A-4 INSTALLATIONA-4
CONNECTION DIAGRAM, CONTROL
CABLE MODELS ( See Figure A.1) | FIGURE A.1 |
|
GUNS AND CABLES ASSEMBLIES
A variety of Lincoln 10' (3.0m) or 15' (4.6m) gun and cable assemblies are available for use with the
The
Gun Cable Connection to the Feeder
Lay the cable out straight. Insert the connector on the welding conductor cable into the brass bushing on the front of the wire drive unit. Keep the all mating sur- faces clean. Make sure it is fully seated and tighten the thumb screw.
Connect the control cable plug into the 5 pin recepta- cle on the front panel of the wire feeder.
ELECTRODE POLARITY
The
CONTROL CABLE CONNECTIONS
For Control Cable model, attach the control cable from the
Table A.2 Trigger Connector J1 (5 Pin)
PIN | Lead # | Function |
A | 556 | Trigger |
B | - | Not used |
C | 554 | Trigger/ 83% |
|
| Procedure ground |
D | 555 | 83% Procedure |
E | 554 | Trigger/ 83% |
|
| Procedure ground |
Table A.3 Control Cable Receptacle (8 Pin
PIN | Lead # | Function |
A | 41 | 42 VAC |
B | 42 | 42 VAC |
C | 2 | Output Control (trigger) |
D | 4 | Output Control (trigger) |
E | 21 | Work Sense Lead |
F | 75 | Remote Voltage Control |
G | 76 | Remote Voltage Control |
H | 77 | Remote Voltage Control |