TROUBLESHOOTING
TROUBLESHOOTING GUIDE
Observe Safety Guidelines detailed throughout this manual.
ACCESSORIES
| SYMPTOM |
| CAUSE AND REMEDY |
|
| K870 Foot Amptrol or K963 Hand Amptrol. |
|
|
|
| Amptrol does not control welder output with | 1. | Check continuity between pins D and E in the cable connec- |
|
| Current Control switch in REMOTE and |
| tor. There should be an open circuit when the Amptrol is not |
|
| Mode switch in TIG. |
| pressed and a short circuit when it is pressed part way. If this |
|
|
|
| is not the case, check the Amptrol cable for breaks. The |
|
|
|
| microswitch in the Amptrol may not be operating properly. |
|
|
|
| Repair or replace as necessary. |
|
|
| 2. | Using an ohmmeter, check the resistance between pins A |
|
|
|
| and B in the Amphenol connector. The resistance should be |
|
|
|
| 10K ohms when the pedal is up, and near zero ohms when |
|
|
|
| the pedal is fully depressed. An open circuit would indicate a |
|
|
|
| bad cable or defective potentiometer. Check for breaks and |
|
|
|
| repair or replace the damaged cable or potentiometer. |
|
|
|
|
|
|
| K814 Arc Start Switch |
|
|
|
| Arc Start Switch does not start welder output | 1. | Check continuity between pins D and E of the cable |
|
| in TIG Mode and LOCAL Current Control. |
| connector. There should be an open circuit when the switch |
|
|
|
| is not pressed, and a short circuit when the switch is |
|
|
| pressed. |
| |
|
|
| Check the cable for breaks, and repair or replace as |
|
|
|
| necessary. Check the switch and its connections. |
|
|
| 2. | Be sure the |
|
|
|
|
|
|
| K846 Interface Kit |
|
|
|
| Solid State Relay Module output does not close | 1. | Is the correct type of solid state relay module installed? AC |
|
| when corresponding Status PC board LED lights. |
| modules work only for AC circuits, and DC modules only for |
|
|
|
| DC circuits. |
|
|
| 2. | Is the corresponding fuse (F1 for CR1, F2 for CR2, etc.) |
|
|
|
| blown? If so, find cause and replace with a 4 amp fuse. |
|
|
| 3. | Are the Interface and Status PC boards correctly mated to |
|
|
|
| one another? Be sure that all 10 pins on P701 are inserted |
|
|
|
| into J602 on the Status PC board. |
|
|
| 4. | Is harness connector P601 plugged into J701 on the |
|
|
|
| Interface PC board? |
|
|
| 5. | Is Terminal Strip (TS701) wired correctly (terminals 3 and 4 |
|
|
|
| for CR1, terminals 5 and 6 for CR2, etc.)? |
|
|
| 6. | Is DC polarity of terminal strip connection correct? Odd num- |
|
|
|
| bers (+), even numbers |
|
|
| 7. | Defective solid state relay. Replace. |
|
|
|
|
|
|
| Solid State Relay Module output seems to | 1. | High Frequency pickup may be a problem. Reroute leads |
|
| make contact at wrong times. |
| going to Interface terminal strip away from welding cables |
|
|
|
| which carry high frequency. |
|
|
| 2. | Use shielded cables to make connections to the Interface PC |
|
|
|
| board terminal strip. Ground the shield to terminal 1 or 2 on |
|
|
|
| TS701. |
|
|
| 3. | Be sure that the white ground lead is on the Interface PC |
|
|
|
| board tab terminal and is connected to the welder chassis |
|
|
|
| screw. |
|
|
|
|
|
|
SQUARE WAVE TIG 355