Lincoln Electric IM910 manual Across the ARC Model, Figure B.1a

Page 17

B-3

OPERATION

B-3

CASE FRONT CONTROLS (See Figure B.1)

ACROSS THE ARC MODEL

1.WIRE FEED SPEED DISPLAY-The Wire Feed Speed display shows the rate the LN-15 will feed electrode dur- ing welding. The default WFS units for domestic models are inches/minute and can be changed to meters/minute through the configuration menu. The default WFS units for the European models are m/min. The wire feed speed is calibrated to within ±2%.

2.VOLTAGE DISPLAY-The voltage display shows the average arc voltage during the welding. A minus sign "-" appears when welding with electrode negative welding procedures. While welding, an LED will illuminate below the voltage display. After welding, the average voltage will continue to be shown for 5 seconds after the end and the LED will flash. of the weld. When not welding, the display shows "- - - ". The voltage is calibrated to ±2% over a range of 10 to 45 volts.

The voltage display is not a "preset" voltage. Refer to the examples from Figure B.1a.

3.WIRE FEED SPEED KNOB-The Wire Feed Speed knob is a 3-3/4 turn potentiometer that adjusts of the rate of feeding electrode. The wire feed speed range is 50 -

700inches/min (1.3 - 17.8 m/min)

FIGURE B.1a

4.VOLTAGE KNOB-The voltage knob is present only on control cable models.

Adjusting the voltage knob varies the power source volt- age to the LN-15. The value displayed is not a "preset" voltage. Only actual average arc voltage is shown on the voltage display.

For codes 10864, 10865:

The voltage knob controls the output of the power source through a 3-3/4 turn, 10K ohm potentiometer.

For codes 11033 and above:

The voltage knob controls the output of the power source through a _ turn, 10K ohm potentiometer.

5.TRIGGER CONNECTOR-5 Pin Receptacle is used to activate the Magnum Gun Switch.

6.CONNECTOR BUSHING-This connection is for weld- ing conductor cable assembly.

7.ON / OFF SWITCH-For codes 11033 and above:

The ON / OFF Switch turns power on and off to the wire feeder.

83% PROCEDURE

The LN-15 supports a special "dual procedure" mode. When activated, the wire feed speed is reduced to 83% of the set value, but no less than 50 inch- es/minute (1.27 m/min). The 83% procedure is most commonly used during pipe and out of position weld- ing. Requires Magnum 400 Dual Procedure Gun Equivalent.

FIGURE B.1

1 2

34

7

6

 

5

 

LN-15 CONTROL CABLE MODEL (CE)

Image 17
Contents Safety Depends on You LN-15 Wire FeederCalifornia Proposition 65 Warnings SafetyE C T R I C S H O C K c a n kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a L’Arc Précautions DE Sûreté60974-10 Safety Vii Table of Contents Technical Specifications LN-15 K1871-3 CE InstallationSafety Precautions InstallationLocation High Frequency ProtectionEngine Drive Power Source Connection Power Source ConnectionElectrode Connection Work ConnectionConnection DIAGRAM, Control 4INSTALLATIONA-4Guns and Cables Assemblies Electrode PolarityOnly qualified personnel should perform this operation Procedure to Install Drive Rolls and Wire GuidesFeeding Wire Electrode Operation Safety PrecautionsGeneral Description Figure B.1a Across the ARC ModelLN-15 POWER-UP Sequence Spring Tension ARM CV/CC ModeWFS Units Set the pressure arm as follows See Figure B.2aCold FEED/GAS Purge Switch Wire Drive ConfigurationFlow Meter Step Trigger Interlock SwitchSpindle Brake Shielding GAS ConnectionFigure B.3 Constant Current OperationFigure B.4 CC Wire Speed Setting Making a Weld Optional Equipment AccessoriesRoutine Maintenance MaintenancePeriodic Maintenance Calibration SpecificationHOW to USE Troubleshooting Guide TroubleshootingContact your local Lincoln Contact your local Lincoln Authorized Field Service FacilityYour local Lincoln Authorized Field Service FacilityFault Code Description Possible Adjustments Errors on the DisplayLN-15 DiagramsDimension Print LN-15 Control Cable Model CE Aviso DE Guards off