It is recommended that the Ranger 8 be used in HIGH idle when using the TIG Module. It can be used in the AUTO position but the delay going to low idle after welding is ceased will be increased if the AFTER- FLOW CONTROL is set above 10 seconds.
Wire Feed Welding Processes
(Constant Voltage)
The only Innershield® electrode recommended for use with the Ranger 8 is
Diameter | Wire Speed | Approximate | |
(in.) | Range In./Min. | Current Range | |
|
|
|
|
.035 | 80 | - 110 | 75A to 120A |
.045 | 70 | - 130 | 120A to 170A |
.068 | 40 | - 90 | 125A to 210A |
|
|
|
|
The Ranger 8 is recommended for limited “MIG” weld- ing (GMAW - gas metal arc welding). The recom- mended electrodes are .030” and .035”
56.They must be used with a blended shielding gas such as C25 (75% Argon - 25% CO2). The welding
ranges that can be used with the Ranger 8 are shown in the following table:
Diameter | Wire Speed | Approximate |
(in.) | Range In./Min. | Current Range |
|
|
|
.030 | 75A to 120A | |
.035 | 120A to 170A | |
|
|
|
Summary of Welding Processes
| CONTROL |
| ELECTRODE |
|
| CABLE | IDLE | WHEN NOT | TO START |
PROCESS | USED | MODE | WELDING | WELDING |
|
|
|
|
|
STICK | No | AUTO | Hot | Touch electrode to work. |
|
|
|
| Welding starts immediately |
|
|
|
| and engine goes to high |
|
|
|
| idle. |
|
|
|
|
|
Yes | HIGH | Cold | Press Amptrol, contactor | |
|
|
| closes, welding starts | |
(WITH AMPTROL) |
|
|
| immediately. |
|
|
|
|
|
WIRE FEED, | No | AUTO | Cold | Press gun trigger, |
INTERNAL CONTACTOR |
|
|
| contactor closes. Welding |
|
|
|
| starts immediately and |
|
|
|
| engine goes to high idle. |
|
|
|
| NOTE: Output Control |
|
|
|
| must be set above “3”. |
|
|
|
|
|
WIRE FEED, | Yes | HIGH | Cold | Press gun trigger, |
K240 CONTACTOR KIT |
|
|
| contactor closes. Welding |
|
|
|
| starts immediately. |
|
|
|
|
|
Auxiliary Power
The Ranger 8 can provide up to 8,000 watts of 115/230 volts AC, single phase 60 Hz power for con- tinuous use. The front of the machine includes three receptacles for connecting AC power plugs; one 50 amp 115/230 volt NEMA
CAUTION
Do not connect any plugs that connect to the power receptacles in parallel.
Start the engine and set the “IDLER” control switch to the desired operating mode. Set the “CONTROL” to
10.Voltage is now correct at the receptacles for aux- iliary power.
115V Duplex Receptacles
The 115V auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs.