TECHNICAL SPECIFICATIONS - SQUARE WAVE TIG 355

INPUT - SINGLE PHASE ONLY

 

Input Voltages:

208

 

230

460

575

 

 

Input Currents

 

 

 

 

 

 

 

 

@ 350A/34 VDC

110

 

100

50

 

40

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATED OUTPUT

 

 

 

 

 

 

Duty Cycle

 

Amps

 

Volts at Rated Amperes

 

 

40% Duty Cycle

 

350

 

 

34 v

 

 

 

60% Duty Cycle

 

300

 

 

32 v

 

 

 

100% Duty Cycle

 

220

 

 

29 v

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

Maximum Open

 

Continuous

 

 

 

 

 

Circuit Voltage

 

Current Range

 

Auxiliary Power

 

 

 

80 Volts Max.

2-400 Amps AC and DC

 

115 VAC

 

 

 

 

 

 

 

 

 

 

15 Amps Continuous

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

For all Stick, DC TIG, and Balanced AC TIG

For Unbalanced AC TIG Welding Above 230 Amps,

 

 

 

 

Welding at 350A/34V/40% Duty Cycle Based

300/32V/60% Duty Cycle, Unbalance Based on the

 

 

 

 

on the 1990 U.S. National Electrical Code

 

1990 U.S. National Electrical Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type 75°C

 

 

Type 75°C

 

 

 

 

Fuse

Input

Type75°C

Copper Ground

 

Type 75°C

Copper Ground

Fuse

 

 

Input

(Super Lag)

Ampere

Copper Wire in

Wire in Conduit

 

Copper Wire in

Wire in Conduit

(Super LAG)

 

 

Voltage /

or Breaker

Rating on

Conduit AWG

AWG (IEC)

Input

Conduit AWG

AWG (IEC)

or Breaker

 

 

Frequency

Size

Nameplate

(IEC) Sizes

Sizes

Amperes

(IEC) Sizes

Sizes

Size

 

 

 

 

 

 

 

 

 

 

 

 

 

208/60

150

110

4 (25mm2)

6 (16mm2)

148

2 (35mm2)

6 (16mm2)

200

 

230/60

125

100

6 (16mm2)

6 (16mm2)

134

2 (35mm2)

6 (16mm2)

175

 

 

460/60

60

50

8 (10mm2)

10 (6mm2)

67

6 (16mm2)

8 (10mm2)

80

 

575/60

50

40

8 (10mm2)

10 (6mm2)

54

6 (16mm2)

8 (10mm2)

70

 

 

PHYSICAL DIMENSIONS

 

Height

Width

Depth

Weight

884 mm

565 mm

660 mm

232 kg

34.84 in.

22.25 in.

26.00 in.

510 lbs.

OPERATING TEMPERATURE RANGE STORAGE TEMPERATURE RANGE

0° to 40°C

-50° to 85°C

SQUARE WAVE TIG 355

Image 9
Contents Square Wave TIG Safety Electric Shock can kill Cylinder may explode if damaged Précautions DE Sûreté Thank You Table of Contents Section D Section CSection E P196 SeriesTechnical Specifications Square Wave TIG InstallationSafety Precautions Select Suitable LocationHigh Frequency Interference Protection Ground Connection Input ConnectionsInput Supply Connection Electric Shock can killFigure A.2 Input Supply Connections Reconnect ProcedureTable A.2 Recommended Input Wire and Fuse Sizes Table A.1 Recommended Input Wire and Fuse SizesVolt/Freq Nameplate AWG Copper Cond Volt/Freq AC Output AWG Copper CondTIG Torch Connection Output ConnectionsLengths up to 100 to 200 ft 200 to 250 ft 100 ft 30 m 30 to 61 m 61 to 76 mStick Electrode Cable Connection Operating Instructions Safety InstructionsDesign Features and Advantages Operational Features and ControlsGeneral Description Recommended ProcessesLimitations Welding CapabilityUpper Case Front Controls Controls and SettingsSTEP/4-STEP Switch Mode SwitchHigh Frequency Switch Upper Case Front Control PanelPeak Current Control VOLTS/AMPS SwitchAC Wave Balance Auto Balance LEDSpot Controls Pulse ControlsStart Controls Crater Fill Controls Figure B.2 Status Indicator Light Sequence Square Wave TIGOperation Figure B.3 Lower Case Frontcontrols Square Wave TIG Lower Case Front ControlsOperation Hand and Foot Amptrol Operation Operation Initial START-UP Welding OperationStick Welding TIG Welding GuidelinesTable B.1 Specific Effects of Controls Illustrated in the 2-Step Mode for clarityOFF Crater Fill Switch onPulse Switch on Crater Fill Switch on Start Switch onSpot Switch OFF Spot Switch onDcen Dcep + Unbalanced Wave Balanced Wave Table B.2 Typical Current RANGES1 for Tungsten ELECTRODES2TIG Welding Sequence Operation 4-STEP Mode TIG Welding Sequence Operation 2-STEP ModeTable B.3 Recommended Settings for TIG Welding Polarity SwitchAuxiliary Power Overload ProtectionALL Machines OPTIONS/ACCESSORIES AccessoriesInput Power Factor Capacitor Discharge Procedure MaintenanceRoutine and Periodic Maintenance Figure D.2 General Component Locations General Machine Trouble Troubleshooting GuideSymptom Cause and Remedy Troubleshooting Guide Stick WeldingTroubleshooting Guide TIG Welding TIG Welding Lower Panel Controls K870 Foot Amptrol or K963 Hand Amptrol AccessoriesDiagrams Dimension Print Square Wave TIG355 Equipment MANUFACTURER’S Certification Equipment Installation CertificationPage Precaucion Aviso DE