Lincoln Electric IM904 manual Select Suitable Location, Input Connections, Stacking, Tilting

Page 10

A-3

INSTALLATION

A-3

 

 

 

Read and understand entire Installation Section before starting installation.

WARNING

ELECTRIC SHOCK can kill.

Only qualified personnel should perform this installation.

Turn the input power OFF at the disconnect switch or fuse box before installing this equipment.

Turn the power switch on the Invertec STT “OFF” before connecting or discon- necting input power lines, output cables, or control cables.

Do not touch electrically hot parts.

Always connect the ground terminal to a good electrical earth ground.

SELECT SUITABLE LOCATION

Locate the machine where there is free circulation of clean air. Place the machine so that air can freely cir- culate into the sides and out of the rear of the machine. Dirt and dust that can be drawn into the machine should be kept to a minimum. Failure to observe these precautions can result in excessive operating temperatures and nuisance shut down of the INVERTEC STT II (CE).

This machine carries an enclosure rating of IP21S. It should not be placed in extremely damp or dirty loca- tions. It should not be exposed to rain or snow.

STACKING

The INVERTEC STT II (CE) cannot be stacked.

TILTING

Place the machine on a secure, level surface other- wise the unit may topple over.

MACHINE GROUNDING AND HIGH FREQUENCY INTERFERENCE PROTECTION

The machine may not be suitable for use in an envi- ronment where high frequency is present. For exam- ple do not place the machine in close proximity to “TIG” or “PLASMA” operations. To minimize high fre- quency interference:

Locate the STT II power source more than 15 feet (4.5 m) away from high frequency units and more than 25 feet (7.6 m) separation between ground connections or welding arcs of high frequency units.

Provide proper electrical ground to the machine per local and national electrical codes.

INPUT CONNECTIONS

FAILURE TO FOLLOW THESE INSTRUCTIONS CAN CAUSE IMMEDIATE FAILURE OF COMPO- NENTS WITHIN THE WELDER.

Turn the input power off at the disconnect switch before attempting to connect the input power lines.

Connect the green lead of the power cord to ground per local and national electrical codes.

SUPPLY CONNECTIONS

Be sure the voltage, phase, and frequency of the input supply is as specified on the rating plate. Input Power supply line entry in provided on the case back of the machine. See figure A.1 for location of the rating plate.

The INVERTEC STT II (CE) should be connected only by a qualified electrician. Installation should be made in accordance with local and national codes. Refer to the “Technical Specifications” at the beginning of this section for proper fuse sizes, ground wire, and input supply power cable sizes.

Some models come from the factory with an input power cord. If your model does not include the input power cord install the proper size input cable and ground cable according to “INPUT CABLE INSTALLA-

TION AND CONNECTION”.

INVERTEC STT II (CE)

Image 10
Contents Safety Depends on You Invertec S T T II CESafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications -INVERTEC STT II CE For CodeINPUT- Three Phase only Stacking Select Suitable LocationInput Connections TiltingInput Cable Installation and CON- Nection Ground ConnectionTo Operate at Procedure Input Voltage Reconnect ProcedureWire Feeder Output Connections Output ConnectionsOperating Instructions Safety PrecautionsOperation General WarningsWelding Capability Design Features and AdvantagesRecommended Equipment Operating ControlsPower Switch Turns output 3B. Peak Current Display Meter ThisWire Feeder Receptacle This is Auxiliary Power Circuit BreakerWelding Parameters and GUIDE- Lines Peak CurrentWelding Procedures for STT Accessories Options / AccessoriesLN-742 or STT-10 Wire Feeder Connection Instructions Figure C.3 STT-10 to STT II Connection Maintenance Input Filter Capacitor Discharge ProcedurePreventive Maintenance Troubleshooting HOW to USE Troubleshooting GuideRecommended Course of Action Problems Symptoms Possible CauseAuthorized Field Service FacilityProblems Possible Symptoms Cause Troubleshooting Troubleshooting Problems Symptoms Possible Cause Wiring Diagram Invertec STT II CE for Code Wiring Diagram Invertec STT II CE for Code DiagramsDimension Print STT II CE DIAGRAMSF-3Invertec STT II CE Invertec STT II CE Invertec STT II CE Precaucion Warnung