GENERAL DESCRIPTION

The Ranger8 LPG is a twin-cylinder LPG fuel engine driven multiprocess arc welder and AC power genera- tor. It is built in a heavy gauge steel case for durability on the job site.

DESIGN FEATURES

AC/DC STICK WELDING (Constant Current)

AC 40 - 225 Amps

DC 40 - 210 Amps

100% Duty Cycle on All Settings

Output Selector with 6 Ranges

Output Control for Fine Current Adjustment

Use with a broad range of AC & DC Electrodes Including Fleetweld® 5P

DC SEMIAUTOMATIC WIRE FEED WELDING (Constant Voltage)

CV Tap Setting for 60-200 Amps.

100% Duty Cycle.

Excellent Performance with .068” (1.7mm) NR®-211-MP Innershield® Electrode.

Limited MIG Welding with L-50 & L-56 using blended Argon Shielding Gas.

The Recommended Wire Feeder is the LN-25, but Can Also be Used with the LN-7 Wire Feeder. (LN-7 and LN-25 without Contactor Requires the K240 Contactor Kit).

AC/DC TIG WELDING (Constant Current)

AC & DC TIG Welding Can be Done at All Constant Current Output Range Settings.

AUXILIARY POWER

8000 Watt AC 115/230 Volt 60 Hz. Generator.

Operates AC Power Tools.

Powers Battery Chargers.

Powers a 1.5 HP Motor (If Started Under No Load).

Lights Eighty 100 Watt Incandescent Bulbs.

Can be Used for Standby Power.

OTHER FEATURES

Polarity Switch for Selecting DC+, DC-, or AC Welding Output.

K930-1 TIG Module Available for high frequency and shielding gas control for AC and DC GTAW (TIG) welding applications.

Remote Control Receptacle Kit Available.

Electronic Engine Idler. Engine Automatically Goes to Low Idle in 10 to 14 Seconds after Welding or Use of Auxiliary Power. Includes High Idle Switch.

Electric Starting.

Battery Charging Ammeter.

Full 8 kVA Auxiliary Output Receptacle.

Factory Installed Engine Hour Meter.

Engine Protection Shuts Engine Down in the Event of Low Oil Pressure.

Built-in Feet for Easy Mounting to Truck Bed or Trailer.

All Copper Alternator Windings and High Quality Insulation for Long-Life and Dependability.

Powder Painted Case and Base for Outstanding Corrosion Protection.

Quiet muffler with reversible exhaust feature; either right or left side of machine.

ENGINE

The Kohler 20 HP Command®* LPG engine offers the following features:

Air Cooled, Twin-Cylinder.

Overhead valves

Hydraulic valve lifters

Cast Aluminum Alloy Crankcase with Integral Cast Iron Cylinder Liners.

Electric Start with Solid State Battery Charging Module.

Solid State Breakerless Ignition.

Spin on Oil Filter.

Low Oil Pressure Shutdown Protection.

LPG regulator and vaporizer.

* This trademark is the property of Kohler Co.

RANGER 8 LPG

Image 8
Contents Ranger LPG Safety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcPlease Examine Carton and Equipment For Damage Immediately Ranger 8 LPGTable of Contents Design Features Other FeaturesAuxiliary Power General DescriptionEngine SpecificationsMachine Output Optional Equipment Field Installed Remote Control Receptacle Kit K892-1 IncludesWire Feed Recommended EquipmentStick TIGInstallation Instructions Safety PrecautionsSpark Arrester TrailersPre-Operation Service LPG- fuel can cause fire or explosionFuel OilWelding Output Cables AWGAngle of Operation Location / Ventilation High Altitude OperationOperating InstructionsEngine ON-OFF Switch Engine Start Push-Button SwitchIdler Switch Welder Controls Function and OperationBreak-in Period Welding ProcessStopping the Engine Stick Constant Current WeldingAuxiliary Power Wire Feed Welding Processes Constant VoltageSummary of Welding Processes 115V Duplex ReceptaclesAuxiliary Power While Welding Simultaneous Welding and PowerStandby Power Connections 115/230 Volt Dual Voltage ReceptacleConnection of Ranger 8 to Premises Wiring Table A.2 Electrical Device USE with the Ranger 8 LPG Type Common Electrical Devices Possible ConcernsOverspeed is Hazardous MaintenanceCH20S Fram CA79 Champion RC12YCTroubleshooting Trouble Cause What to doTroubleshooting Wiring Diagram CCWLPG DiagramsRanger 8 LPG Code 10937 only Onan / Kohler CSA Connection Diagrams Ranger 8 / LN-25 Across the ARC Connection DiagramPrint DimensionDimension Print Ranger 8 LPG Kohler Ranger 8 LPG Ranger 8 LPG Ranger 8 LPG How To Read Shop Drawings New Lessons in Arc WeldingNeed Welding Training? Basic CoursePrecaucion Warnung