13

13

It is recommended that the Ranger 8 be used in HIGH idle when using the TIG Module. It can be used in the AUTO position but the delay going to low idle after welding is ceased will be increased if the AFTER- FLOW CONTROL is set above 10 seconds.

Wire Feed Welding Processes

(Constant Voltage)

The only Innershield® electrode recommended for use with the Ranger 8 is NR®-211-MP. The electrode sizes and welding ranges that can be used with the Ranger 8 are shown in the following table:

Diameter

Wire Speed

Approximate

(in.)

Range In./Min.

Current Range

 

 

 

 

.035

80

- 110

75A to 120A

.045

70

- 130

120A to 170A

.068

40

- 90

125A to 210A

 

 

 

 

The Ranger 8 is recommended for limited “MIG” weld- ing (GMAW - gas metal arc welding). The recom- mended electrodes are .030” and .035” L-50 and L-

56.They must be used with a blended shielding gas such as C25 (75% Argon - 25% CO2). The welding

ranges that can be used with the Ranger 8 are shown in the following table:

Diameter

Wire Speed

Approximate

(in.)

Range In./Min.

Current Range

 

 

 

.030

80-110

75A to 120A

.035

70-130

120A to 170A

 

 

 

Summary of Welding Processes

 

CONTROL

 

ELECTRODE

 

 

CABLE

IDLE

WHEN NOT

TO START

PROCESS

USED

MODE

WELDING

WELDING

 

 

 

 

 

STICK

No

AUTO

Hot

Touch electrode to work.

 

 

 

 

Welding starts immediately

 

 

 

 

and engine goes to high

 

 

 

 

idle.

 

 

 

 

 

TIG/K930-1/K938-1/

Yes

HIGH

Cold

Press Amptrol, contactor

K936-[ ]/K892-1

 

 

 

closes, welding starts

(WITH AMPTROL)

 

 

 

immediately.

 

 

 

 

 

WIRE FEED, LN-25 WITH

No

AUTO

Cold

Press gun trigger, LN-25

INTERNAL CONTACTOR

 

 

 

contactor closes. Welding

 

 

 

 

starts immediately and

 

 

 

 

engine goes to high idle.

 

 

 

 

NOTE: Output Control

 

 

 

 

must be set above “3”.

 

 

 

 

 

WIRE FEED, LN-7 WITH

Yes

HIGH

Cold

Press gun trigger,

K240 CONTACTOR KIT

 

 

 

contactor closes. Welding

 

 

 

 

starts immediately.

 

 

 

 

 

Auxiliary Power

The Ranger 8 can provide up to 8,000 watts of 115/230 volts AC, single phase 60 Hz power for con- tinuous use. The front of the machine includes three receptacles for connecting AC power plugs; one 50 amp 115/230 volt NEMA 14-50R receptacle and two 15 amp on (Codes 10541 Below), 20 amp on (Codes 10937 Above) 115 volt NEMA 5-15R recepta- cles.

CAUTION

Do not connect any plugs that connect to the power receptacles in parallel.

-----------------------------------------------------------------------

Start the engine and set the “IDLER” control switch to the desired operating mode. Set the “CONTROL” to

10.Voltage is now correct at the receptacles for aux- iliary power.

115V Duplex Receptacles

The 115V auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs.

RANGER 8 LPG

Image 20
Contents Ranger LPG Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately Ranger 8 LPGTable of Contents Design Features Other FeaturesAuxiliary Power General DescriptionEngine SpecificationsMachine Output Optional Equipment Field Installed Remote Control Receptacle Kit K892-1 IncludesWire Feed Recommended EquipmentStick TIGInstallation Instructions Safety PrecautionsSpark Arrester TrailersPre-Operation Service LPG- fuel can cause fire or explosionFuel OilWelding Output Cables AWGAngle of Operation Location / Ventilation High Altitude OperationOperating InstructionsEngine ON-OFF Switch Engine Start Push-Button SwitchIdler Switch Welder Controls Function and OperationBreak-in Period Welding ProcessStopping the Engine Stick Constant Current WeldingAuxiliary Power Wire Feed Welding Processes Constant VoltageSummary of Welding Processes 115V Duplex ReceptaclesAuxiliary Power While Welding Simultaneous Welding and PowerStandby Power Connections 115/230 Volt Dual Voltage ReceptacleConnection of Ranger 8 to Premises Wiring Table A.2 Electrical Device USE with the Ranger 8 LPG Type Common Electrical Devices Possible ConcernsOverspeed is Hazardous MaintenanceCH20S Fram CA79 Champion RC12YCTroubleshooting Trouble Cause What to doTroubleshooting Wiring Diagram CCWLPG DiagramsRanger 8 LPG Code 10937 only Onan / Kohler CSA Connection Diagrams Ranger 8 / LN-25 Across the ARC Connection DiagramPrint DimensionDimension Print Ranger 8 LPG Kohler Ranger 8 LPG Ranger 8 LPG Ranger 8 LPG How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? Basic CoursePrecaucion Warnung