Lincoln Electric IM904 manual Welding Procedures for STT

Page 18

B-6

OPERATION

B-6

 

 

 

WELDING PROCEDURES FOR STT II -

(Steel) Horizontal Fillet (See Table B.1 and B.2)

DIRECTION

 

OF

75°

TRAVEL

 

 

TOP VIEW

 

 

DIRECTION

 

45°

OF

75°

TRAVEL

 

 

END VIEW

 

FRONT VIEW

Table B.1

 

 

100% CO2 Gas Shield (Set for Steel Mode)

 

 

 

 

Plate Thickness “ (mm)

20 ga

14 ga

10 ga

 

(0.9)

(2.0)

(3.25)

Electrode size “ (mm)

0.035

0.045

0.045

 

(0.9)

(1.1)

(1.1)

WFS “/min (m/min)

100

100

170

 

(2.5)

(2.5)

(4.2)

Peak Current

220

260

280

Background Current

30

40

65

Tailout setting

3

7

5

Average Amperage

60

105

120

Travel Speed “/min

12

12

12

(m/min)

(0.3)

(0.3)

(0.3)

Gas Flow cfh (L/min)

 

25 (12)

 

Electrical Stickout “

 

1/4 - 3/8

 

(mm)

 

(6.4 - 10)

 

 

 

 

 

Table B.2

75% CO2 - 25% Ar Gas Shield (Set for Steel Mode)

Plate Thickness “ (mm)

20 ga

14 ga

10 ga

 

(0.9)

(2.0)

(3.25)

Electrode size “ (mm)

0.035

0.045

0.045

 

(0.9)

(1.1)

(1.1)

WFS “/min (m/min)

100

100

120

 

(2.5)

(2.5)

(3.0)

 

 

 

 

Peak Current

225

270

310

Background Current

40

65

70

Tailout setting

8

4

6

Average Amperage

70

110

130

Travel Speed “/min

12

12

12

(m/min)

(0.3)

(0.3)

(0.3)

Gas Flow cfh (L/min)

 

25 (12)

 

Electrical Stickout “

 

1/4 - 3/8

 

(mm)

 

(6.4 - 10)

 

 

 

 

 

(Stainless Steel) Horizontal Fillet

(See Table B.3 and B.4)

DIRECTION

 

OF

75°

TRAVEL

 

 

TOP VIEW

 

 

DIRECTION

 

45°

OF

75°

TRAVEL

 

 

END VIEW

 

FRONT VIEW

Table B.3

 

 

90% He, 7.5% Ar, 2.5% CO2

 

Gas Shield (Set for Steel Mode)

 

 

 

 

 

Plate Thickness “ (mm)

20 ga

14 ga

10 ga

 

(0.9)

(2.0)

(3.25)

Electrode size “ (mm)

0.035

0.045

0.045

 

(0.9)

(1.1)

(1.1)

WFS “/min (m/min)

100

130

170

 

(2.5)

(3.3)

(4.2)

 

 

 

 

Peak Current

165

210

250

Background Current

35

60

85

Tailout setting

7

7

4

Average Amperage

40

95

120

Travel Speed “/min

12

16

16

(m/min)

(0.3)

(0.4)

(0.4)

Gas Flow cfh (L/min)

 

25 (12)

 

Electrical Stickout “

 

1/4 - 3/8

 

(mm)

 

(6.4 - 10)

 

 

 

 

 

Table B.4

98% Ar, 2% O2

Gas Shield (Set for Stainless Steel Mode)

Plate Thickness “ (mm)

20 ga

14 ga

10 ga

 

(0.9)

(2.0)

(3.25)

Electrode size “ (mm)

0.035

0.045

0.045

 

(0.9)

(1.1)

(1.1)

WFS “/min (m/min)

100

130

170

 

(2.5)

(3.3)

(4.2)

 

 

 

 

Peak Current

145

190

280

Background Current

45

95

95

Tailout setting

7

8

7

Average Amperage

60

120

150

Travel Speed “/min

12

12

12

(m/min)

(0.3)

(0.3)

(0.3)

Gas Flow cfh (L/min)

 

25 (12)

 

Electrical Stickout “

 

1/4 - 3/8

 

(mm)

 

(6.4 - 10)

 

 

 

 

 

INVERTEC STT II (CE)

Image 18
Contents Safety Depends on You Invertec S T T II CESafety California Proposition 65 WarningsElectric Shock can kill Welding Sparks can cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Installation Technical Specifications -INVERTEC STT II CE For CodeINPUT- Three Phase only Stacking Select Suitable LocationInput Connections TiltingInput Cable Installation and CON- Nection Ground ConnectionTo Operate at Procedure Input Voltage Reconnect ProcedureWire Feeder Output Connections Output ConnectionsOperating Instructions Safety PrecautionsOperation General WarningsWelding Capability Design Features and AdvantagesRecommended Equipment Operating ControlsPower Switch Turns output 3B. Peak Current Display Meter ThisWire Feeder Receptacle This is Auxiliary Power Circuit BreakerWelding Parameters and GUIDE- Lines Peak CurrentWelding Procedures for STT Accessories Options / AccessoriesLN-742 or STT-10 Wire Feeder Connection Instructions Figure C.3 STT-10 to STT II Connection Maintenance Input Filter Capacitor Discharge ProcedurePreventive Maintenance Troubleshooting HOW to USE Troubleshooting GuideRecommended Course of Action Problems Symptoms Possible CauseAuthorized Field Service FacilityProblems Possible Symptoms Cause Troubleshooting Troubleshooting Problems Symptoms Possible Cause Wiring Diagram Invertec STT II CE for Code Wiring Diagram Invertec STT II CE for Code DiagramsDimension Print STT II CE DIAGRAMSF-3Invertec STT II CE Invertec STT II CE Invertec STT II CE Precaucion Warnung