5 lbs. of fuel.

Canvas Cover (K886-1)- To protect the Ranger 8 when not in use. Made from attractive red canvas material which is flame retardant, mildew resistant, and water repellent.

Power Plug Kit (K802-R)- Provides four 115V plugs rated at 15 amps each and one dual voltage, full kVA plug rated at 115/230V, 50 amps.

Accessory Kit (K710) - Includes 30 ft (9.1m) 3 AWG electrode cable, 25 ft. (7.6m) 3 AWG work cable, headshield with No. 12 filter, GC300 work clamp and Cooltong® 300 electrode holder. Cables are rated at 225 amps, 40% duty cycle.

Remote Control Receptacle Kit (K892-1) - Includes

a6-pin MS-type (Amphenol) receptacle and a local- remote toggle switch that mounts in the case front. Requires a Remote Control Option.

Remote Control (K857) - Consists of a control box with 25 ft. (7.5m) of four conductor cable. Permits remote adjustment of output voltage. (Requires Remote Control Receptacle Kit to be mounted in machine.)

Spark Arrester Kit (K894-1) - Includes a heavy gauge steel, approved spark arrester and clamp for easy mounting to muffler exhaust pipe.

GFCI Receptacle Kit (K896-1) - Includes two UL approved 115V ground fault circuit interrupter duplex type receptacles with covers and installation instruc- tions. Replaces the two factory installed 115V duplex receptacles. Each receptacle of each GFCI duplex is rated at 15 amps, but the maximum total current from each GFCI duplex is limited to 20 amps.

TIG Module (K930-1) - Provides high frequency and shielding gas control for AC and DC GTAW (TIG) welding applications. Compact case is designed for easy carrying, complete with handle. High frequency bypass is built in. The K938-1 Contactor Kit must be field installed in the TIG Module when used with a Ranger 8. For use of optional Amptrol, the K892-1 Remote Control Receptacle Kit must be installed in the Ranger 8. The K939-1 Docking Kit is available for mounting the TIG Module on top of the Ranger 8. The K936-3 control cable is required if remote control is used. The K936-4 control cable is required if remote control is not used.

RANGER 8 LPG

Image 11
Contents Ranger LPG California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéRanger 8 LPG Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents General Description Design FeaturesOther Features Auxiliary PowerEngine SpecificationsMachine Output Remote Control Receptacle Kit K892-1 Includes Optional Equipment Field InstalledTIG Wire FeedRecommended Equipment StickTrailers Installation InstructionsSafety Precautions Spark ArresterOil Pre-Operation ServiceLPG- fuel can cause fire or explosion FuelAWG Welding Output CablesHigh Altitude Operation Angle of Operation Location / VentilationInstructions OperatingWelder Controls Function and Operation Engine ON-OFF SwitchEngine Start Push-Button Switch Idler SwitchStick Constant Current Welding Break-in PeriodWelding Process Stopping the Engine115V Duplex Receptacles Auxiliary PowerWire Feed Welding Processes Constant Voltage Summary of Welding Processes115/230 Volt Dual Voltage Receptacle Auxiliary Power While WeldingSimultaneous Welding and Power Standby Power ConnectionsConnection of Ranger 8 to Premises Wiring Type Common Electrical Devices Possible Concerns Table A.2 Electrical Device USE with the Ranger 8 LPGOverspeed is Hazardous MaintenanceCH20S Champion RC12YC Fram CA79Trouble Cause What to do TroubleshootingTroubleshooting CCW Wiring DiagramLPG DiagramsRanger 8 LPG Code 10937 only Onan / Kohler CSA Ranger 8 / LN-25 Across the ARC Connection Diagram Connection DiagramsPrint DimensionDimension Print Ranger 8 LPG Kohler Ranger 8 LPG Ranger 8 LPG Ranger 8 LPG Basic Course How To Read Shop DrawingsNew Lessons in Arc Welding Need Welding Training?Precaucion Warnung