Lincoln Electric IM604-B manual Welding Output Cables, Awg

Page 15

8

8

Battery Connections

This welder is shipped with the negative battery cable disconnected. Make sure that the Engine Switch is in the “OFF” position and attach the disconnected cable securely to the negative battery terminal before attempting to operate the machine. If the battery is discharged and does not have enough power to start the engine, see the battery charging instructions in the Battery section.

Welding Output Cables

With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if neces- sary. Loose connections will result in overheating of the output studs.

When welding at a considerable distance from the welder, be sure you use ample size welding cables. Listed below are copper cable sizes recommended for the rated current and duty cycle. Lengths stipulated are the distance from the welder to work and back to the welder again. Cable sizes are increased for greater lengths primarily for the purpose of minimizing cable voltage drop.

TOTAL COMBINED LENGTH OF

ELECTRODE AND WORK CABLES

0-50 Ft.

50-100 Ft.

100-150 Ft.

150-200 Ft.

225Amps

40% Duty Cycle

3AWG

3AWG

2AWG

1AWG

225Amps

100% Duty Cycle

1AWG

1AWG

1AWG

1AWG

200-250 Ft.

1/0 AWG

1/0 AWG

RANGER 8 LPG

Image 15
Contents Ranger LPG California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéRanger 8 LPG Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents General Description Design FeaturesOther Features Auxiliary PowerSpecifications MachineEngine Output Remote Control Receptacle Kit K892-1 Includes Optional Equipment Field InstalledTIG Wire FeedRecommended Equipment StickTrailers Installation InstructionsSafety Precautions Spark ArresterOil Pre-Operation ServiceLPG- fuel can cause fire or explosion FuelAWG Welding Output CablesHigh Altitude Operation Angle of Operation Location / VentilationInstructions OperatingWelder Controls Function and Operation Engine ON-OFF SwitchEngine Start Push-Button Switch Idler SwitchStick Constant Current Welding Break-in PeriodWelding Process Stopping the Engine115V Duplex Receptacles Auxiliary PowerWire Feed Welding Processes Constant Voltage Summary of Welding Processes115/230 Volt Dual Voltage Receptacle Auxiliary Power While WeldingSimultaneous Welding and Power Standby Power ConnectionsConnection of Ranger 8 to Premises Wiring Type Common Electrical Devices Possible Concerns Table A.2 Electrical Device USE with the Ranger 8 LPGMaintenance CH20SOverspeed is Hazardous Champion RC12YC Fram CA79Trouble Cause What to do TroubleshootingTroubleshooting CCW Wiring DiagramDiagrams Ranger 8 LPG Code 10937 only Onan / Kohler CSALPG Ranger 8 / LN-25 Across the ARC Connection Diagram Connection DiagramsDimension Dimension Print Ranger 8 LPG KohlerPrint Ranger 8 LPG Ranger 8 LPG Ranger 8 LPG Basic Course How To Read Shop DrawingsNew Lessons in Arc Welding Need Welding Training?Precaucion Warnung