Lincoln Electric IM573 manual Setup for Power Wave 450 After Display Board Replacement

Page 8

8

8

CALIBRATION

SETUP FOR POWER WAVE 450 AFTER DISPLAY BOARD REPLACEMENT

WARNING

Service and repair should be performed by only Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock, please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 1-800-833-9353 (WELD).

SETUP DESCRIPTION

This procedure properly enables the work and electrode sense leads after Display Board replacement.

MATERIALS NEEDED

Set-Up Overlay – L9660

Setting up the SemiAutomatic Power Wave 450 after Display Board replacement

After a Display board is installed, all users should veri- fy the polarity, sense lead and water cooler conditions. Proceed as follows:

1.Insert the SETUP Overlay (L9660) and turn the Power Wave on.

2.For the majority of applications, the wire feeder LED’s should look as follows (change settings as required to suit special applications):

Wire Feeder 1

Wire Feeder 2

Polarity LED “ON”

Polarity LED “ON”

Electrode Sense Lead Enabled

Electrode Sense Lead Enabled

LED “ON”

LED “ON”

Work Sense Lead Enabled

Work Sense Lead Enabled

LED “OFF”

LED “OFF”

3.If an external work sense lead (21 lead) is used, turn on the WORK SENSE LEAD ENABLED LED on WIRE FEEDER 1.

4.If a water cooler is used, enable and prime the water cooler using the water cooler SETUP keys.

5.Power down and remove the overlay.

Setting up the Robotic Power Wave 450 after Display Board replacement

After a Display board is installed, a special setup pro- cedure is required to properly initialize the machine for robotic use. Proceed as follows:

1.Insert the SETUP Overlay (L9660) and turn the Power Wave on.

2.The Wire Feeder 1 + POLARITY LED should be on when the machine is first powered up. If not, proceed to step 4.

3.Turn the + POLARITY LED for WIRE FEEDER 1 off by pressing the +/- POLARITY KEY for WIRE FEEDER 1. Note that WIRE FEEDER 2 LEDs will also change during this procedure.

4.Turn the + POLARITY LED for WIRE FEEDER 1 back on by again pressing the +/- POLARITY KEY for WIRE FEEDER 1.

5.When done properly, the LEDs should look as follows:

Wire Feeder 1

Wire Feeder 2

Polarity LED “ON”

Polarity LED “ON”

Electrode Sense Lead Enabled

Electrode Sense Lead Enabled

LED “ON”

LED “OFF”

Work Sense Lead Enabled

Work Sense Lead Enabled

LED “OFF”

LED “OFF”

6.If an external work sense lead (21 lead) is used, turn on the

WORK SENSE LEAD ENABLED LED on WIRE FEEDER 1.

7.If a water cooler is used, enable and prime the water cooler using the water cooler SETUP keys.

8.Power down and remove the overlay.

POWER WAVE CALIBRATION

Image 8
Contents Power Wave PC Board Replacement Calibration Procedures Index of Procedures CalibrationPower Wave PC Board Replacement Calibration Procedures Electric Shock Can KillMaterials Needed Capacitor Discharge ProcedurePurpose for the Procedure Test Procedure Resistor LocationsH a R G E Resistor with Leads Connected Setup for Power Wave 450 After Display Board Replacement Setup DescriptionSensor Calibration Test for Display Board Test DescriptionProcedure Insert REF Ovrly Press EnterProcedure Description Semiautomatic PW450 Quick Voltage CalibrationSemiautomatic PW450 Quick Voltage Calibration Robotic PW450 Quick Voltage Calibration Robotic PW450 Quick Voltage Calibration Setup Procedure Semiautomatic PW450 Full Voltage CalibrationSemiautomatic PW450 Full Voltage Calibration Robotic PW450 Full Voltage Calibration Robotic PW450 Full Voltage Calibration Calibration Adjust to CALIBRATION# = +POLARITY +67B -POLARITY +21B Semiautomatic PW450 Current Calibration PC Board Removed but Still ConnectedSemiautomatic PW450 Current Calibration Process 1 Setup Robotic PW450 Current Calibration Robotic PW450 Current Calibration Procedure External Triggering Circuit Robot ReceptacleRobotic Interface P.C. Board Calibration Quick Shunt Board TestMiscellaneous Connections Power Wave Interface BoardArctool Welding Inputs and OUT- Puts Test Procedure After Repair