Lincoln Electric IM467-B manual Precaucion

Page 50

WARNING

Do not touch electrically live parts or

Keep flammable materials away.

Wear eye, ear and body protection.

Insulate yourself from work and

 

 

 

electrode with skin or wet clothing.

 

 

 

ground.

 

 

 

 

 

 

Spanish

No toque las partes o los electrodos

Mantenga el material combustible

Protéjase los ojos, los oídos y el

AVISO DE

bajo carga con la piel o ropa moja-

fuera del área de trabajo.

cuerpo.

PRECAUCION

da.

 

 

Aislese del trabajo y de la tierra.

 

 

 

 

 

 

French

Ne laissez ni la peau ni des vête-

Gardez à l’écart de tout matériel

Protégez vos yeux, vos oreilles et

ATTENTION

ments mouillés entrer en contact

inflammable.

votre corps.

avec des pièces sous tension.

 

 

 

Isolez-vous du travail et de la terre.

 

 

 

 

 

 

German

Berühren Sie keine stromführenden

Entfernen Sie brennbarres Material!

Tragen Sie Augen-, Ohren- und Kör-

WARNUNG

Teile oder Elektroden mit Ihrem

 

perschutz!

Körper oder feuchter Kleidung!

 

 

 

Isolieren Sie sich von den

 

 

 

Elektroden und dem Erdboden!

 

 

Portuguese

Não toque partes elétricas e elec-

Mantenha inflamáveis bem guarda-

Use proteção para a vista, ouvido e

ATENÇÃO

trodos com a pele ou roupa molha-

dos.

corpo.

da.

 

 

 

Isole-se da peça e terra.

 

 

 

 

 

 

Japanese

 

 

 

Chinese

Korean

Arabic

READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.

SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO Y LOS CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.

LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A ETRE EMPLOYES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLOYEUR.

LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER- STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.

Image 50
Contents Square Wave TIG Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Section E Section CSection D P196 SeriesInstallation Technical Specifications Square Wave TIGHigh Frequency Interference Protection Safety PrecautionsSelect Suitable Location Input Supply Connection Input ConnectionsGround Connection Electric Shock can killReconnect Procedure Figure A.2 Input Supply ConnectionsVolt/Freq Nameplate AWG Copper Cond Table A.1 Recommended Input Wire and Fuse SizesTable A.2 Recommended Input Wire and Fuse Sizes Volt/Freq AC Output AWG Copper CondLengths up to 100 to 200 ft 200 to 250 ft Output ConnectionsTIG Torch Connection 100 ft 30 m 30 to 61 m 61 to 76 mStick Electrode Cable Connection Safety Instructions Operating InstructionsGeneral Description Operational Features and ControlsDesign Features and Advantages Recommended ProcessesWelding Capability LimitationsControls and Settings Upper Case Front ControlsHigh Frequency Switch Mode SwitchSTEP/4-STEP Switch Upper Case Front Control PanelAC Wave Balance VOLTS/AMPS SwitchPeak Current Control Auto Balance LEDStart Controls Spot ControlsPulse Controls Figure B.2 Status Indicator Light Sequence Square Wave TIG Crater Fill ControlsOperation Lower Case Front Controls Figure B.3 Lower Case Frontcontrols Square Wave TIGOperation Hand and Foot Amptrol Operation Operation Stick Welding Welding OperationInitial START-UP TIG Welding GuidelinesIllustrated in the 2-Step Mode for clarity Table B.1 Specific Effects of ControlsCrater Fill Switch on OFFSpot Switch OFF Start Switch onPulse Switch on Crater Fill Switch on Spot Switch onTable B.2 Typical Current RANGES1 for Tungsten ELECTRODES2 Dcen Dcep + Unbalanced Wave Balanced WaveTable B.3 Recommended Settings for TIG Welding TIG Welding Sequence Operation 2-STEP ModeTIG Welding Sequence Operation 4-STEP Mode Polarity SwitchALL Machines Auxiliary PowerOverload Protection Accessories OPTIONS/ACCESSORIESMaintenance Input Power Factor Capacitor Discharge ProcedureRoutine and Periodic Maintenance Figure D.2 General Component Locations Troubleshooting Guide General Machine TroubleTroubleshooting Guide Stick Welding Symptom Cause and RemedyTroubleshooting Guide TIG Welding TIG Welding Lower Panel Controls Accessories K870 Foot Amptrol or K963 Hand AmptrolDiagrams Dimension Print Square Wave TIG355 Equipment Installation Certification Equipment MANUFACTURER’S CertificationPage Precaucion Aviso DE