Lincoln Electric IM467-B manual Electric Shock can kill

Page 3

ii

 

SAFETY

 

ii

 

 

 

 

 

 

 

 

 

ELECTRIC SHOCK can kill.

3.a. The electrode and work (or ground) circuits are electrically “hot” when the welder is on. Do not touch these “hot” parts with your bare skin or wet clothing. Wear dry, hole-free gloves to insulate hands.

3.b. Insulate yourself from work and ground using dry insulation. Make certain the insulation is large enough to cover your full area of physical contact with work and ground.

In addition to the normal safety precautions, if welding must be performed under electrically hazardous conditions (in damp locations or while wearing wet clothing; on metal structures such as floors, gratings or scaffolds; when in cramped positions such as sitting, kneeling or lying, if there is a high risk of unavoidable or accidental contact with the workpiece or ground) use the following equipment:

Semiautomatic DC Constant Voltage (Wire) Welder.

DC Manual (Stick) Welder.

AC Welder with Reduced Voltage Control.

3.c. In semiautomatic or automatic wire welding, the electrode, electrode reel, welding head, nozzle or semiautomatic welding gun are also electrically “hot”.

3.d. Always be sure the work cable makes a good electrical connection with the metal being welded. The connection should be as close as possible to the area being welded.

3.e. Ground the work or metal to be welded to a good electrical (earth) ground.

3.f. Maintain the electrode holder, work clamp, welding cable and welding machine in good, safe operating condition. Replace damaged insulation.

3.g. Never dip the electrode in water for cooling.

3.h. Never simultaneously touch electrically “hot” parts of electrode holders connected to two welders because voltage between the two can be the total of the open circuit voltage of both welders.

3.i. When working above floor level, use a safety belt to protect yourself from a fall should you get a shock.

3.j. Also see Items 6.c. and 8.

ARC RAYS can burn.

4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.

4.b. Use suitable clothing made from durable flame-resistant material to protect your skin and that of your helpers from the arc rays.

4.c. Protect other nearby personnel with suitable, non-flammable screening and/or warn them not to watch the arc nor expose themselves to the arc rays or to hot spatter or metal.

FUMES AND GASES can be dangerous.

5.a. Welding may produce fumes and gases hazardous to health. Avoid breathing these fumes and gases.When welding, keep your head out of the fume. Use enough ventilation and/or exhaust at the arc to keep

fumes and gases away from the breathing zone. When

welding with electrodes which require special ventilation such as stainless or hard facing (see instructions on container or MSDS) or on lead or cadmium plated steel and other metals or coatings which produce highly toxic fumes, keep exposure as low as possible and below Threshold Limit Values (TLV) using local exhaust or mechanical ventilation. In confined spaces or in some circumstances, outdoors, a respirator may be required. Additional precautions are also required when welding on galvanized steel.

5.b. Do not weld in locations near chlorinated hydrocarbon vapors coming from degreasing, cleaning or spraying operations. The heat and rays of the arc can react with solvent vapors to form phosgene, a highly toxic gas, and other irritating products.

5.c. Shielding gases used for arc welding can displace air and cause injury or death. Always use enough ventilation, especially in confined areas, to insure breathing air is safe.

5.d. Read and understand the manufacturer’s instructions for this equipment and the consumables to be used, including the material safety data sheet (MSDS) and follow your employer’s safety practices. MSDS forms are available from your welding distributor or from the manufacturer.

5.e. Also see item 1.b.

Mar ‘95

Image 3
Contents Square Wave TIG Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents P196 Series Section CSection D Section ETechnical Specifications Square Wave TIG InstallationSafety Precautions Select Suitable LocationHigh Frequency Interference Protection Electric Shock can kill Input ConnectionsGround Connection Input Supply ConnectionFigure A.2 Input Supply Connections Reconnect ProcedureVolt/Freq AC Output AWG Copper Cond Table A.1 Recommended Input Wire and Fuse SizesTable A.2 Recommended Input Wire and Fuse Sizes Volt/Freq Nameplate AWG Copper Cond100 ft 30 m 30 to 61 m 61 to 76 m Output ConnectionsTIG Torch Connection Lengths up to 100 to 200 ft 200 to 250 ftStick Electrode Cable Connection Operating Instructions Safety InstructionsRecommended Processes Operational Features and ControlsDesign Features and Advantages General DescriptionLimitations Welding CapabilityUpper Case Front Controls Controls and SettingsUpper Case Front Control Panel Mode SwitchSTEP/4-STEP Switch High Frequency SwitchAuto Balance LED VOLTS/AMPS SwitchPeak Current Control AC Wave BalanceSpot Controls Pulse ControlsStart Controls Crater Fill Controls Figure B.2 Status Indicator Light Sequence Square Wave TIGOperation Figure B.3 Lower Case Frontcontrols Square Wave TIG Lower Case Front ControlsOperation Hand and Foot Amptrol Operation Operation TIG Welding Guidelines Welding OperationInitial START-UP Stick WeldingTable B.1 Specific Effects of Controls Illustrated in the 2-Step Mode for clarityOFF Crater Fill Switch onSpot Switch on Start Switch onPulse Switch on Crater Fill Switch on Spot Switch OFFDcen Dcep + Unbalanced Wave Balanced Wave Table B.2 Typical Current RANGES1 for Tungsten ELECTRODES2Polarity Switch TIG Welding Sequence Operation 2-STEP ModeTIG Welding Sequence Operation 4-STEP Mode Table B.3 Recommended Settings for TIG WeldingAuxiliary Power Overload ProtectionALL Machines OPTIONS/ACCESSORIES AccessoriesInput Power Factor Capacitor Discharge Procedure MaintenanceRoutine and Periodic Maintenance Figure D.2 General Component Locations General Machine Trouble Troubleshooting GuideSymptom Cause and Remedy Troubleshooting Guide Stick WeldingTroubleshooting Guide TIG Welding TIG Welding Lower Panel Controls K870 Foot Amptrol or K963 Hand Amptrol AccessoriesDiagrams Dimension Print Square Wave TIG355 Equipment MANUFACTURER’S Certification Equipment Installation CertificationPage Precaucion Aviso DE