Lincoln Electric IM904 manual Installation, Technical Specifications -INVERTEC STT II CE For Code

Page 8

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS –INVERTEC STT II (CE) (For Code 11366)

INPUT- THREE PHASE ONLY

STANDARD VOLTAGE

INPUT CURRENT AT RATED OUTPUT

200/220/380/415/440/3/50/60 HZ

33/30/18/17/16

RATED OUTPUT

DUTY CYCLE

 

 

 

 

AMPS

 

 

VOLTS AT RATED AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

60% Duty Cycle

 

 

 

225

 

 

 

 

 

 

29

 

100% Duty Cycle

 

 

 

200

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CURRENT RANGE

 

OPEN CIRCUIT VOLTAGE

 

AUXILIARY POWER

 

 

 

 

 

 

 

 

 

 

 

 

Peak Current 1 0 - 450 Amps

 

 

85 VDC Maximum

 

115 2 VAC @ 4 Amps

Background

0 - 125 Amps

 

 

 

 

 

 

 

42 VAC @ 4 Amps

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RECOMMENDED INPUT WIRE AND FUSE SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INPUT VOLTAGE

 

FUSE(SUPER LAG)

INPUT AMPERE

 

TYPE 75°C

 

TYPE 75°C

AND FREQUENCY

 

OR BREAKER

 

RATING ON

 

COPPER

 

COPPER

 

 

SIZE

 

NAMEPLATE

 

SUPPLY WIRE

 

GROUND WIRE

 

 

 

 

 

 

 

 

 

 

IN CONDUIT

 

IN CONDUIT

 

 

 

 

 

 

 

 

 

 

AWG (IEC) SIZES

 

AWG (IEC) SIZES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200/50/60

 

40

 

 

 

33

 

 

 

 

 

 

 

220/50/60

 

40

 

 

 

30

 

 

10 (6 mm2)

 

10 (6 mm2)

380/50/60

 

30

 

 

 

18

 

 

 

 

 

 

 

415/50/60

 

30

 

 

 

17

 

 

 

 

 

 

 

440/50/60

 

30

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HEIGHT

WIDTH

 

 

 

DEPTH

 

 

 

 

WEIGHT

23.2 in

13.2 in.

 

 

 

24.4 in.

 

 

 

 

100 lbs.

589 mm

336 mm

 

 

620 mm

 

 

46 kg

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1At low input voltages (below 208 VAC) and input voltages of 380 VAC through 415 VAC there may be a 15% reduction in Peak Current.

2115 VAC not present on European Models.

INVERTEC STT II (CE)

Image 8
Contents Safety Depends on You Invertec S T T II CESafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications -INVERTEC STT II CE For CodeINPUT- Three Phase only Select Suitable Location Input ConnectionsStacking TiltingInput Cable Installation and CON- Nection Ground ConnectionInput Voltage Reconnect Procedure Wire Feeder Output ConnectionsTo Operate at Procedure Output ConnectionsSafety Precautions OperationOperating Instructions General WarningsDesign Features and Advantages Recommended EquipmentWelding Capability Operating ControlsPower Switch Turns output 3B. Peak Current Display Meter ThisWire Feeder Receptacle This is Auxiliary Power Circuit BreakerWelding Parameters and GUIDE- Lines Peak CurrentWelding Procedures for STT Accessories Options / AccessoriesLN-742 or STT-10 Wire Feeder Connection Instructions Figure C.3 STT-10 to STT II Connection Maintenance Input Filter Capacitor Discharge ProcedurePreventive Maintenance Troubleshooting HOW to USE Troubleshooting GuideProblems Symptoms Possible Cause Authorized Field ServiceRecommended Course of Action FacilityProblems Possible Symptoms Cause Troubleshooting Troubleshooting Problems Symptoms Possible Cause Wiring Diagram Invertec STT II CE for Code Wiring Diagram Invertec STT II CE for Code DiagramsDimension Print STT II CE DIAGRAMSF-3Invertec STT II CE Invertec STT II CE Invertec STT II CE Precaucion Warnung