27 | 27 |
CALIBRATION
ROBOTIC PW450 CURRENT CALIBRATION (continued)
Figure 10 – TEST AND CALIBRATION OVERLAY
(32) | (33) | (128) | (129) |
(34) | (35) | (130) | (131) |
(36) (37)
(96)(98)(100)
(64)(65)
(67) | (97) | (99) | (101) | (132) | (133) |
|
|
|
|
|
PROCEDURE
1.Install the Test and Calibration Overlay and apply power to the machine. See Figure 10.
2.Press the Manual Procedure Entry Key (64). The machine should display the following:
PROCESS 1 SETUP
3.Toggle the Arrow Keys (100 and 101) until the display reads:
PROCESS 1 SETUP
4.Trigger the PW450 and apply the load. (See EXTERNAL TRIGGERING CIRCUIT) on the next page.
WARNING
The machine’s output terminals will be electri- cally “HOT” when the trigger circuit is activated.
5.Adjust the potentiometer until the reference (external ammeter) reads 304 amps +/- 1.0 amps. The load voltage should be greater than 15 volts but less than 35 volts.
6.Remove power to the machine.
7.If necessary
8.Replace the machine case parts.
POWER