Lincoln Electric IM604-B manual Operating, Instructions

Page 17

10

10

Connection of the LN-7 to the Ranger 8

OPERATING

a. Shut the welder off.

INSTRUCTIONS

 

b. Connect the LN-7 and the K240 contactor kit per

Additional Safety Precautions

 

instructions on the connection diagram S17742

Always operate the welder with the roof and case

(can be found in the back of this manual).

sides in place as this provides maximum protection

 

c. Place the “RANGE” switch to the “WIRE FEED”

from moving parts and assures proper cooling air flow.

 

position and the “POLARITY” switch to the

Do not tamper with the carburetor settings or the fuel

desired polarity.

hose from the regulator to the carburetor. The engine

 

d. Place the “IDLER” switch in the “HIGH” idle

has been pre-set for optimum performance. Changes

in the carburetor settings or fuel hose length can

position. The engine idling device may not

result in reduced performance and excessive carbon

function when welding in the “WIRE FEED” mode.

monoxide emmisions.

 

e. Adjust wire feed speed at the LN-7 and adjust the

Read and understand all Safety Precautions before

welding voltage with the output “CONTROL” at

operating this machine. Always follow these and any

the welder.

other safety procedures included in this manual and in

NOTE: If the output “CONTROL” is set below “3” the

the Engine Owner’s Manual.

K240 contactor may not pull in.

 

Connection of TIG Module (K930-1) to the Ranger 8

The TIG Module is an accessory that provides high frequency and shielding gas control for AC and DC GTAW (TIG) welding. See IM528 supplied with the TIG Module for installation instructions.

Note: The TIG Module does not require the use of a high frequency bypass capacitor. If any other high frequency accessory is used with the Ranger 8, a bypass capacitor (Order Kit T12246) must be installed in the Ranger 8.

Welder Operation

Welder Output

Maximum Open Circuit Voltage at 3700 RPM is 80 Volts RMS.

Duty Cycle: 100% for both welding and auxiliary power.

Ranger 8 LPG

Constant Current

225 Amps AC @ 25 Volts

 

 

210 Amps DC @ 25 Volts

 

 

 

Constant Voltage

200 Amps DC @ 20 Volts

 

 

 

Ranger 8 LPG Typical Fuel Consumption

 

KOHLER CH20S

 

COMMAND®

 

 

Low Idle - No Load

1.60 lb/Hour

(0.73 kg/Hour)

 

High Idle - No Load

2.40 lb/Hour

(1.09 kg/Hour)

 

 

 

 

1/2 Load

5.40 lb/Hour

(2.45 kg/Hour)

 

 

 

3/4 Load

7.00 lb/Hour

(3.18 kg/Hour)

 

 

 

Full Load

8.50 lb/Hour

(3.86 kg/Hour)

 

 

 

 

RANGER 8 LPG

Image 17
Contents Ranger LPG California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding Sparks can cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE SûretéRanger 8 LPG Please Examine Carton and Equipment For Damage ImmediatelyTable of Contents Other Features Design FeaturesAuxiliary Power General DescriptionEngine SpecificationsMachine Output Remote Control Receptacle Kit K892-1 Includes Optional Equipment Field InstalledRecommended Equipment Wire FeedStick TIGSafety Precautions Installation InstructionsSpark Arrester TrailersLPG- fuel can cause fire or explosion Pre-Operation ServiceFuel OilAWG Welding Output CablesHigh Altitude Operation Angle of Operation Location / VentilationInstructions OperatingEngine Start Push-Button Switch Engine ON-OFF SwitchIdler Switch Welder Controls Function and OperationWelding Process Break-in PeriodStopping the Engine Stick Constant Current WeldingWire Feed Welding Processes Constant Voltage Auxiliary PowerSummary of Welding Processes 115V Duplex ReceptaclesSimultaneous Welding and Power Auxiliary Power While WeldingStandby Power Connections 115/230 Volt Dual Voltage ReceptacleConnection of Ranger 8 to Premises Wiring Type Common Electrical Devices Possible Concerns Table A.2 Electrical Device USE with the Ranger 8 LPGOverspeed is Hazardous MaintenanceCH20S Champion RC12YC Fram CA79Trouble Cause What to do TroubleshootingTroubleshooting CCW Wiring DiagramLPG DiagramsRanger 8 LPG Code 10937 only Onan / Kohler CSA Ranger 8 / LN-25 Across the ARC Connection Diagram Connection DiagramsPrint DimensionDimension Print Ranger 8 LPG Kohler Ranger 8 LPG Ranger 8 LPG Ranger 8 LPG New Lessons in Arc Welding How To Read Shop DrawingsNeed Welding Training? Basic CoursePrecaucion Warnung